Operation
be operated at least once a month for 10 minutes, with the
vehicle engine cold and at the lowest fan setting. The
heater should be checked annually by a qualified expert,
preferably prior to the heating season commencing.
be operated using the fuel specified on the name plate and
the rated voltage specified on the name plate.
Failure to follow the installation instructions and the notes
contained therein will lead to all liability being refused by
Webasto The same applies if repairs are carried out
incorrectly or with the use of parts other than genuine
spare parts. This will result in the revocation of the type
licence for the heater and therefore the General operating
licence / EC type licence.
Liability claims can only be made if the claimant can verify
that he has complied with the servicing and safety
instructions.
Before switching the heater on, set the vehicle heating system to the "warm" position
and the vehicle heater fan to the lowest setting (less power consumption)!
P/N LIT- UNASSIGNED 03/15/2007
Operating and
maintenance instructions
General Information
Maintenance and Safety Information
at filling stations and tank farms.
in locations where flammable vapours or dust may
accumulate (e.g. in the vicinity of fuel-, coal-, sawdust or
grain depots).
in enclosed spaces (e.g. garages). This should also be
considered when pre-setting heater operating times or
using the Telestart remote control.
Danger of explosions
and asphyxiation
!
Thermo 90 S/ 90 ST Webasto Product North America, Inc.
15083 North Rd. Fenton, MI. 48430
www.webasto.us & www.techwebasto.com
exposed to temperatures greater than +85°C. Exposure
to such temperatures may cause damage to the
electronic components.
operated without a minimum level of 20% of good quality
antifreeze in the water of the heating circuit.
The heater must not be:
The heater must be switched off:
The heater must:
Liability claims:
In the case of a severe build-up of smoke, unusual
combustion noises or fuel smell, the heater is to be put
out of operation by removing the fuse and may only be
restarted after being inspected by Webasto-trained
personnel.
General type approvals have been issued in the region covered by the European
Directive 70/156/EEC for the Thermo 90 S and Thermo 90 ST heaters, which comply
with Directives 2001/56/EC (Heating systems) and 72/245/EEC (EMC).
The installation of the units must be carried out in accordance with the installation
instructions. The installation must be checked in accordance with the Legal Provisions
for Installation. For details refer to the installation instructions.
The year of the initial operation must be durably marked on the heater's nameplate by
removing the non-applicable years.
Dear Webasto Customer !
We assume that the workshop / service center that carried out the installion explained to
you the operation and principle of functioning of your new heater to your complete
satisfaction. This owner's handbook is designed to give you a brief summary of how to
use the Thermo 90 S / Thermo 90 ST heaters.
Switching the
heater on
General
Switching the
heater off
Operation
Setting time/
day of the
week
Viewing
the time
Programming
heater starting
time
Recalling/
erasing preset
times
Programming
duration of
operating time
Setting the
remaining
operating time
Setting the
wakeup time
Recalling/
erasing the
wakeup time
Remote control
Manually: by pressing the button (continuous heating mode).
Automatically: by programming the heater starting time.
The standard digital timer enables you to preset the start of the
heater operation up to 7 days in advance.
It is possible to program 3 different starting times, only one of which
can be activated.
The standard digital timer features a wakeup alarm function.
When the ignition is switched on, the timer displays the current time
and the day of the week. When the heater is switched on, the display
and the buttons are illuminated.
After the power supply has been connected, all symbols on the
display will flash. The current time and weekday must be set.
The timer can be operated in that all flashing symbols can be
adjusted by means of the and buttons. If the buttons are not
pressed within 5 seconds, the time displayed will be stored. If the
and buttons are pressed for more than 2 seconds, the fast time -
setting mode is activated.
If the ignition is switched off while the heater is operating in the
