1 Introduction
Ethernet Security Routers from eidmüller are designed for industrial applications and
fitted with a robust housing. To ensure reliable, error-free operation, and to prevent
damage or injury, please read the operating instructions, all safety information provided
in this document and any other safety information that were supplied with the product.
2 Safety notice
The device heats up during operation. Allow the unit to cool down or use
protection gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the
product label. Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low
Voltage Directive 2014/35/EU and 2014/30/E
U
.
Installation, commissioning and maintenance may only be performed by
qualified electricians.
Observe the operating instructions.
Indoor use and pollution degree II, it must be wiped with a dry cloth for
clean up the device and label.
o Utilisation en intérieur et degré de pollution II, il faut l'essuyer avec un
chiffon sec pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
o Ne bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
o Si l’appareil est utilise d’une maniere non specifiee par le fabricant, la
protection qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient
temperature is not exceed 75 degrees C.
o Doit être monté dans le panneau de commande industriel et la
température ambiante ne doit pas
dépasser 75 degrés C
.
Intended use
The device is intended for the realization of communication networks within an industrial environment,
it is intended to be used in a restricted access location. The device may only be used within the scope
of the specified technical data. The device is intended to be mounted to a well-grounded mounting
surface, such as a metal panel. Any other use may result in unintentional malfunction and damage.
Observing the documentation is part of the intended use.
Environmental conditions
This equipment is intended to be used in a restricted access location.
hen planning the installation site make sure that the ambient temperature during operation will not
exceed the temperature given in the technical data.
Also make sure that the air flow will not be compromised by other devices.
Ensure that the mounted and wired device is not exposed to any mechanical stress.
FCC compliance
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
3 Package Checklist
Your package is shipped with the following items:
1 x Router 2 x LTE Antenna (LTE/4G model)
1 x Hardware Installation Guide (printed) 1 x SIM card adapter set (nano/micro)
1 x 3-Pin Terminal connector 2 x Dust caps for RJ45 ports
1 x 4-Pin Terminal connector 1 x all mounting kit
1 x LAN Antenna 3 x Dust caps for antenna ports
1 x Screw tool packet
4 Panel Layouts
1. 4-Pin Terminal block power input P R1 / P R2
2. Grounding screw / Frame ground (Note: The
shielding ground of LAN and AN port is
electrically connected to the grounding screw)
3. PoE Indicator (powered via PoE)
4. Power input LEDs (P R1 / P R2)
5. LAN port Link/Activity LED
6. AN port Link/Activity LED
7. LAN Link/Activity LED
8. LTE/4G Connection Status LED (only LTE/4G
models)
9. Digital I/O ports Status LEDs (ON/OFF)
10. LAN antenna connector (RP-SMA female)
11. Terminal block for Digital Input and Output
12. Reset Button
13. AN Port 10/100Base-T(X)
14. LAN port 10/100Base-T(X) / PoE P D
15. Serial Port (RS 232 connector)
16. LEDs TX/RX Status of Serial Port
17. Article Number
18. Slot for 2 SIM Cards with format Mini SIM (only
LTE/4G models)
19. Main Antenna LTE/4G Interface (SMA-female)
20. AUX Antenna LTE/4G Interface (SMA-female)
21. DIN-rail Clip
5 Mounting Dimensions
(units = mm)
6 DIN-Rail Mounting
Slide the device onto DIN-rail and make sure that the Din-rail clip clicks into the rail firmly.
STEP 1: Place the mounting clip from
above onto the mounting rail.
STEP 2: Press the device against the DIN
rail until the fastening element engages on
the mounting rail.
To remove the Ethernet Switch from the
DIN-rail pull down the latch with a
screwdriver then move the device away from the DIN rail and lift it up.
7 Grounding
ATTENTION
- Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
- Do the ground connection from the ground screw to the grounding
surface prior to connecting devices.
- This product is intended to be mounted to a well-grounded mounting
surface, such as a metal panel.
- The shielding ground of the RJ45 ports are electrically connected to the
ground connection (screw).
8 SIM card installation (LTE/4G models)
- Ensure that the device is
powered-off.
- Remove cover from SIM card slot
on top of the housing.
- Insert SIM card(s) with Mini format
as illustrated.
Note: For using SIM cards with format
Nano or Micro use a frame from
attached SIM card adapter set.

