WEISS ER12D-1 Installation instructions

Product Code: ER12D-1
INSTALLATION/OPERATION INSTRUCTIONS Single Speed Heat Transfer
HEAT TRANSFER CONTROLLER FOR USE WITH SINGLE SPEED FAN
Increase key : adjust
temperature and value
Setting key
Decrease key : adjust
temperature and value
Turn ON/OFF
For your safety please follow the installation and operating instructions

© COPYRIGHT Weiss Ltd 2020. All rights reserved
Weiss Limited reserves the right to alter designs and specifications
without notice and without obligation
ER12D-1
Revision 01.0 170620
GENERAL USE AND SAFETY INFORMATION
Thank you for purchasing this quality DIGITAL HEAT TRANSFER CONTROLLER by Weiss.
This digital controller has been designed to ensure highly effective transfer of heated air throughout your
home. The large screen is designed for easy and straightforward setup of your heat transfer system, using a
high precision built-in sensor with custom sensing algorithm to accurately determine room temperature and
improve system stability.
NOTE: THESE UPDATED INSTALLATION AND OPERATION INSTRUCTIONS SUPERSEDE ANY INSTRUCTIONS ON THE
CARTON or other FITTING INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE COMMENCING INSTALLATION.
Note: Pictures and diagrams on packaging are designed only to be used as a concept. All installation
details should be carried out as per the instructions herein.
Note:THIS PRODUCT MUST BE WIRED BY A REGISTERED ELECTRICIAN
SUITABILITY
The controller constantly monitors the room and set temperatures. When the heat source provides heat to
the room and raises the room temperature above the set temperature, the controller will detect this increase
and turn the fan on.
BEFORE YOU START
Weiss DIGITAL HEAT TRANSFER CONTROLLER must not be mounted in areas subject to direct splashing. Refer
to New Zealand standard NZECP2: 1988 Section 4.6 and Australian Standard AS3000:1991, Section 6.2.
SAFETY NOTE
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
To avoid a hazard, a damaged supply cord must be replaced by the manufacturer. This includes the
removal of the supply cord as this appliance is supplied as compliant. Modification including removal of
the plug or cutting of the supply cord (fitted to any motor) will render the unit NON-COMPLIANT.
INSTALLATION INFORMATION
IMPORTANT
Selecting the mounting location
•The controller is for internal use only.
•Mount approx. 1.5 metres above the floor on an inner wall near the heat source.
•The controller must be placed within the same room as the heat source.
•Avoid locations which are not affected by the heat source, e.g. other side of the room or around a
corner.
•Do not mount on hot surfaces or surfaces exposed to direct sunlight.
FOR OPTIMUM PERFORMANCE –Installation Instructions
1. Open the controller by placing your thumb on the bottom edge of the thermostat unit and using
your other fingers to apply pressure to the rear portion of the unit. Sliding the rear portion toward
your thumb will expose the mounting holes.
2. Choose a mounting position on the wall and cut a 64 mm diameter hole in the wall gib,
avoiding any structure timber framing or wiring contained behind.
3. See Wiring Diagram below to connect the fan.
4. After connecting the required wiring, mount the base of the controller with the 2 screws, noting the
direction of the display is correct.
5. Reconnect the interconnect cable to the display front.