continuous mode, the remaining operating time of 15 minutes is
displayed and the heater continues to operate for this period of time.
Manually: by pressing the button.
Automatically: after the programmed operating time has elapsed.
With the heater running: by programming the remaining operating
time.
Press the button for more than 2 seconds - time of the day is
flashing - and set the clock using the and buttons. Day of the
week is flashing - adjust the day of the week.
With the ignition switched off: press the button.
Press the button - the memory location is flashing - using the
and buttons set start of the heater operating time. Day of the week
is flashing - set the day of the week. By repeatedly pressing the
button, memory locations 2 and 3 can be programmed or the time
display mode can be reached.
Repeatedly press the button until the desired memory location is
displayed. To erase the preset time, press the button several
times until the time of the day is displayed instead of the memory.
The heater must be switched off. Press the button for 3 seconds -
operating time is flashing - and set the desired operating time
(10 to 120 minutes) using the and buttons.
Set the desired remaining operating time (1 to 120 minutes) using the
and buttons. The remaining operating time refers to the time
the heater still continues to remain in operation. It can only be
changed while the heater is in operation and the ignition switched off.
A wakeup time can only be programmed on the standard digital timer.
The wakeup time is not bound to a specific day of the week.
Repeatedly press the button until the bell symbol appears on
the display. Set the desired wakeup time using the and buttons.
The alarm clock turns off after 5 minutes or when one of the
buttons is pressed.
Repeatedly press the button until the bell symbol appears on
the display - read off wakeup time. To erase the wakeup time: press
the button until the bell symbol is no longer visible on the
display.
Possible by means of an optional external "instant heating" button.
day of the week heater "on" indicator
forward
Standard Timer
instant
heating
reverse
program
selection
time
alarm indicator
memory location
time display
2
MO
Standard Timer
Fault Code Display
Fault Codes on the Display of the Combination or Standard Digital Timer
Heater turns itself off automatically (=fault lock-out)
Troubleshooting
!
NOTE:
If the heater is activated by the switch, the types of malfunctions are indicated by
coded flashing signals via the operation indicator light during the after-run period of
the heater. The coded flashing signals correspond to the numbers in the table below:
No start-up (after 2 start-up attempts)
Flame extinguished
Undervoltage or overvoltage
Premature flame detection
Flame detector interruption or flame
detector short-circuit
Temperature sensor interruption or
temperature sensor short-circuit
Metering pump interruption or metering
pump short-circuit
Fan motor interruption or
fan motor short-circuit or
incorrect fan motor speed
Pencil-type glow plug interruption or
pencil-type glow plug short-circuit
Overheating
Circulating pump interruption or
circulation pump short circuit
F 01
F 02
F 03
F 04
F 05
F 06
F 07
F 08
F 09
F 10
F 11
After the occurrence of a malfunction, the fault is indicated on the display of the digital
timer if the heater is equipped with a standard digital timer.
Remedy
Cause
In the event of a malfunction, fuses and electrical connections should be checked for
proper condition and security.
If this action does not correct the defect, consult your authorized Webasto dealer.
After the heater has been shut down due to afault lock-out, a coded flashing signal is
emitted through the operation indicator during the after-run cycle of the heater. These
coded flashing signals are designed to assist the authorized Webasto dealer in isolating
the fault.
Combustion was not established
during start-up and start-up repetition
Flame goes out during operation
Switch heater off and then on again.
If the heater fails to re-start consult your
authorized Webasto dealer.
Heater overheats due to
lack/loss of coolant.
Top up coolant in accordance with the
vehicle manufacturer's instructions.
Voltage drop for more
than 20 seconds.
Check fuses, electrical connections and
battery.
Subject to change
Thermo 90 STThermo 90 S

