WEBTEC HPM110 User manual

HPM110
Operation Manual / Bedienungsanleitung /
Manuel d’utilisation / Instrucciones de manejo

ENGLISH
2

ENGLISH
3
Table of contents
About this operating manual.........................................................5
1. Device description ...................................................................7
2. Safety instructions ...................................................................7
2.1 Intended use........................................................................... 9
2.2 Specialist personnel................................................................ 9
3. Layout and function ...............................................................10
3.1 Display.................................................................................. 12
3.2 Menu .................................................................................... 13
4. Operation ................................................................................15
4.1 Install the HPM110 ............................................................... 15
4.2 Switch on the HPM110......................................................... 15
4.3 Switch off the HPM110......................................................... 18
4.4 Switch the light on ................................................................ 18
4.5 Measure pressure peaks/display full scale value.................... 19
4.6 Delete MIN/MAX values......................................................... 19

ENGLISH
4
4.7 Correct the zero point ........................................................... 20
4.8 Set the measuring unit .......................................................... 21
4.9 Set automatic shutdown....................................................... 22
4.10 Set the display filter............................................................... 23
4.11 Delete saved measurement data (data logger version only) ... 24
4.12 Display serial number............................................................ 25
4.13 Set the date and time (data logger version only).................... 26
4.14 Record measurements (data logger version only) .................. 27
4.15 Change batteries .................................................................. 28
5. Troubleshooting .....................................................................30
6. Maintenance and cleaning ....................................................32
7. Disposal ..................................................................................33
8. Technical data ........................................................................35
8.1 Dimensional drawings and order numbers ............................ 38
8.2 Guidelines............................................................................. 43

ENGLISH
About this operating manual
5
About this operating manual
Before each work step, read the associated information carefully
and observe the specified order of instructions.
Pay particular attention to the chapter &„Safety instructions“
on page7 and follow the instructions.

ENGLISH
About this operating manual
6
Danger signs and symbols used
NOTE
This symbol indicates dangers that can cause material damage.
►Follow the instructions to avoid danger!
This symbol indicates dangers in handling the HPM110
SR-HPM-110-MT/SR-HPM-110-UN.
►Follow the instructions to avoid the dangers!
&Here you will find a reference to other sections, docu-
ments or sources.
■Here you will find lists.
►Here you will find handling instructions.
1Here you will find action steps.
ÄHere you will find feedback.

ENGLISH
Device description
7
1. Device description
The HPM110 SR-HPM-110-MT/SR-HPM-110-UN, hereinafter referred
to as HPM110, is used to measure pressure. Dynamic pressure peaks
are measured at a sampling rate of 10 ms (100 measured values/sec-
ond). The MIN/MAX memory is continuously updated and overwritten.
Scope of delivery and accessories
Check the scope of delivery and the accessories ordered. If anything is
missing, contact your sales office.
■HPM110 SR-HPM-110-MT with adapter M16x2 or
HPM110 SR-HPM-110-UN without adapter
■Mini USB cable (data logger version only)
2. Safety instructions
Before working with the HPM110, read and follow this operating man-
ual. Disregarding the instructions, especially the safety information, can
result in danger to people, the environment, equipment and the system.
The HPM110 corresponds to the current state of the art in terms of
accuracy, functionality and safe operation of the devices.

ENGLISH
Safety instructions
8
Observe the existing national regulations for accident pre-
vention and safety at work when carrying out any work!
Observe the IP protection class when using the HPM110
in wet areas (&„Technical data“ on page77)!
The HPM110 should only be connected by trained spe-
cialist personnel!
Note the specified tightening torques!
Avoid any violent impacts on the HPM110!
Never use a damaged or defective HPM110!
Never assemble or disassemble the HPM110 while the
HPM110 is under pressure!
Only use the HPM110 in the approved pressure range
(&„Technical data“ on page77)!

ENGLISH
Safety instructions
9
2.1 Intended use
The HPM110 is intended for pressure measurement within the ap-
proved ranges (&„Technical data“ on page77) .
Any other use of the HPM110 is inadmissible, can lead to accidents or
the destruction of the HPM110 and immediately renders any guarantee
and warranty claims against the manufacturer null and void.
Misuse
The HPM110 does not comply with Directive 2014/34/EU and there-
fore must not be used in potentially explosive areas.
2.2 Specialist personnel
This operating manual is intended for trained specialist personnel who
are familiar with the applicable provisions and standards in the area of
use. The qualified personnel responsible for commissioning and oper-
ating the device must be suitably qualified. Such qualification can be
obtained through training or appropriate instruction.
The contents of this operating manual must be known to the specialist
personnel and accessible at all times.

