Wenglor LBA Series User manual

INTRODUCTION
RISK CLASS
This Technical User Guide contains warnings and guidance for correct and safe operation of the product.
These instructions must be followed at all times. wenglorTPL will not be held responsible for problems caused
by using the product contrary to these instructions and the Warranty will be deemed invalid.
UNPACKING
This product is packed at the factory using suitable materials for safe transport. To open thepackage, do not use
any cutting blade to avoid damaging the product(s). Please use the delivered accessories ifneeded. (Donot use any
other products or equivalents to replace the delivered accessories).
In the event of damage occurring during shipping, it must be reported to the carrier at time of delivery (including
noting the damage in writing on the delivery documents). It is also your responsibility to notify wenglorTPL in wri-
ting of the damage within 24 hours of receipt of the package. If these instructions are not followed, wenglorTPL
reserves theright not to accept requests for return and exchange of damaged products.
The applicable Standard EN-62471 classies LED Lighting into 4 classes according to their degree of hazard severity.
The table below summarises the risks associated with our standard products.
Color Class Risk
White WHI, Red 630 nm 0none
IR 850 nm 1low
LBAxxxx
OPERATING INSTRUCTIONS
wenglorTPL can provide guidance notes to minimise photo-biological risks, including the nominal minimum
operating distance. Please contact wenglorTPL through your usual representative for this information.
BEWARE to the infrared light, invisible to the eyes.
To know if the light is on, please refer to the LED indicators.
In all cases, wenglorTPL recommends
the use of protection glasses.

DIMENSIONS
P2/8
FIXING
Please use all the captive nuts. NEVER REMOVE THEM FROM THE BAR.
Additionally, there is the mounting accessory ZBAZ001, which can connect the bar light to surfaces and give 180°
secure rotational adjustments.
Captive nuts Screw M4
(supplied) (not supplied)
During the set up, the light has to be switched off and unplugged. Please
use M4 screws and insert them in thecaptive nuts located in the back of
the light. The light will be better fixed if you spread the attachment points
symmetrically along the bar.
You can also use M4 screws (not
supplied) fastened directly into
Aluminium profile with a tightening
torque from 0.5 to 1.5Nm. Wealso
recommend the use of a thread-
locker (not supplied) to avoid any
risk of loosening.
LBAxxxx
OPERATING INSTRUCTIONS
Total
length*
(mm)
Height
(mm)
Width
(mm)
Illumination
length
(mm)
A B C D
LBAx101 158 45 47.6 125
LBAx201 283 45 47.6 250
LBAx301 408 45 47.6 375
LBAx501 533 45 47.6 500
* Total length, without connector.
LBAx101 LBAx201 LBAx301 LBAx501
2captive
nuts
2captive
nuts
2captive
nuts
4captive
nuts
For additional sizes and colors, please speak to your
responsible sales representative.

LED INDICATORS
: Strobe LED indicator
: Power LED indicator
CONNECTION
WIRING
M12 Connector
5 male points
+ 24 V
1
2
3
4
Ground
PNP
5Dim 0-10V
STROBE PNP
:
+ 24 V
NPN
1
2
3
4
Ground
STROBE NPN
:
+ 24 V
1
2
3
4
Ground
PNP
+ 24 V
NPN
1
2
3
4
Ground
CONTINUOUS MODE :
or
2
4
1
+ 24 V
3GND
5DIM 0-10V
STROBE
NPN
STROBE
PNP 5Dim 0-10V
5Dim 0-10V 5Dim 0-10V
black
brown
blue
grey
white
Front view Top view
P3/8

LBAxxxx
OPERATING INSTRUCTIONS P4/8
VOLTAGE DROP
Dimensions LBAx101 LBAx201 LBAx301 LBAx501
Max voltage drop in the bar (V) 0.01 0.03 0.06 0.12
Power supply cable : 4x1,5² max length
for acceptable voltage drop (m)* >150
* For longer power supply cable, increase the section of the copper wire.
CONTROL
STROBE PNP & NPN
PNP : from 5 to 24V for 100% ON. From 0 to 1V for 100% OFF.
NPN : less than 1V for 100% ON. Above 2V for 100% OFF. Max 20V.
Brightness D max t max f max
100% N/A CW N/A
100% to 240% 1/5 30 ms 30Hz
D : Duty Cycle
t : pulse duration
f : frequency
OPERATING CONDITIONS
-10° to +40°C (14° to +104°F) / 80% of humidity without condensation.
No thermal shock (max temperature variation: 10°C (18°F) in 24h).
Not for outdoor use.
The product is optimised for a lifespan >50kh in a 40°C (104°F) atmosphere.
In strobe mode, the strobing time is directly equivalent to the time during which the strobe entry is activated.