4 5 6 V1.3 / 2022-08-24
9 Wiring Redundant Power Inputs and DI / DO
The Router supports redundant power supply inputs and provides 1 digital input and 1
digital output. Refer to illustration below for correct wiring.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
o Tenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24A G. Torque
value 4.5 lb-in.
o Le bornier est compatible avec les connecteurs et convient pour 12-
24A G. Valeur de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than
105°C.
o La température de service nominale du câble d’entrée doit être
supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201
power supply only.
o Fourni par la source SELV évaluée uniquement par l'alimentation UL
61010
-
1 or 61010
-
2
-
201.
Power Wiring Wiring DI / DO
10 Communication Connections
Dependent on the model the Routers are equipped with:
1 x LAN Port (10/100Base-T(X) / Auto MDI-X, PoE Powered Device)
1 x AN Port (10/100Base-T(X) / Auto MDI-X)
1 x LAN Interface IEE802.11 b/g/n
1 x Serial Interface (DB9 connector)
1 x Digital Input / 1 x Digital Output
1 x Cellular Interface (only LTE/4G models)
Please use for RJ45-Ports only cables suitable for the respective type of communication
and ensure that signals are protected from possible interference.
10 1 10/100Base T(X) RJ45 Ports
The 10/100BaseT(X) ports are used to connect to Ethernet-enabled devices. Below
table shows pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) ports.
Auto MDI-X ensures that both wiring-schemes are supported (Automatic crossover).
10/100Base T(X) RJ45 Pinouts
MDI Port Pinouts
MDI
-
X Port Pinouts
8
-
pin RJ45
Pin
Signal
Pin
Signal
1
Tx+
1
Rx+
2
Tx
-
2
Rx
-
3
Rx+
3
Tx+
6
Rx
-
6
Tx
-
10 2 Serial Interface DB-9 Connector
Pinouts DB-9 Connector (male)
11 Management Access (Login to Web Interface)
By factory default, the Router only can be accessed by HTTPS-secured eb interface
via the wired LAN Port All other access modes (HTTP, Telnet, SSH) and any access
from other interfaces are not allowed by default.
Web interface Access (HTTPS):
IP Address: 192 168 1 110 / 255 255 255 0
Username: admin
Password: Weidmueller
Connect the PC to wired LAN port and configure the PC’s IP address to a free one of
range 192.168.1.0 / 255.255.255.0. Start a web browser and enter the IP address into
the browser’s address line (https://192.168.1.110). After prompt appearance enter
username and password. After confirmation with "OK" the home page will be displayed.
12 Factory Default Settings
LAN port: 192.168.1.110 / 255.255.255.0 (static)
AN port: DHCP
ireless LAN: Disabled
Mobile Interface: Disabled (only available for LTE/4G models)
Username: admin
Password: eidmueller
eb Access: HTTPS via LAN port
13 Reset Button
● Pressing < 5 seconds: Reboots the device ( arm Start) and sets IP of LAN port to
Factory Default IP.
● Pressing >= 5 seconds: Resets the device completely to factory default settings.
14 LED Indicators
Description of Router’s front panel LED indicators:
LED
Color
Status
Description
PWR1
Green
On
Power is being supplied to power input PWR1.
PWR2
Green
On
Power is being supplied to power input PWR2.
Po
Green
On
The device is powered via Po
.