Other manuals for Thermo 90 S

2

This manual suits for next models

1

Other Webasto Heater manuals

Webasto BlueHeat Thermo Top User manual

Webasto

Webasto BlueHeat Thermo Top User manual

Webasto Air Top 2000 ST D Installation and operating manual

Webasto

Webasto Air Top 2000 ST D Installation and operating manual

Webasto Thermo Top E Operator's manual

Webasto

Webasto Thermo Top E Operator's manual

Webasto Air Top 2000 User guide

Webasto

Webasto Air Top 2000 User guide

Webasto Thermo 90 ST User manual

Webasto

Webasto Thermo 90 ST User manual

Webasto Air Top 2000 D Installation and operating manual

Webasto

Webasto Air Top 2000 D Installation and operating manual

Webasto Air Top 2000 ST B User manual

Webasto

Webasto Air Top 2000 ST B User manual

Webasto thermo top evo User manual

Webasto

Webasto thermo top evo User manual

Webasto Air Top 5000 ST User manual

Webasto

Webasto Air Top 5000 ST User manual

Webasto Thermo 90 ST User manual

Webasto

Webasto Thermo 90 ST User manual

Webasto Dual Top Evo 6 User manual

Webasto

Webasto Dual Top Evo 6 User manual

Webasto Thermo Top E User manual

Webasto

Webasto Thermo Top E User manual

Webasto Air Top 3500 ST User manual

Webasto

Webasto Air Top 3500 ST User manual

Webasto Air Top 2000 ST B User manual

Webasto

Webasto Air Top 2000 ST B User manual

Webasto Air Top 3500 ST D User manual

Webasto

Webasto Air Top 3500 ST D User manual

Webasto Air Top 24 Instruction manual

Webasto

Webasto Air Top 24 Instruction manual

Webasto AirTop 2000 S User manual

Webasto

Webasto AirTop 2000 S User manual

Webasto Air Top Evo 40 Instruction manual

Webasto

Webasto Air Top Evo 40 Instruction manual

Webasto Air Top Evo 55 User manual

Webasto

Webasto Air Top Evo 55 User manual

Webasto DUAL TOP RHA-100 Instruction manual

Webasto

Webasto DUAL TOP RHA-100 Instruction manual

Webasto Coolant Guide

Webasto

Webasto Coolant Guide

Webasto Air Top 3500 ST User manual

Webasto

Webasto Air Top 3500 ST User manual

Webasto HL30 Instruction manual

Webasto

Webasto HL30 Instruction manual

Webasto Thermo Call TC2 COMFORT User manual

Webasto

Webasto Thermo Call TC2 COMFORT User manual

Popular Heater manuals by other brands

Johnson & Starley HI-SPEC J40 Installation, commissioning & servicing instructions

Johnson & Starley

Johnson & Starley HI-SPEC J40 Installation, commissioning & servicing instructions

BLACK DECKER BXFSH2000E manual

BLACK DECKER

BLACK DECKER BXFSH2000E manual

Warmtech WTCAC15-DU Original instructions

Warmtech

Warmtech WTCAC15-DU Original instructions

MALTEC CH7000DWB instruction manual

MALTEC

MALTEC CH7000DWB instruction manual

Heatwagon HVF110 instruction manual

Heatwagon

Heatwagon HVF110 instruction manual

Pur Line CHD222J user manual

Pur Line

Pur Line CHD222J user manual

SimTech KM-1720 manual

SimTech

SimTech KM-1720 manual

VOGEL&NOOT FULDA Assembly and operating manual

VOGEL&NOOT

VOGEL&NOOT FULDA Assembly and operating manual

MO-EL Fiore Use and maintenance

MO-EL

MO-EL Fiore Use and maintenance

MrHeater MH11BFLEX Operating instructions and owner's manual

MrHeater

MrHeater MH11BFLEX Operating instructions and owner's manual

MO-EL SHARKLITE 718 Use and maintenance

MO-EL

MO-EL SHARKLITE 718 Use and maintenance

Air King 8910 Important instructions & operating manual

Air King

Air King 8910 Important instructions & operating manual

MrHeater MHVFG30LP operating instructions

MrHeater

MrHeater MHVFG30LP operating instructions

BLACK DECKER BHDC500W46 instruction manual

BLACK DECKER

BLACK DECKER BHDC500W46 instruction manual

VOGEL&NOOT DION Installation

VOGEL&NOOT

VOGEL&NOOT DION Installation

Universal Blue UCRM9004-21 user manual

Universal Blue

Universal Blue UCRM9004-21 user manual

HydroQuip 8800 BP Series Installation & operation manual

HydroQuip

HydroQuip 8800 BP Series Installation & operation manual

MrHeater MH60CRFAV Operating instructions and owner's manual

MrHeater

MrHeater MH60CRFAV Operating instructions and owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.