INSTALLING THE SINEWAVE INVERTER SYSTEM
WARNING: Electrical Shock Hazard
The unit ‘On/Off’ switch does not disconnect the DC
power from the battery. Use the DC Disconnect Switch or
disconnect the DC input cables connection to disconnect
the DC power from the battery before working on any
circuits connected to the unit. Failure to follow these
instructions can result in death or serious injury.
Sinewave inverter Installation:
• Choose an appropriate mounting location.
• For indoor use, the orientation of the unit can be mounted in any
direction except with the DC Input panel facing downwards.
• For RV installation, the unit has to be mounted at on horizontal surface.
• Drill the 4 mounting holes, position the mounting screws and place the
inverter in position and fasten the inverter to the mounting surface.
Sinewave inverter Chassis Grounding Connection:
DANGER: The sinewave inverter chassis to be grounded properly. Never
operate the sinewave inverter without proper grounding. Failure to do so
will result in death or serious injury.
• Connect the grounding cable’s ring terminal to the unit ground screw.
• Connect the other side of the cable to the common grounding point.
Sinewave inverter DC Input Connection:
CAUTION: Reverse the DC Input terminal will damage
the unit and cannot be repaired. Damage caused by re-
verse polarity connection is not covered by the warranty.
• Connect one end of the negative DC input cable to the sinewave inverter
DC negative terminal. Connect the other end of the negative DC input
cable to the battery negative terminal.
• Make sure the Disconnect Switch is in the OFF position.
• Connect one end of the positive DC input cable to the sinewave inverter
DC positive terminal. Connect the other end of the positive DC input
cable to one of the terminal of the Disconnect Switch.
• Connect a DC input cable between the other terminal of the Disconnect
Switch and one side of the terminal of the fuse holder.
• Connect a DC input cable between the other terminal of the fuse holder
and the battery positive terminal.
• Install the selected fuse to the fuse holder.
• Turn Disconnect Switch to ON position.
Remote Switch (Optional for 1000 & 2000W) Connection:
• Insert the Remote Switch to the RJ11 Remote Port located at the Front
AC panel of the sinewave inverter. Please note polarity.
Test the sinewave inverter connection:
• Turn unit on by pressing and holding the On/Off button on the main unit
for about a second until a beep sound occur. The ‘Status’ light turns on
indicating the WhisperPower sinewave inverter is ON. Check the digital
display show measured battery voltage and output power alternatively.
Both AC output and 5V USB are now available.
• Plug in a small AC load like a 40W table lamp or small appliance to the
AC socket to verify AC is available.
• The unit is successfully installed and functioning properly.
3. UNIT OPERATION
WARNING: RISK OF EQUIPMENT DAMAGE
• Do not connect an AC power source like utility power or
generator to the unit 230VAC outlets.
Turn ON and OFF the 230VAC and USB
• Press and hold the “Power/Select” button for 1 second until a
beep is sounded. Display will show the measured battery voltage and
output power alternatively. Status LED will turn green. Both 5V USB
and 230VAC are available.
• Press “Power/Select” button to turn unit off.
Remote ON /OFF (Optional for 1000 & 2000W)
• If optional remote is used, the Remote ON/OFF momentary switch is
connected in parallel with the “Power/Select” button on the unit. Same
procedure applies to ON and OFF the unit.
Understanding the Display & Status LED (Only for 1000 & 2000W) Display:
’12.5’ Display shows measured battery voltage
‘0.80’ Display shows total output AC power in kW (800W as shown)
‘E01’ Display shows error or warning code.
See troubleshooting section for details + tabel
Status LED:
Green: Unit operation is normal
Amber: Warning is detected. Unit will shutdown at any time.
Please check error code to troubleshoot the unit.
Red: Error is detected and unit has shutdown.
Please check error code to troubleshoot the unit.
Understanding the Error Code (Only for 1000 & 2000W)
AC Load on sinewave inverter
Although the sinewave inverter can provide high surge power up to two
times the rated output power, some appliances may still trigger on the
inverter protection system. A higher sinewave inverter is required for those
appliances.
Estimate Run time on Load
Following run time are estimates, based on usage of a 12V-120Ah battery
bank for reference. Actual run times may vary.
4. TROUBLESHOOTING
To troubleshoot the unit, please note the error code display on the main unit
and review the “Understanding the Error Codes” in section 3.
