Hardware Installation Guide
Managed Fast/Gigabit Ethernet Switch
IE-SW-AL10M-8TX-2GC (Part No. 2740420000)
1. Introduction
Ethernet Switches from Weidmüller are designed for industrial applications and fitted with a robust
housing. To ensure reliable, error-free operation, and to prevent damage or injury, please read the
operating instructions, all safety information provided in this document and any other safety
information that were supplied with the product.
2. Safety notice
The device heats up during operation. Allow the unit to cool down or use protection
gloves when carrying out any work.
The device may only be connected to the supply voltage shown on the product label.
Higher voltage than specified will destroy the device.
The device must be supplied by a SELV source as defined in the Low Voltage
Directive 2014/35/EU and 2014/30/EU.
Installation, commissioning and maintenance may only be performed by qualified
electricians.
Observe the operating instructions.

Indoor use and pollution degree II, it must be wiped with a dry cloth for clean up
the device and label.
oUtilisation en intérieur et degré de pollution II, il faut l'essuyer avec un chiffon sec
pour nettoyer l'appareil et son étiquette.
Do not block air ventilation holes.
oNe bouchez pas les orifices de ventilation.
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
oSi l’appareil est utilise d’une maniere non specifiee par le fabricant, la protection
qu’il apporte peut se voir diminuee.
Shall be mounted in the Industrial Control Panel and ambient temperature is not
exceed 75 degrees C.
oDoit être monté dans le panneau de commande industriel et la température
ambiante ne doit pas dépasser 75 degrés C.
Intended use: The device is intended for the realization of communication networks within an
industrial environment, it is intended to be used in a restricted access location. The device may
only be used within the scope of the specified technical data. The device is intended to be mounted
to a well-grounded mounting surface, such as a metal panel. Any other use may result in
unintentional malfunction and damage. Observing the documentation is part of the intended use.
Environmental conditions: This equipment is intended to be used in a restricted access location.
When planning the installation site make sure that the ambient temperature during operation will
not exceed the temperature given in the technical data. Also make sure that the air flow will not be
compromised by other devices. Ensure that the mounted and wired device is not exposed to any
mechanical stress.
FCC compliance: This device complies with part 15 of FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
3. Package Checklist
Your Ethernet Switch is shipped with the following items:
Ethernet Switch
Hardware Installation Guide (printed)
6-Pin Terminal connector
Serial console cable
Protective caps for RJ45 ports and SFP ports
4. Panel Layouts
1. Terminal block for power input PWR1/PWR2
and failure relay for power and port link loss
(output)
2. Grounding screw / Frame ground (Note: The
shielding ground of the LAN port is
electrically connected to the grounding
screw)
3. Power input LEDs (PWR1 / PWR2)
4. Ring Master Status LED
5. Ring Status LED
6. Fault LED (PWR1/PWR2 fault or port link
loss)
7. Serial Console Port (RS232)
8. Reset Button
9. Link/Activity LED 10/100Base-T(X) ports
10. Duplex mode LED 10/100Base-T(X) ports
(Amber = Full Duplex, OFF=Half Duplex, Off
= Collisions)
11. Article Number
12. Gigabit Combo Port (100/1000BASE-X SFP
slot / 10/100/1000BASE-T(X) port)
13. Link/Activity LEDs for Gigabit Combo Ports
G1/G2 (for an inserted SFP transceiver)
14. Link/Activity LED 10/100/1000BASE-T(X)
port
15. Port Speed LED 10/100/1000BASE-T(X) port
16. 10/100BASE-T(X) ports
17. DIN-rail kit
5. DIN-Rail Mounting
Slide the switch onto a DIN-rail and make sure that the switch’s Din-rail clip clicks into
the rail firmly.
STEP 1: Place the mounting clip from
above onto the mounting rail.
STEP 2: Press the device against the
DIN rail until the fastening element
engages on the mounting rail.
To remove the Ethernet Switch from
the DIN-rail pull down the latch with a
screwdriver then move the device
away from the DIN rail and lift it up.
6. Mounting Dimensions (units = mm)
7. Grounding Ethernet Switch
