WEJOIN SCB02 User manual

I
DC Variable-Frequency 3D Barrier Gate
SCB02 (DC24V)
Manual
V1.0.1

I
Preface
Symbol Stipulations
The meanings of the following symbols which may appear in this manual
Symbols
Meanings
Indicates that there is a high level of potential danger, if not
avoided, it may cause casualties or serious injures.
Indicates that there is a medium or low level of potential
danger. If not avoided, it may cause minor or moderate
injury to personnel.
Indicates potential risks. If you ignore the information, it
may cause equipment damage, data loss, equipment
performance degradation, or unpredictable results.
Indicates that it can help you solve a problem or save your
time.
Indicates that it is the additional information of the main
text, which emphasizes and supplements the main text.
Revision Records
Version No.
Revision Content
Release Date
V1.0.0
First Release
2022.02
Safety Instructions
The following is the correct methods of using the product, in order to prevent danger, prevent
property damage, etc., please read this manual carefully before using the equipment and strictly
follow it during use. Please keep the manual properly after reading.
Operating Environment Requirements
Please transport, use and store the device within the allowable humidity and temperature range.
Please do not let any liquid flow into the device.
Please install the device in a well-ventilated place, and do not block the vents of the device.
Please do not press hard, vibrate violently or soak the equipment.
Please use the factory packaging or materials of the same quality when shipping the equipment.
It is recommended to ground via the grounding hole on the device to improve the reliability.
Operation and Maintenance Requirements
Please do not disassemble the device privately.
Please use the accessories or attachments of the manufacturer for installation and maintenance by
professional service personnel.
Please do not provide two or more power supply methods to the device at the same time, otherwise
the device may be damaged.
The self-contained boom is not allowed to be lengthened or cut off, and it is also not allowed to add
weight to the boom privately.

Contents
Preface..........................................................................................................I
Safety Instructions........................................................................................I
1. Production Overview................................................................................1
1.1. Functions and Features......................................................................1
1.2. Technical Data...................................................................................1
2. Product Structure......................................................................................1
2.1. Mechanism Structure.........................................................................2
2.2. Running Direction Setting.................................................................3
3. Cabinet Installation...................................................................................3
4. Controller Explanations and Instructions.................................................3
4.1. Controller Interface Explanations......................................................4
4.2. Controller Parameter Setting of Master Motor..................................6
4.3. “Regular Menu” Command List of Master Motor.............................6
4.4. “Advanced Menu” Command List of Master Motor.......................12
4.5. Controller Parameter Setting of Slave Motor..................................15
4.6. “Regular Menu” Command List of Slave Motor.............................16
4.7. “Regular Menu” Command Explanation.........................................17
4.8. “Advanced Menu” Command List of Slave Motor.........................19
4.9. “Advanced Menu” Command Explanation.....................................20
5. Common Malfunctions and Solutions....................................................21
6. Warranty and Service Items....................................................................23
7. Maintenance............................................................................................24
8. Packing List............................................................................................24

1
1. Production Overview
1.1. Functions and Features
1.1.1. Adopting the three-dimensional double-drive no-spring mechanism
independently developed.
1.1.2. Dual power motors, use two-stage planetary gear and two-stage gear drive
combination respectively, rotate up and down and horizontally, and superimpose to
form a three-dimensional surface running track.
1.1.3. Adopting DC permanent magnet synchronous motor and variable-frequency
control, effectively solve the problems of limited speed, life and spring.
1.1.4. Breaking the normal operation mode of the barrier gate, the starting point
adopts the same-direction driving operation mode with the vehicle passing, to realize
the ultra-high-speed and ultra-intensive operation.
1.1.5. The boom will be reset after hit and removed, which effectively protects the
boom and the mechanism, alarm against abnormal lifting boom.
1.1.6. Be able to stop at any position in three-dimensional space, no longer limited
height problem.
1.1.7. Double protection, one drive failure will not affect the other drive, and the
barrier gate can still operate in another space;
1.1.8. No spring design, no longer worry about configuring springs and springs
broken.
1.1.9. Traffic lights on the top cover to better indicate the passage of vehicles.
1.1.10. The running direction can be easily changed in two steps.
1.1.11 The cabinet is round hollow-out design, with smooth lines and intuitive
movement process.
1.1.12. Equipped with carbon fiber foam round boom, to effectively protect the
vehicle.
1.1.13. Large LCD screen display, English visual menu, easy function selection and
debugging.
1.1.14. Support external radar, coil, infrared anti-smashing function, built-in DC 12V
power output, can be used for external radar power supply.
1.1.15. Support RS485 communication or RS485 off-line connection.
1.1.16. DC12V power supply is optional.
1.2. Technical Data
1.2.1. Working temperature (motor): -35℃~ + 70℃
1.2.2. Power supply input voltage: AC110±10%, AC220V±10%

