Product features
•Inverter, UPS, AVR and charger function;
•Toroidal transformer design, high efficiency low static loss, much more energy-saving than
old square transformer type design;
•32-bit high speed CPU controlled, swift response speed, more accurate detection;
•LED colorful humanistic and friendly operation interface, displays clearly device's
working status, input & output voltage, loading status, battery status, etc.
•Pure sine wave output, suitable for almost all of appliance;
•High charging current
•Short switchover time, guarantees the connected appliances uninterruptable usage;
•Ventilation fan intelligent controlled, fan working based on the setting temperature and
working status.
Safety precautions
•This series product is designed for computer & internet devices and home appliance usage
not recommended in life support system and other special important equipment application.
•Avoid overloading, do not use the device beyond its maximum power capacity.
•It will be a danger of high voltage in the device even all the switches are turned off, any
operation to move or open the device should be performed by authorized professional
personnel.
•In case of fire, use dry powder type fire extinguisher, do not use liquid type fire
extinguisher.
•If the device works unusually, please switch off both power sources of battery and city
power immediately, any power source exist in such case will cause danger; and please
report to the distributor for professional advices.
Display, control and warning details
•Normal working interface
•Detail display

City power input normal, device through AVR supplies output
City power input abnormal, battery through inverter supplies AC output
Temperature is too high, device cuts off output
Battery over voltage, short circuit, high MOSFET’s temperature
City power input is over voltage
City power input is low voltage
Loading exceeds device’s rated power
Loading bar showing the loading situation
Battery bar showing the battery capacity, when in charging, the bar will be flashing
Input voltage indication
Output voltage indication and frequency indication
Operational description
Name
Component drawing
Description
Output switch
Pushing it for more than 2 seconds, switch on/off the
inverter or output
AC input cord or terminal
Plug it or connect it to wall socket or city power when
charges battery or supplies output through AVR
Main switch
When connect to city power and city power is normal, turn
on this switch, device will work on mains mode, charging
the battery;
Turn off this switch, device will switch over to battery
mode
Output socket or terminal
Appliance connect to this socket or terminal for output
Note: The Max. power for single socket is 2000W
If your appliance’s power is more than 2000W, please
connect to terminal
Ventilation fan
Under battery mode or charging, when the power transistor
temperature is higher than 45˚C, fan will start.
Battery input pole
Red battery input cable for positive pole, black battery
input cable for negative pole.
Be attention to the battery voltage must follow the device
marking.

Buzzer working status description
Working status
Description
When city power abnormal switch over to battery mode
Beeping on tine
Battery working low voltage or output overload
Beeping every second
Protection or output abnormal
Beeping hurry
Installation and operation
1. Installation:
1.1 If found any damage upon package opening, please contact distributor immediately;
1.2 Do not install the device up-side-down; not exposed to direct sunlight or heat source; out of
reach from children; away from water, moisture, oil or grease and any flammable substance;
1.3 For better ventilation, fan outlet and device ventilation hole should have at least 10cm
distance from the wall or other adjacent not heat producing equipment;
1.4 Make sure the city power voltage and frequency matches the device rated;
1.5 The device should be placed in the well grounded condition to ensure the safety;
2. Battery connection:
Connect the red cable to battery “+” pole and connect the black cable to battery “- ” pole, device
cannot work under wrong connection.
Technical parameter table
Power
500VA
800VA
1000VA
1500VA
2000VA
3000VA
5000VA
Battery voltage
12V DC
12V DC
12V DC
24V DC
24V DC
48V DC
48V DC
Charging current
Max. 5A-10A for model 500VA; 10-15 for model 800VA
Charging voltage
13.8V ± 0.5V
27.6V ± 0.5V
55V ± 1V
55V ± 1V
AC input range
On battery mode or power off, it returns to mains mode when input voltage is 165V±5V
~ 260±5V
On mains mode, it switch over to battery mode when input voltage is less than 150V±5V
or over than 270V±5V.
AC input frequency
45 Hz ~ 65Hz
Output range
Mains: 204V – 240V Inverter: 230V ±3%
Inverter output
frequency
50Hz/60Hz±0.5Hz, subject to the mains
Output overload
protection
Battery mode: when overload 110% ~ 130%, last 30 seconds before cut off the output;
when overload 130% and above, cut off the output immediately
Mains mode: warning till circuit breaker protects
Working ambient
temperature
0 ~ 40˚C
Working ambient
humidity
10% RH ~ 90% RH

Waste electrical and electronic equipment are a special waste category, collection,
storage, transport, treatment and recycling are important because they can avoid
environmental pollution and are harmful to health. Submitting waste electrical and
electronic equipment to special collection centers makes the waste to be recycled
properly and protecting the environment. Do not forget! Each electric appliance that
arrives at the landfill, the field, pollutes the environment!
Importer & distributor:
SC VITACOM ELECTRONICS SRL
CIF: RO 214527
Tel. 0264-438401*
This manual suits for next models
3
Table of contents
Other Well Inverter manuals