ATTENTION
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI).
the ground connection from the ground screw to the grounding surface prior to
connecting devices.
This product is intended to be mounted to a well-grounded mounting surface, such as
a metal panel.
The shielding ground of the RJ45 ports are electrically connected to the ground
connection (screw).
8. Wiring Redundant Power Inputs and Fault Alarm Relay
The switch supports redundant power supply inputs and provides a fault alarm relay for
detecting the user-configurable failure events
Interruption of Power 1 or Power 2 and
Link Loss of Ethernet Ports.
Refer to illustration below for correct wiring.
Warning / Avertissement
Take into consideration the following guidelines before wiring the device
oTenez compte des directrices suivantes avant de câbler l’appareil.
Terminal block is mating with Plug and suitable for 12-24AWG. Torque value 4.5 lb-in.
oLe bornier est compatible avec les connecteurs et convient pour 12-24AWG. Valeur
de couple 4,5 lb-in.
The temperature rating of the input connection cable should higher than 105°C.
oLa température de service nominale du câble d’entrée doit être supérieure à 105 °C.
Supplied by SELV source evaluated by UL 61010-1 or 61010-2-201 power supply
only.
oFourni par la source SELV évaluée uniquement par l'alimentation UL 61010-1 or
61010-2-201.
4 5 6 V1.1 / 2020-12-29
Note about behavior of failure relay (triggerable by power failure or port link
down):
Relay contact is closed if the device is powered-off.
Relay contact is open if the device is powered-on and no alarm conditions exist (neither
Power Failure Alarms nor Port Link Loss Alarms are activated (Web menu Warnings 
Fault Relay Alarm).
Relay contact closes if any of an activated alarm condition happens.
9. Communication Connections
Switch IE-SW-AL10M-8TX-2GC is equipped with following communication interfaces:
8 x 10/100BASE-T(X) ports
2 x Ethernet-Combo-Ports, that can be used either as 10/100/1000BASE-T(X) ports or
alternatively as 100/1000BASE-X ports with respective SFP Transceivers
Please only use cables suitable for the respective type of communication and ensure that signals are
protected from possible interference.
9.1 10/100BASE-T(X) RJ45 Ports
The 10/100BaseT(X) ports located on Ethernet Switch’s front panel are used to connect to Ethernet-
enabled devices. Below we show pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-
type) ports. Auto MDI-X ensures that both wiring-schemes are supported (Automatic crossover
function).
10/100BASE-T(X) RJ45 Pinouts
MDI Port Pinouts
MDI
-
X Port Pinouts
8
-
pin RJ45
Pin Signal Pin Signal
1 Tx+ 1 Rx+
2 Tx- 2 Rx-
3 Rx+ 3 Tx+
6 Rx- 6 Tx-
9.2 Combo-Ports
The switch is equipped with combo ports that can be used either as 10/100/1000Base-T(X) ports
with RJ45 connector or with optional SFP transceivers (mini GBIC) for 100/1000Base-X (e.g. for
connections with fiber optic technology over long distances). For correct function, please note that
only one function of a combo port may be used and connected at a time. The RJ45 port can only be
used if no SFP module is plugged in.
9.2.1 1000BASE-T Ethernet Port Connection
1000BASE-T data is transmitted on differential TRD+/- signal pairs over copper wires.
Pin Signal
1 TRD(0)+
2 TRD(0)-
3 TRD(1)+
4 TRD(2)+
5 TRD(2)-
6 TRD(1)-
7 TRD(3)+
8 TRD(3)-
9.2.2 100/1000BASE-X SFP fiber optic port
The 100/1000BaseSFP type slots require either a 100BaseSFP or a 1000BaseSFP fiber
transceiver (mini-GBIC) to work properly. Please only use SFP modules and cables that are
compatible with each other to establish an optical connection.
LC-Port Pinouts: LC-Port to LC-Port Cable Wiring:
For a LC-Port with separate Transmit and Receive Port please remember to connect the Tx
(transmit) port of Device-1 to the Rx (receive) port of Device-2, and the Rx (receive) port of Device-
1 to the Tx (transmit) port of Device-2.
9.3 RS232 Console Port
The RS232 Interface with RJ45 connector can be used to access the switch console for
configuration.
Pinouts Serial
Console Port:
10. User Management
10.1 Device Access (Login to Web Interface)
The Web interface of the Switch can be accessed via following factory default settings:
IP address / Netmask: 192.168.1.110 / 255.255.255.0
User name: admin
Password: Detmold