2
1.2.3. Controller input voltage: DC24V±10%, 10A
1.2.4. Motor power: up and down power 180W; horizontal power 60W
1.2.5. Relative Humidity: 30%~80%, No condensation
1.2.6. Distance of remote control: L≥30M
1.2.7. Running Speed: 0.3 seconds MAX
1.2.8. MTBF: 8,000,000 times
2. Product Structure
2.1. Mechanism Structure

3
2.2. Running Direction Setting
3. Cabinet Installation
According to the specific conditions of the site, select the barrier gate of the
appropriate specification, and use the expansion bolts to fix the cabinet on the ground
with 4 sets M16*150 expansion bolts. At the location where the cabinet is installed,
the barrier foundation should be made according to the site conditions, and the
cast-in-place foundation should be made for the non-concrete ground.
4. Controller Explanations and Instructions
All the electrical connections are done before delivery. The necessity is to connect the
power and grounding connection.

4
4.1. Controller Interface Explanations
Item
Explanation
Wire Control
Interface
This interface is available for parking system, also available for
external controller to control barrier gate.
UP: Short circuit “UP” and “GND”
Down: Short circuit “Down” and “GND”
Stop: Short circuit “Stop” and “GND”

5
Item
Explanation
Anti-smashing
Interface
Infrared Photocell: boom will lift up when short circuiting
“Infrared photocell interface” and “GND” during boom down.
Loop Detector: boom will lift up when short circuiting “loop
detector interface” and “GND” during boom down; in up limit
position, boom will fall down automatically after these two
interfaces disconnected.
RS485
communication
interface
It is used for controlling the barrier gate or checking the status of
the barrier gate by computer or system; also used for online
controlling the paired barrier gates synchronously.
Limit Relay
Output
Interface
It is used for the system to checking the status of the barrier gate
by the opening and closing times; users can also change to other
output modes via option 4 of the advanced menu.
DC12V Power
Output
Provide 1A current output, available for radar or small light strips.
Interface for
R&G lights
Available to connect with R&G lights, to indicate the working
status of the barrier gate.
Buttons of
Mater Motor
The 4 buttons have two working status: normal working status
and menu setting status, the function of normal working status is
that “▲” is the opening function, “▼” is the closing function, (in
normal working status of slave motor also link-able to open and
close), “■” is the stopping function, “ 三” is the setting function
which is invalid when it is short pressed under normal working
status; Long press “ 三” for 2 seconds to enter the menu setting
status. In the menu setting status, “▲” and “▼” are used to adjust
menu items or parameters, “■” is to cancel the set value or exit
the menu setting status, “ 三” is used to enter the next menu or
save the set value. (Note: These buttons can only set the menu of
master motor)