LAN / WAN Green
On
LAN/WAN Port
Link / Activity L D
Blinking
Data is transmitted.
WLAN
Green
On
Linked to a Wireless network (Client Mode)
Green
Blinking
Operating in mode Access Point
LT /4G
Green
On
Mobile connection established (Online)
DI / DO Green
On
Input / Output
status set to logical 1
Off
Input / Output status set to logical 0
15 Disposal Information
Observe the notes for proper disposal of the
product. You can find the notes here:
www.weidmueller.com/disposal.
16 Specifications (Overview)
Technology
Ethernet Standards
IEEE 802.3 for 10BASE-T
IEEE 802.3u for 100BASE-TX
IEEE 802.3af for Power-over-Ethernet
IEEE 802.11b/g/n for ireless LAN
Interfaces
RJ45 Ports 10/100BASE-T(X) auto negotiation speed, F/H duplex
mode and auto MDI/MDI
-
X connection
Serial
Port
1x DB9 connector
Cellular Interface 2G (GSM / GPRS / EGPRS / EDGE), 3G ( CDMA /
HSDPA / HSUPA
), 4G/
LTE
LAN Interface
IEEE802.11b/g
/
n
SIM
-
Card slots
2x
Mini
-
SIM (ID
-
000 format)
Connector for antennas 1x RP-SMA female
2x SMA female (LTE/4G models only)
DI/DO
(Dry Contact)
1x DI (1: 5~30V, 0: 0~2V), 1x DO (Max
.
: 30V / 20 mA)
LED Indicators
P R1, P R2, PoE (active), LAN/ AN Port Link /
Activity, LAN Link, LTE/4G Link, DI / DO Status; Serial
Port Data Transmitting
Power
supply
Input Voltage
24 V DC (12 to 48 V DC), 2 redundant inputs
or 48 V DC Power-over-Ethernet on LAN Port
(IEEE802.3af
compli
a
nt)
Input
Power
5.5 (typical)
Connection One removable 4-pin terminal block, iring cable 12-
24A G
Overload Current Protect
ion
Present
Reverse Polarity Protect
ion
Present
Physical Characteristics
Housing
IP30 protection, metal
Dimension ( x H x D)
45
x
95
x
8
1
mm (
1
.
77
x
3
.
74
x
3
.
1
9
inch)
eight
395
g
Installation
DIN
-
rail
Environmental conditions
Operating Temperature
-
25
to
7
0
°C
(
-
13
to
1
58
°F)
Storage Temperature
-
40 to 85°C (
-
40 to 185°F)
Ambient Relative Humidity
5 to 95%
(non
-
condensing)
Altitude
up to 2000 m
Regulatory Approvals
Safety
UL 61010
-
1
;
UL 61010
-
2
-
201
;
EN 62311
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD
IEC 61000-4-3 RS
IEC 61000-4-4 EFT
IEC 61000-4-5 Surge
IEC
61000
-
4
-
6 CS
Radio EN 301 489-1/-17; EN 300 328, EN 301 511;
EN 301 908
-
1
Shock
IEC 60068
-
2
-
27
Free Fall
IEC 60068
-
2
-
31
Vibration
IEC 60068
-
2
-
6
MTBF
Time
IE-SR-2TX- L: 381.084 hrs
IE-SR-2TX- L-4G-EU: 355.921 hrs
IE
-
SR
-
2TX
-
L
-
4G
-
U
S
:
353.679 hrs
Database
Telcordia SR332
Warranty
Time Period
5 years
Contact Information
eidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com
Pin # RS-232
(DT Device)
RS-422 RS-485(4-
wire)
RS-485 (2-wire)
1
DCD
TX
-
TX
-
DATA
-
2
RXD
TX+
TX+
DATA+
3
TXD
RX+
RX+
---
4
DTR
RX
-
RX
-
---
5
GND
GND
GND
GND
6
DSR
---
---
---
7
RTS
---
---
---
8
CTS
---
---
---
9
RI
---
---
---
This manual suits for next models
5
Other Weidmüller Network Router manuals

Weidmüller
Weidmüller IE-SW-AL10M-8TX-2GC Manual

Weidmüller
Weidmüller 2682250000 Manual

Weidmüller
Weidmüller IE-SW-EL16-16TX Manual

Weidmüller
Weidmüller IE-SW-AL18M-16TX-2GC Manual

Weidmüller
Weidmüller IE-SW-AL14M-12GT-2GESFP Manual

Weidmüller
Weidmüller IE-SW-AL16M-16TX Manual

Weidmüller
Weidmüller IE-SW-AL08M-6TX-2GT Manual