P5/8
CONTINUOUS OPERATION STROBE OPERATION
DIMMING 0-10V – STROBE OPERATION
100%
240%
0 2 4 6 8 10
VOLTS
Potential dimming between
0 & 10 V.
At 0 Volts, the product reaches
240% of its lighting power. Only
usable in the Strobe mode.
Please consider a tolerance of ±5%
when measuring the dimmed bri-
ghtness levels.
STROBE
INPUT
STROBE
INPUT
STROBE
INPUT
30 ms 30 ms
< 30 ms
15 µs 15 µs
LIGHT
Triggering input
>30 ms
240%
100%
< 30 ms
15 µs 15 µs
LIGHT
Triggering input
<30 ms
> 30 ms
> 30 ms
15 µs 15 µs
LIGHT
Triggering input
>30 ms
100%
LED are supplied with 240% maximum
current. After 30ms, LED are supplied
at 100% level. After 30ms, LED are supplied at 100% level.

LBAxxxx
OPERATING INSTRUCTIONS
*strobed with 20% duty cycle.
POWER SUPPLY
USER SAFETY
Do not modify or dismantle all or part of the product.
Respect the power supply voltages and the connection terminals.
Ensure power supply is switched off whilst connecting product and turn on only once product
is fully connected. Failure to do this may damage the product and invalidate the Warranty
Do not stare at the lighting source directly.
Follow advice below for installation to minimise operator exposure to the light source.
P6/8
LBAx101 LBAx201 LBAx301 LBAx501
Consumption CW mode 0.3A 0.6A 0.9A 1.2A
Consumption Strobe mode* 1.2A 2.4A 3.6A 4.8A
Min. functioning Voltage 20V in the light input
Normal functioning Voltage 24V in the light input (±10%)
Max. functioning Voltage 30V in the light input
Max. consumption Strobe signal 5mA
INSTALLATION GUIDANCE:
• Forbid or limit the direct access to the lighting source (exposure into the radiation axis).
• Establish a security perimeter to prevent the operators from approaching the lighting source beyond therecom-
mendations of the manufacturer.
• If the workstation permits it, introduce a lter that will stop the lighting radiation under a xed or adjustable
frame between the source and the operator. When these measures cannot be implemented, supply the opera-
tors with glasses (class 4) or with a dedicated protective mask, that will stop thelighting radiation.
It is the responsibility of the persons installing this product to ensure that all means possible (such as those stated
above) have been implemented to reduce exposure of the machine operators to the light emitted from this product.

EQUIPMENT MAINTENANCE
P7/8
CLEANING (when the product is switched off)
Please use a soft and dry cloth. Do not use any abrasive material.
Do not use any cleaning solvent or aggressive chemical product.
wenglorTPL recommends to use isopropyl alcohol.
PRODUCT LIFETIME
LED lifetime can typically be increased using strobe mode where possible. Strobing the light or turning the illu-
mination on and off (using PNP or NPN lines) allows less temperature build up at the LED junction. The junction
temperature of the LED is directly correlated with the lifetime of the LED chip. Maximum ambient air temperature
= maximum 40°C/104°F.
LEDs naturally lose some intensity over time because of heat. Using the dimming and setting a reference
brightness is a method for keeping the brightness level constant over a very long time, especially on
brightness critical applications. wenglorTPL products have been integrated in factories since 2006, many of which
are still in operation today. LED lifetime and heat management are at the forefront of our design considerations.

+49 (0)7542 5399 800 support@wenglor.com www.wenglor.com
wenglor Straße 3
88069 Tettnang
Germany
Features and presentations liable to changes without notice. Ref.WOI-010201-A1, 2022/03 edition.
This manual suits for next models
13
Table of contents
Other Wenglor Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

DARAY
DARAY BILITE OPERATING AND INSTALLATION Manual

Bresser
Bresser SG Series instruction manual

NBG Home
NBG Home SMRTLite DS18876 Use and care guide

Federal Signal Corporation
Federal Signal Corporation Reliant Installation maintenance and service manual

thomann
thomann STAIRVILLE DJ Lase Polar 200 user manual

Lightolier
Lightolier D03 specification