6
Item
Explanation
Buttons of
Slave Motor
The 4 buttons have two working status: normal working status
and menu setting status, the function of normal working status is
that “▲/+” is the opening function, “▼/-” is the closing function,
“■QUIT” is the stopping function, “ ” is the setting function
which is invalid when it is short pressed under normal working
status; Long press “ ” for 2 seconds to enter the menu setting
status. In the menu setting status, “▲/+” and “▼/-” are used to
adjust menu items or parameters, “■QUIT” is to cancel the set
value or exit the menu setting status, “ ” is used to enter the
next menu or save the set value. (Note: These buttons can only set
the menu of slave motor)
LCD Screen
It is used to display the information of the master motor of the
barrier gate, such as the working status, parameters, menu items.
LED Digital
Tube
It is used to display the information of the slave motor of the
barrier gate, such as the working status, parameters, menu items.
4.2. Controller Parameter Setting of Master Motor
Long press “三” button for 2 seconds to enter the regular menu setting status. Select
menu items by short press or long press "▲" and "▼" buttons, short press once to
increase or decrease by one, long press to continuously increase or decrease. When
the required diameter displayed by the LCD, press “ 三” button again to enter the
setting of the specified item, and press the "■" to return to the previous level or exit
the setting. When the specified parameter setting is completed, you must press "三"
button to confirm it to take effect. The currently set parameters is invalid if pressing "
■" button.
The recommended range specifically refers to the 2m carbon fiber boom.
4.3. "Regular Menu" Command List of Master Motor
4.3.1. Opening operation parameters
Sub-menu
Defaults
Range
Recommended
Values
Remarks
1.1 Acceleration Time
3
1-20
≥3
The smaller the
value, the faster the
speed

7
1.2 Opening Speed
100
15-100
90-100
The bigger the
value, the faster the
opening speed
1.3 Deceleration Angle
65
10-80
60-70
The angle at which
deceleration begins
in the opening
process; if the boom
shakes after it is
opened in place,
users can reduce this
value.
1.4 Angle of Low-speed
Area
90
45-90
90
The angle at which
the boom enters a
low-speed area in
the opening process;
if the boom shakes
after it is opened in
place, users can
reduce this value.
1.5 End Speed
8
1-50
6-8
The minimum speed
at which the barrier
gate is opened in
place; if the boom
shakes after it is
opened in place,
users can reduce this
value.
1.6 Learning Speed
25
10-50
25
The speed at which
the the barrier gate
begins to learn the
up limit position
after the power is
turned on for the
first time.
4.3.2. Closing operation parameters

8
Sub-menu
Defaults
Range
Recommended
Values
Remarks
2.1 Acceleration Time
1
1-20
1-3
The smaller the
value, the faster the
speed
2.2 Closing Speed
100
15-100
90-100
The bigger the
value, the faster the
opening speed
2.3 Deceleration Angle
35
10-80
33-38
The angle at which
deceleration begins
in the closing
process; if the boom
shakes after it is
closed in place,
users can increase
this value.
2.4 Angle of Low-speed
Area
0
0-45
0
The angle at which
the boom enters a
low-speed area in
the closing process;
if the boom shakes
after it is closed in
place, users can
reduce this value.
2.5 End Speed
4
1-50
2-5
The minimum speed
at which the barrier
gate is closed in
place; if the boom
shakes after it is
closed in place,
users can reduce this
value.
2.6 Learning Speed
25
10-50
25
The speed at which
the the barrier gate
begins to learn the
down limit position
after the power is

9
turned on for the
first time.
1.3 The Deceleration Angle
It is used to set the angle at which deceleration begins in the opening process. The
angle is 0 degree when the barrier gate is opened in place(in horizontal position)
and 90 degrees when it is closed in place(in vertical position). This parameter
indicates that deceleration begins when the barrier gate is opened to this angle. If
the boom shakes after it is opened in place, users can reduce this value. (Chapter
2.3 has the similar operation)
1.4 The Angle of Low-speed Area
It is used to set a low-speed area in the opening process. When the opening angle
reaches the set angle, the barrier gate will run at the end speed that chapter 1.5 set
until it is opened in place. If the value is 90, the function is invalid. If the boom
shakes after it is opened in place, users can reduce this value appropriately.
(Chapter 2.4 has the similar operation)
1.5 The End Speed
This is the minimum speed at which the barrier gate is opened in place. The barrier
gate will run at the this speed until it is opened in place. If the parameter is set too
large, the boom will shake when it is opened in place. (Chapter 2.5 has the similar
operation)
4.3.3. Quick operation parameter
Sub-menu
Model Type
Remarks
Auto setting of opening and closing
operating parameter according to
different models
SCB02
Quickly set parameters
according to different
models
Notice: this device can quickly set the opening and closing operating parameters
according to the model types, which shorten the debugging time. If the effect is still