© COPYRIGHT Weiss Ltd 2020. All rights reserved
Weiss Limited reserves the right to alter designs and specifications
without notice and without obligation
ER12D-1
Revision 01.0 170620
6. Replace the cover by placing over the metal clips located on the base and slide in a downward
direction. Note: Do not use excessive force to fit the cover.
HOW TO CONNECT UP A WEISS ER12D-1 DIGITAL CONTROLLER
1. The LIVE line in is connected to terminal 1 (L) at the rear of the control unit.
2. Neutral connections are common to terminal 2 (N).
3. The LIVE line out to the fan unit is terminal 3 (HI).
4. The controller is then set to the temperature that is required to be maintained in the room with the
main heat source (the room with the controller) using the up and down arrows to modify the smaller
number (top right of display).
Note: Approximate means of disconnection are required to be incorporated in the fixed wiring. This product
must be installed by a registered Electrician.
Display information
Power OFF System is Off. The fan will be switched off and the controller switches to standby mode.
Set Minimum Room Temperature –The controller adjusts the heat transfer rate according to the set
temperature. Adjust the set temperature using the Adjust Up and Down buttons.
Mode As a Heat Transfer specific controller, this controller is locked into Heat Transfer mode
and cannot be switched to an alternative mode.
The advanced settings below are for reference only, and are ordinarily not required as the unit is factory
pre-set for heat transfer.
ADVANCED CONTROLLER FUNCTIONS (NOT NORMALLY USED)
Entering Advanced set-up
•Turn off your controller with the Power Off button.
•Press and hold the Fan Indicator button for 5 seconds.
•Switch between set-up screens using the Fan indicator button
•Adjust using the Up and Down buttons
•Press the Power Off button to return to the home screen
•The controller will turn off after 5 seconds of no activity in programming mode
Advanced set-up screens
1. A1 - Temperature calibration: adjust with the Adjust Up and Down buttons
2. A2 - Lock the controller –Set “0” Half lock, “1” Full lock & “2” Cancel (after 10min & will display)
3. To unlock the controller press and hold the Down button for 5 seconds.
4. A3 - Minimum operating temperature (1-25°C): default value 5°C
`
`
5. A4 - Maximum operating temperature (30-70℃): default value 35°C
6. AB - Return to Factory Default Setting –(Display A o, Long Press Fan Key to Return to Factory Default
Setting)

© COPYRIGHT Weiss Ltd 2020. All rights reserved
Weiss Limited reserves the right to alter designs and specifications
without notice and without obligation
ER12D-1
Revision 01.0 170620
COMPLIANCE AND WARRANTY INFORMATION
•This appliance must be installed by a registered electrician in accordance with the relevant electrical
wiring rules and regulations and a COC is required for a warranty claim.
•Heat Transfer units are Not for use with a heat pump
•Do not cover the fan unit with any insulation material
•Do not completely close off adjustable outlet vents
•Always install this product with the supplied controller
•Weiss Limited reserves the right to alter designs and specifications without notice
•Incorrect wiring or installation is not covered by warranty
•Full Warranty information is available on our web site: https://www.weiss.co.nz/warranty
QUESTIONS AND ANSWERS
Can I place the controller in a different room from the fireplace/heat source?
No. The controller must be mounted in the same room as your heat source. Make sure that the controller is
in a position where it can easily detect changes in the room temperature from your heat source, e.g. 2-4
metres away from the heat source. Do not place the controller in the hallway or near the doorway, around
a corner from the heat source, or far away (>6 metres) from the heat source in a large room.
How far away from the heat source should I place the fan?
You should keep at least 1.5 metres of distance between the heat source extraction point and the fan.
However, the recommended distance between the extraction point and the fan is 3 metres.
IMPORTANT NOTES
Troubleshooting: The control panel has built-in error detection and may display the following faults:
Sensor fault will display and“E1”and“E2”.
E1: Sensor short circuit alarm
E2: Sensor open circuit alarm
When temperature higher than 55℃displays “HI”
When temperature lower than 0℃displays “LO”
Technical Specifications
Set Temperature Range: 5 - 35°C
Temperature Resolution: 0.5°C
Operating Voltage/Frequency: 220V 50/60Hz
Sensing Element: NTC
Operating Temperature: 0 to 50ºC
Approval: All relevant AS/NZS standards
EMC Approval: All relevant AS/NZS standards
•The unit should be checked annually for correct operation.
•This controller has been designed to work with Weiss Heat Transfer AC Fans only.
Weiss Limited, 20b Arwen Place, East Tamaki
PO Box 204-120 Highbrook Auckland
New Zealand
Web: www.weiss.co.nz
Table of contents
Other WEISS Controllers manuals
Popular Controllers manuals by other brands

Bristan
Bristan Wave Single Outlet Touchpad Installation instructions and user guide

CBS ArcSafe
CBS ArcSafe RSK-CS01W instruction manual

Honeywell
Honeywell 190887-EET installation guide

Graco
Graco PRECISIONMIX 231-119 Instructions-parts list

Trane
Trane Tracer VV550 Installation

Morningstar
Morningstar ProStar PS-15M-48V Operator's manual