ENGLISH
Layout and function
10
3. Layout and function
1
6
2
3
5
4

ENGLISH
Layout and function
11
①REC display, flashes when data recording is active*
②MIN/MAX or FullScale display, depending on the setting
③Battery level indicator
④Actual value display
⑤Bar graph with peak and hold functions
⑥Mini-USB port*
ON/OFF
key
Switch device on/off.
Press for 2 s: Switch on the backlight for
20 s.
MIN/MAX/FS
key
Select additional display value: Decrement
MIN, MAX or FS/time*.
Press for 2 s: Set the time (CSV format-
ting)*.
ZERO/MENU
key
Zero point adjustment/increment time*.
Press for 2 s: Open the menu.
RESET/OK/
START-STOP
key
Delete MIN and MAX values from the
memory.
Confirm menu functions.
Press for 2 s: Start/stop measurement*.
*- data logger version only

ENGLISH
Layout and function
12
3.1 Display
The HPM110 is screwed into an existing system and measures the
current pressure value. The current pressure (ACTUAL) is shown on the
display. The measured value is shown in the actual value display with
the appropriate unit. The MIN, MAX or FS value is shown in the lower
area of the display.
Display Description
Bar graph Displays the current pressure in graphical form.
Displays pressure peaks in the form of a pixel (line).
The display is updated at an interval of 50 ms (20
measurements/s).
Actual value Displays the actual pressure.
The display is updated at an interval of 300 ms (3
displays/s).
MIN/MAX Displays the MIN, MAX or FS value, depending on
the setting.
The display is updated at an interval of 300 ms (3
displays/s).
FS Full scale value (e.g. 600 bar).
Units Displays the set unit.

ENGLISH
Layout and function
13
Display Description
Battery Displays the battery status (5 segments).
REC Flashes when data logging is active (only with data
logger version)
x10 Display value (actual value display and MIN/MAX
display) x10.
3.2 Menu
The following settings are configured in the menu:
■Switch automatic shutdown on/off
■Set the measuring unit (bar, mbar, PSI, kPa, MPa)
■Adjust filter setting (damping)
■Delete saved measurement data (data logger version only)
■Display serial number
Press the ZERO/MENU key for 2 s to activate the menu.
Press the ZERO/MENU key again to select the next function.
Press the RESET/OK/START-STOP key to save the function - the
HPM110 switches to the actual value display.

ENGLISH
Layout and function
14

ENGLISH
Operation
15
4. Operation
4.1 Install the HPM110
NOTIFICATION
Material damage due to excessive force.
►Only ever hand-tighten the HPM110 (together with the pre-in-
stalled adapter)!
►If you operate the HPM110 SR-HPM-110-MT without an
adapter, maintain the permitted tightening torque of 35 Nm.
1 Mount the HPM110 in the desired position using the pre-in-
stalled adapter.
4.2 Switch on the HPM110
The HPM110 is supplied from the factory with built-in batteries.
1 Press the ON/OFF key.
ÄThe HPM110 starts and carries out a self-test.
ÄThe current settings are displayed one after the other.

ENGLISH
Operation
16
Execution of the self-test.
Display of the measuring range (FS)
in bar.
Number of saved measurements
(data logger version only)

ENGLISH
Operation
17
Auto power-off function active.
Automatic shutdown after 5 min.
The function can be changed in the
menu.
Serial number and software version
Actual value display mode

ENGLISH
Operation
18
4.3 Switch off the HPM110
1 Press the ON/OFF key.
ÄThe HPM110 is switched off.
4.4 Switch the light on
1 Keep the ON/OFF key pressed for 2 s.
ÄThe backlight of the display is switched on for 20 s.

ENGLISH
Operation
19
4.5 Measure pressure peaks/display full scale value
■The MIN/MAX function is used to measure pressure peaks.
■The display of the full scale value (FS) helps make the bar graph
function easier to read.
The smallest (MIN) or the largest (MAX) measured values are stored
in the MIN/MAX memory. The MIN/MAX memory is deleted when the
device is switched off. If different pressure tests are to be carried out in
succession, the MIN/MAX memory must be deleted after each meas-
urement.
1 Press the MIN/MAX/FS key to switch between the display
values.
ÄThe currently selected display value (MIN, MAX or FS) is
shown on the display.
4.6 Delete MIN/MAX values
1 Press the RESET/OK/START-STOP key.
ÄThe MIN and MAX values are reset.

ENGLISH
Operation
20
4.7 Correct the zero point
In the event of undesirable deviations in a depressurised state (atmos-
pheric pressure), the zero point can be corrected manually.
■The zero point correction can only be carried out for deviations up
to a maximum of 5% of the full scale value.
■Always carry out the zero point correction in a depressurised state
to avoid incorrect measurements.
1 Press the ZERO/MENU key.
ÄThe zero point is reset and ZERO ON appears in the dis-
play.
2 Press the RESET/OK/START-STOP key.
Ä0.0 bar appears as the actual value on the display. The
adjustment remains activated until the device is switched
off.