10
not good after setting, you can adjust the corresponding parameters appropriately.
4.3.4. Position setting
Sub-menu
Range
Model Type
Remarks
4.1
Position
learning
mode
Find up and down
limit/ find up limit
only/ find down limit
only
Find up limit
only
Learning mode after the
power is turned on for the
first time.For straight boom
which is over 5 meters long
or fence boom, it is
recommended to select the
"Find up limit only" mode;
when the barrier gate is
installed under an eaves,
please select the "Find
down limit only" mode.
4.2
Manual
learning f
up and
down
Limit
None; operate
according to the
prompts on the screen.
In manual mode, learn the
up and down limit.
4.3
Manual
learning of
up limit
None; operate
according to the
prompts on the screen.
In manual mode, learn the
up limit only.
4.4
Manual
learning of
down limit
None; operate
according to the
prompts on the screen.
In manual mode, learn the
down limit only.
4.5
Horizontal
fine
adjustment
1-3000
275-290
Boom horizontal fine
adjustment
4.6
Vertical
fine
adjustment
1-3000
2-8
Boom vertical fine
adjustment

11
Tip: When modifying the opening and closing indents, pay attention to observe
whether the position of the limit pressure bar and the limit adjusting bolt is sufficient,
and use a 4mm Allen wrench to adjust the position of the bolt appropriately.
4.3.5. Remote controller learning
Sub-menu
Remarks
5.1 How to match
code
Press the setting button to enter the learning state of the remote
controller, and press any buttons of the remote controller to
learn. Users can learn up to 60 remote controllers
5.2 How to clear
code
Press the Setting button to invert the color of the +- symbol on
the screen, and press ▲ and ▼ at the same time to clear the
code of all remote controllers.
4.3.6. RS485 setting
Sub-menu
Defaults
Range
Remarks
6.1 Address
1
0-255
When RS485 is online, the host is set
to 0, and the slave is set to 1. When it
is connected to the host computer,
1-255 can be set.
6.2 Baud Rate
19200
9600/19200
19200 baud rate is a multi-functional
communication protocol; 9600 is
compatible with the protocol of old
DZ5 control board.
Notice: please contact the manufacturer for detailed communication protocol.
4.3.7. Auto-closing function
Defaults
Range
Remarks
OFF
0-255, 0 is OFF
auto-closing time when no vehicle is passing. Unit:

12
second.
Notice: when no loop detector or radar is installed, this function can be used for
auto-closing. It can also be used with counting function to prevent the situation that
the barrier gate is not closed because of over-counting.
4.3.8. Counting function
Defaults
Range
Remarks
OFF
OFF-ON
store the times of opening signal, and the barrier
gate will be auto closed when the number of the
leaving vehicles is the same as the number of the
opening signal.
4.3.9. Sensitivity of auto-reversing on obstacle
Defaults
Range
Remarks
100
50-400
Auto-reversing response time: the bigger it is, the
lower the sensitivity is; the smaller it is, the higher
the sensitivity. Unit: millisecond.
4.3.10. Restore factory defaults: press the setting button to invert the color of the +-
symbol on the screen, and press ▲ and ▼ at the same time to restore the default
values of all parameters.
-------------------------------------------------------------------------------------------------------
4.4. "Advanced Menu" Command List of Master Motor
"Advanced Menu" access method: simultaneously long press the " 三" and "■"
button for 2 seconds to enter the menu setting status.
Advanced menu is for professional technician, general users should use it with
caution!
4.4.1. Auto-aging test
Sub-menu
Defaults
Range
Remarks
1.1 Time Interval
OFF
0-5, 0 is
OFF
Time interval for auto aging test; unit:
second.
1.2 Boom up
angle
0
0-90
Boom up angle after switching from off to
on. If the value is odd, it will keep
switching from off to on all the time, if the