Connect the PC to any Ethernet port of the managed Switch and set the PC’s IP
address to a free one of range 192.168.1.0 / 255.255.255.0
Start a web browser and enter the IP address of the connected Switch into the
browser’s address line (http://192.168.1.110). After the appearance of prompt (login)
enter the login credentials. After confirmation of your input with "OK" the home page of
the switch will be displayed.
Note: For more detailed information about configuration and use of the device features
please read the downloadable manual from Weidmüller’s website (Product catalogue 
Automation & Software Industrial Ethernet Advanced Line managed Switches 
Select Product Click and expand section „Downloads“ Download needed software
or documentation).
10.2 Reset Button
Press reset button for 2 to 3 seconds to reboot the switch (Warm Start).
Press reset button for >= 5 seconds to reset the switch to factory default settings.
11. LED Indicators
The front panel of the Ethernet Switch contains several LED indicators. The function of
each LED is described in the table below.
LED Color Status Description
PWR1 Green On Power supplied to power input PWR1.
PWR2 Green On Power supplied to power input PWR2.
R-MSTR
(Ring Master) Green On Is Ring Master of an enabled O-Ring.
Ring Green On O-Ring redundancy is enabled.
Blinking Ring structure is broken (No redundancy).
FAULT Amber On Fault Relay indication for Power failure
and Port link loss.
LNK/ACT
(Ports 1 - 8) Green
On Port’s link is active.
Off Port’s link is inactive.
Blinking Data is transmitted.
Full / Half
Duplex
(Ports 1 - 8)
Amber
On Port is set to Full Duplex Mode.
Off Port is set to Half Duplex Mode.
Blinking Packet collisions detected.
LNK/ACT
RJ45 Combo
Port G1/G2
Green
ON Port’s link is active.
OFF Port’s link is inactive.
10/100/1000M
RJ45 Combo
Ports G1/G2
Amber
On Port speed is 100 Mbps
Off Port speed is 10 or 1000 Mbps
LNK/ACT 100/
1000Base-X
Combo Ports
G1/G2
Green
On Port’s fiber link is active.
Off Port’s fiber link is inactive.
12. Specifications
Technology
Ethernet Standards
IEEE 802.3 for 10BASE-T
IEEE 802.3u for 100BASE-TX and 100BASE-FX
IEEE 802.3ab for 1000BASE-T
IEEE 802.3z for 1000BASE-X
IEEE 802.3x for flow control
IEEE 802.3ad for port trunk with LACP
IEEE 802.1D for STP (Spanning Tree protocol)
IEEE 802.1w for RSTP (Rapid Spanning Tree protocol)
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1X for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
Processing Type Store and Forward
MAC Table size 8K
Packet buffer size 1 Mbit
Backplane bandwidth 5.6 Gbps
Interfaces
RJ45 Ports 8 x 10/100BASE-T(X) auto negotiation speed, F/H duplex
mode and auto MDI/MDI-X connection
Combo Ports (RJ45/SFP) 2 x 10/100/1000BaseT(X) or 100/1000BaseSFP
RS232 Console Port RS232 Interface with RJ45 connector for Console access
LED Indicators PWR1, PWR2 (Power), Fault (Relay), Ring Master, Ring
Status, Port Link/Activity/Speed, Port Full/Half Duplex Mode
Relay Contact Max. 1A @ 24 V DC
Power Supply
Input Voltage 24 V DC (12 - 48 V DC), 2 redundant inputs
Input Current 0.9 A @ 12 V DC
0.45 A @ 24 V DC
0.2 A @ 48 V DC
Connection One removable 6-pin terminal block, Wiring cable 12-24AWG
Overload Current Protect. Present
Reverse Polarity Protect. Present
Physical Characteristics
Housing IP30 protection, metal
Dimension (W x H x D) 74.3 x 153.6 x 107.5 mm (2.93 x 6.05 x 4.2 inch)
Weight 1140 g
Installation DIN-rail
Environmental conditions
Operating Temperature -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity 5 to 95% (non-condensing)
Operating Altitude Up to 2000 m
Regulatory Approvals
Safety UL 61010-1; UL 61010-2-201
EMC
EN 55032, EN 55024, FCC Part 15 Subpart B Class A,
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV,
IEC 61000-4-3 RS: 80 MHz to 1 Ghz: 3 V/m,
IEC 61000-4-4 EFT: Power: 0.5 kV; Signal: 0.5 kV,
IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV,
IEC 61000-4-6 CS: 3 Vrms
Shock IEC 60068-2-27
Free Fall IEC 60068-2-31
Vibration IEC 60068-2-6
MTBF
Time 366.529 hrs
Database Telcordia SR332
Warranty
Time Period 5 years
Contact Information
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26, 32758 Detmold / Germany
Phone +49 (0) 5231 14-0, Fax +49 (0) 5231 14-292083
E-Mail weidmueller@weidmueller.com, Internet www.weidmueller.com

