Version UM.G5.PWS
USER MANUAL
DOOR DETECTOR G5 SERIES
WITH POWER SUPPLY
INSTALLATION INSTRUCTIONS
Please ask us about our range of fixings clips and brackets.
Ensure that both the receiver and the transmitter are at the same level.
Securely fix the transmitter and receiver to the car/car doors through
the fixing holes with the bolts provided, ensuring that the labels are
pointing outwards.
Fix the power supply on the car top. Ensure that the steel cover is grounded.
Connect the power supply to the input terminals. Connect the output signals to
the output terminals.
Connect the cables from the receiver and the transmitter to the input terminals
of the door controller. Ensure that both cables can be easily and smoothly bent.
Tightly lock both sides of the intermediate connectors.
Switch on the power.
The yellow LED in the receiver will light up.
The red LED in the receiver will light up when the light beams are interrupted.
1.
2.
3.
4.
5.
6.
Neither LED in the receiver is lit.
Both the yellow and red LEDs of the door
detector are lit without interruption
between the RX and TX.
The plastic filter is too dirty.
Other infrared equipment is nearby.
The ambient light is stronger than allowed.
There is a system fault.
I LED si accendono correttamente
quando vengono interrotti, ma la
porta di cabina non si apre.
Wrong connection with NC/NO contacts.
The output relay is broken.
Check the wiring.
The green LED in the power supply
is not lit.
The power supply wires are broken or
incorrectly connected.
The terminal connection is too loose.
The power supply is broken and needs
to be replaced.
The cable is broken or not connected.
· Keep connection cables away from high voltage and/or high current wires.
· Keep connection cables away from door motor and door drive.
· Avoid direct sunlight or other infrared ingress to the receiver (RX).
· Prior to power-on, clean the lenses with a soft, damp cloth.
· Do not bend or twist the edges, and do not scratch the lenses.
PLANNED MAINTENANCE PROCEDURE
· Ensure that the yellow LED is lit (system functioning), then clean the lense with a soft,
damp cloth.
· Check all plug and terminal connections.
· Perform a detection test by inserting an object greater than 50mm between the TX
and RX.
· The red LED status indicator will light to confirm object detection.
NOTES AND ADVICE
TROUBLESHOOTING
Power Supply LEDs Door Detector LEDs
SW1 ON
SW2
OFF
SW3
SW4
ON OFF
ON OFF
ON OFF
Buzzer on Buzzer off
Delay 20s Delay 30s
Infinite 60s
Intermittent Costant
Buzzer functions
Buzzer delay
Buzzer active
Buzzer setting
Buzzer Function
POWER SUPPLY
AC/DC
567
+-
NC NO COM
4
1 2 3
03.G5.PWS.FED.24AD
11-35VDC
03.G5.PWS.FED.24AD
MODEL NO.
DC INPUT VOLTAGE
10-24VAC
AC INPUT VOLTAGE
Status
PACKING LIST
Power supply
Cables
Transmitter (TX)
Receiver (RX)
Operation manual
Mounting accessories
1
2 cavi
1
1
1 copia
1 kit
Please check if anything is missing
from the packing list.
Contents may slightly according to
the customers specific requirements.
· This equipment should be installed by qualified technicians.
· Follow the instruction of this manual.
· Do not drill the PCB.
[email protected] www.wecoitaly.com
WARNING
MADE IN P.R. CHINA

Other Weco Security Sensor manuals

Weco 03.G5.PWS.KAP.110 User manual

Weco

Weco 03.G5.PWS.KAP.110 User manual

Weco UPF Series User manual

Weco

Weco UPF Series User manual

Weco CDZ Series User manual

Weco

Weco CDZ Series User manual

Weco CDZ Series User manual

Weco

Weco CDZ Series User manual

Weco SIL 2 User manual

Weco

Weco SIL 2 User manual

Weco G5 Series User manual

Weco

Weco G5 Series User manual

Popular Security Sensor manuals by other brands

Niko Multi CLS-DALI-3 Basic quick guide

Niko

Niko Multi CLS-DALI-3 Basic quick guide

Hytronik HCD418-DH Installation and instruction manual

Hytronik

Hytronik HCD418-DH Installation and instruction manual

Optex VX Infinity Series installation instructions

Optex

Optex VX Infinity Series installation instructions

IMS E3TA Series instruction manual

IMS

IMS E3TA Series instruction manual

Blaupunkt CO-S1 quick start guide

Blaupunkt

Blaupunkt CO-S1 quick start guide

CPS Leak-Seeker II Operation manual

CPS

CPS Leak-Seeker II Operation manual

Amptek X-123 user manual

Amptek

Amptek X-123 user manual

LG 14HK701G-W owner's manual

LG

LG 14HK701G-W owner's manual

DSC Digital ENCORE EC-300DP installation instructions

DSC

DSC Digital ENCORE EC-300DP installation instructions

ENGO CONTROLS DOOR EDOORZB quick guide

ENGO CONTROLS

ENGO CONTROLS DOOR EDOORZB quick guide

Visonic TOWER CAM PG2 installation instructions

Visonic

Visonic TOWER CAM PG2 installation instructions

PCB Piezotronics 233B Installation and operating manual

PCB Piezotronics

PCB Piezotronics 233B Installation and operating manual

HomeMatic HmIP-SMI Mounting instruction and operating manual

HomeMatic

HomeMatic HmIP-SMI Mounting instruction and operating manual

Mini Gadgets CDRFAD user manual

Mini Gadgets

Mini Gadgets CDRFAD user manual

Force PRO Series instruction manual

Force

Force PRO Series instruction manual

Alarmtech GD 335 instruction manual

Alarmtech

Alarmtech GD 335 instruction manual

Algo 2506 Configuration manual

Algo

Algo 2506 Configuration manual

Diablo DSP-7LP manual

Diablo

Diablo DSP-7LP manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.