13
value is even, it will turn from off to on
once and then completely turn off once
again, and repeat continuously.
4.4.2. Auto-open when power off
Sub-menu
Defaults
Range
Remarks
2.1 Low voltage
actuation time
OFF
0-5000,
0 is OFF
The time when the voltage is lower than
the set threshold and continues to exceed
the threshold, it will turn on automatically.
Unit: millisecond.
2.2 Low voltage
threshold
21
15-23
The operating voltage is lower than the
threshold; unit: V.
Notice:This function needs to be equipped with a backup power module.
4.4.3. Motor setting
Sub-menu
Defaults
Range
Remarks
3.1 Power value
when closing
0%
0-12%
When the spring force is not
enough and the boom may sag
down when the barrier gate closes
at down limit position, users can
increase this value appropriately to
get some force.
3.2 Motor type
129
Rotates
Forward
129 Forward/
Reverse
-CB03
Forward/
Reverse
It is used for matching the motor
type. This model must be set as 129
rotates forward for left-installation,
129 rotates reverse for
right-installation.
4.4.4. Relay output mode
The control board has two limit output relays. Users can set different output modes to
meet different application requirements.
Limit output: when the barrier gate opens to up limit position, the open relay will
close; when the barrier gate closes to down limit position, the down limit replay will
close; during the barrier gate opening or closing or stopping, these two relays are
disconnected. This function can be used with the system to monitor the status of the
barrier gate.
Alarm for boom swinging away: in this mode, "infrared signal input" and "GND"

14
interface are used as the signal interface of boom installation. If they are
short-circuited, it means that the boom works normally; if disconnected, it means that
the boom swings away. When the boom swings away, the barrier gate will open to up
limit position automatically and after then the up limit replay will stay in closing
status. When the boom is installed correctly and work normally (the signals are
short-circuited) again, the up limit replay will work normally.
Notice: This function needs to be equipped with inductive switch for detecting the
status of the boom.
Alarm against artificial lifting boom: in this mode, the up limit relay is used as an
alarm signal output. When the barrier gate closes at down limit position, if the boom
is artificially lifted up to a certain angle, the up limit relay will be closed for 15
seconds as an alarm output. An external alarm can be connected for alarm.
Down Limit Pulse Signal :After the boom runs to down limit position, the down
limit relay will send closing signal for a second. This function can be used as the
opening signal for the other barrier gate or other control system. The up limit replay
was closed when boom falls down, the signal during boom falling down and boom at
down limit position can be used as R&G light signal, or used for detecting the barrier
gate running status.
4.4.5. Buffer time for boom from closing to opening
Pressing open button in the process of closing, this parameter is used to set the buffer
time of the controller from receiving the command to starting to open.
4.4.6. Buffer time of barrier gate stopping
Pressing stop button in the process of barrier gate opening or closing, in order to
make the barrier stop smoothly, set a buffer time. This time is the time from the
barrier gate receiving the stop command to stopping completely.
4.4.7. Open the barrier gate by remote control to enter the motorcade mode
Open the barrier gate by remote control to enter motorcade mode directly. At this
time, the loop detector is invalid until closing the barrier gate. Closing barrier gate
both by wire control and by remote control can exit the motorcade mode. Opening the
barrier gate by wire control does not enter the motorcade mode. The default is "OFF".
Tip: When it is set to "OFF" in the up limit position, long press the "UP" button of the
remote controller for 4 seconds can also enter the motorcade mode; or pressing
"STOP" button on the controller with the program version of "10824" or above at the
up limit position can also enter this mode.

15
4.4.8. Valid time of loop detector signal
In the process of opening or up limit position, the duration time of the loop detector
signal needs to exceed the setting time, and the auto-closing action will be executed
after the loop detector signal disappears, avoiding that the loop detector signal is too
short and triggers the auto-closing action to hit the vehicles. The default time is
200ms. Range: 100ms-900ms.
4.4.9. Beep of Loop detector signal
There is loop detector signal (there is vehicle on the loop wire) when boom is at up
limit position, the buzzer will emit a hint tone. "ON" has a sound, and "OFF" has no
sound. “ON” is default.
4.4.10. Failure angle of loop detector anti-smashing
During the closing process, when the boom arrives at the setting angle from the
horizontal level, it will not respond to the signal of loop detector, to prevent vehicle
from being followed by other vehicles, and can also prevent the misoperation of the
loop detector from triggering the opening of the barrier gate. The default value is 5
degrees.
4.4.11. Failure angle on obstacle
During the closing process, when the boom arrives at the setting angle from the
horizontal level, if the boom meets on obstacle, it will not respond to barrier gate
opening. The default value is 10 degrees.
4.4.12. Switching angle of R&G light
When the boom opens to the setting angle, the relay of R&G light will close. The
default value is 60 degrees.
4.4.13. Wire control signal type measurement
"Infrared photocell", "loop detector/radar” and "stop" signals of the wire control
interface can be set to normal open input and normal close input, and the default is
normal open input.
4.5. Controller Parameter Setting of Slave Motor
Long press “ ” button for 2 seconds to enter the regular menu setting status. The
LED digital tube will display “F-XX”. Select menu items by short press or long press