This manual suits for next models

1

Other Weidmüller Network Router manuals

Weidmüller IE-SW-AL18M-16TX-2GC Manual

Weidmüller

Weidmüller IE-SW-AL18M-16TX-2GC Manual

Weidmüller IE-SW-AL14M-12GT-2GESFP Manual

Weidmüller

Weidmüller IE-SW-AL14M-12GT-2GESFP Manual

Weidmüller IE-SR-2TX-WL Manual

Weidmüller

Weidmüller IE-SR-2TX-WL Manual

Weidmüller IE-SW-AL16M-16TX Manual

Weidmüller

Weidmüller IE-SW-AL16M-16TX Manual

Weidmüller IE-SW-AL08M-6TX-2GT Manual

Weidmüller

Weidmüller IE-SW-AL08M-6TX-2GT Manual

Weidmüller 2682250000 Manual

Weidmüller

Weidmüller 2682250000 Manual

Weidmüller IE-SW-EL16-16TX Manual

Weidmüller

Weidmüller IE-SW-EL16-16TX Manual

Popular Network Router manuals by other brands

Tenda TE-D305 user guide

Tenda

Tenda TE-D305 user guide

D-Link DSL-526B user guide

D-Link

D-Link DSL-526B user guide

Juniper PTX1000 quick start guide

Juniper

Juniper PTX1000 quick start guide

ZyXEL Communications WAH3004 quick start guide

ZyXEL Communications

ZyXEL Communications WAH3004 quick start guide

Nortel Secure Router 4134 Installation

Nortel

Nortel Secure Router 4134 Installation

Asus RT-AC88U quick start guide

Asus

Asus RT-AC88U quick start guide

Billion BiPAC 711C2 user manual

Billion

Billion BiPAC 711C2 user manual

Asus RT-AC68U quick start guide

Asus

Asus RT-AC68U quick start guide

Allied Telesis AR100 series user guide

Allied Telesis

Allied Telesis AR100 series user guide

Icidu NI-707532 manual

Icidu

Icidu NI-707532 manual

Asus RT-N65R quick start guide

Asus

Asus RT-N65R quick start guide

ZyXEL Communications Prestige 480 user guide

ZyXEL Communications

ZyXEL Communications Prestige 480 user guide

Linksys R 72 user guide

Linksys

Linksys R 72 user guide

JR ProPo PCM9XII instruction manual

JR ProPo

JR ProPo PCM9XII instruction manual

Maipu S2000-8/16 10/100Mbps Ethernet Switch user manual

Maipu

Maipu S2000-8/16 10/100Mbps Ethernet Switch user manual

B&B Electronics EIR618 Series quick start guide

B&B Electronics

B&B Electronics EIR618 Series quick start guide

ZyXEL Communications IES-1000 - ANNEXE 7 user guide

ZyXEL Communications

ZyXEL Communications IES-1000 - ANNEXE 7 user guide

Cisco ASR 920 series Configuration guide ethernet router

Cisco

Cisco ASR 920 series Configuration guide ethernet router

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.