16
"▲/+" and "▼/-" buttons, short press once to increase or decrease by one, long press
to continuously increase or decrease. When the required diameter displayed by the
LED digital tube, press “ ” button again to enter the setting of the specified item,
and press the "■/QUIT" to return to the previous level or exit the setting. When the
specified parameter setting is completed, you must press " " button to confirm it
to take effect. The currently set parameters is invalid if pressing "■/QUIT" button.
4.6. "Regular Menu" Command List of Slave Motor
Menu
Function
Defaults
Range
Recommended
Values
Remark
F-00
Boom Up
Speed
100
15-100
90-100
The larger the value, the faster the
boom up speed
F-01
Boom Down
Speed
100
15-100
90-100
The smaller the value, the faster the
boom down speed
F-02
Boom Up
deceleration
position
40
10-80
35-45
The angle at which the boom up
starts to decelerate, unit: degree
F-03
Boom Down
deceleration
position
45
10-80
40-55
The angle at which the boom down
starts to decelerate, unit: degree
F-04
Low-speed
working
angle of boom
up
90
15-90
90
The angle of the last section of
low-speed zone during boom up
F-05
Low-speed
working
angle of boom
down
0
0-75
0
The angle of the last section of
low-speed zone during boom down
F-06
Boom up limit
position speed
5
1-50
4-8
Boom up limit position speed
F-07
Boom down
limit position
speed
2
1-50
2-6
Boom down limit position speed
F-08
Position
adjustment of
horizontally
140
1-600+
130-140
Adjustment horizontal position of the
barrier gate

17
closing to limit
F-09
Swing range
adjustment of
horizontally
opening to limit
40
1-600+
40-50
Adjustment the vertical position of
the barrier gate
F-10
Delay
auto-close time
1
0-255
1
Auto drop off time when no car
passes, unit: second
F-11
Locking time of
opening to up
limit
5
0-255
5
Lock the gate for a period of time
after opening in place, unit: second
F-12
Locking time of
closing to down
limit
0
0-255
5
Lock the gate for a period of time
after closing in place, unit: second
F-13
Power-on
self-learning
speed
15
10-80
12-20
Find up and down limit at this speed
F-14
Remote control
learning
0
0-30
Learning remote control
F-15
Sensitivity of
Auto-reversing
on obstruction
5
1-40
3-10
Obstruction response time, unit: 0.05
second
4.7. "Regular Menu" Command Explanation:
F-02 Boom up deceleration position
It is used to set the starting position of deceleration in the process of boom lifting up.
The unit of angle is 0 degrees when the barrier gate is in the horizontal position and
90 degrees when it is in the vertical position. This parameter indicates that the barrier
will start to decelerate when the boom lifts up to this angle. If the boom shakes when
lifting to up limit position, this parameter can be reduced.
F-03 Boom down deceleration position
It is used to set the starting position of deceleration in the process of boom falling
down. The unit of angle is 0 degrees when the barrier gate is in the horizontal
position and 90 degrees when it is in the vertical position. This parameter indicates
that the barrier gate will start to decelerate when the boom falls down to this angle. If
the boom shakes when falling to down limit position, this parameter can be increased.
F-04 Low-speed running angle of boom up
This manual suits for next models
1
Table of contents
Popular Control System manuals by other brands

HEIDENHAIN
HEIDENHAIN LIF 181 R Mounting instructions

SEFRAM
SEFRAM Sequencer COMPACT manual

Commodore
Commodore VIC-RELAY-CASSETTE user manual

Siemens
Siemens SINUMERIK 828D PPU Series manual

Gamma Vacuum
Gamma Vacuum DIGITEL MPCe user manual

Linear Access
Linear Access AM/II Installation and programming instructions