5. WARRANTY
Two Years Limited Warranty
The limited warranty program is the only one that applies to this unit, and
it sets forth all the responsibilities of WhisperPower. There is no other war-
ranty, other than those described herein. Any implied warranty of merchant-
ability or fitness for a particular purpose on this unit is limited in duration to
the duration of this warranty.
This unit is warranted, to the original purchaser only, to be free of defects in
materials and workmanship for two year from the date of purchase without
additional charge. The warranty does not extend to subsequent purchasers
or users. Manufacturer will not be responsible for any amount of damage
in excess of the retail purchase price of the unit under any circumstances.
Incidental and consequential damages are specically excluded from
coverage under this warranty. This unit is not intended for commercial use.
This warranty does not apply to damage to units from misuse or incorrect
installation/connection. Misuse includes wiring or connecting to improper
polarity power sources.
Limitations:
This warranty does not cover accessories, such as adapters and batteries,
damage or defects result from normal wear and tear (including chips,
scratches, abrasions, discoloration or fading due to usage or exposure to
sunlight), accidents, damage during shipping to our service facility, altera-
tions, unauthorized use or repair, neglect, misuse, abuse, failure to follow
instructions for care and maintenance, fire and flood.
6. SPECIFICATIONS
NOTE: Specifications are subject to change without notice.
7. CE MANUFACTURER DECLARATION
Product: WhisperPower WP-Sine ‘AC Power from the battery’
Whisperpower guarantees that the unit complies
with the relevant standards.
WhisperPower BV
Kelvinlaan 82, 9207 JB Drachten, The Netherlands
Tel: +31 (0) 512 571 550, Fax: +31 (0) 512 571 599
info@whisperpower.com, www.whisperpower.com
Load Consumption Estimate Run time
Cordless Phone 5W 180 hrs
Clock/Radio 8W 135 hrs
Table Lamp 40W/60W 27 hrs/ 18 hrs
Freezer (250 ltr.) 80W 15 hrs
20” LCD TV 100W 11.5 hrs
Refrigerator (500 ltr.) 120W 9 hrs
Sump Pump (1/2 hp) 350W 3 hrs
Microwave (mid-size) 1000W 49 min
Coffee Maker 1200W 37 min
Code
Condition Corrective Action
E01 Unit has sensed input under Recharge battery immediately
voltage and has shutdown and restart unit
E02 Unit has sensed input over Check battery voltage or if any external
voltage and has shutdown
charger is connected to the battery bank
E03 Unit output has sensed overload Check load connected to the output.
or short circuit and was shutdown Reduce load and restart the unit
E04 Unit has sensed internal temperature Turn unit off and wait for 15 minutes
was high and has shutdown before restarting. Check if any object
has blocked the air flow of the unit
E05 Unit has sensed input voltage is Recharge battery as unit will
low and warning occurs shutdown shortly
E06 Unit has sensed load connected is Reduce load
close to overload shutdown limit
E07 Unit has sensed internal Reduce load and check if any
temperature is high and is close ventilation of the unit is blocked
to thermal shutdown limit
20141215 WP-Sine 12V manual EN
Problem Symptom Solution
No output voltage. The unit is off Turn unit ON by following the instruction
And Status in Section 4 to turn unit ON
LED is off. No power to inverter Check fuse or the Disconnect switch
(if installed) is either blown or turned OFF
No Output. Status Check error code Verify the error condition
LED is in Amber on display and make correction
(Only for 1000 & 2000W)
262
323
161
175
175
87
Schuko version
175
87
UK version
352
416
216
230
230
112
230
112
Schuko version
UK version
WP-SINE
12/400
WP-SINE
12/1000
WP-SINE
12/2000
WP-SINE
12/1000 UK
WP-SINE
12/2000 UK
WP-SINE
24/2000
Article nr.
61120510 61121500 61122500 61121501 61122501 61142500
AC output
Power (Continuous) 400W 1000W 2000W 1000W 2000W 2000W
Power (Peak, 500 mSec) 800W 2000W 4000W 2000W 4000W 4000W
Output voltage 230V 230V* 230V 230V 230V 230V
Output frequency 50Hz 50Hz* 50Hz 50Hz 50Hz 50Hz
Total harmonic distortion (THD) <5% true sine wave
DC input
Nominal battery voltage 12V 24V
Operation range 10.5 .. 15.5V 21 .. 31VDC
Input current 40A 94A 187A 94A 187A 94A
No load consumption 0.4A typical 0.8A typical 1.6A typical 0.8A typical 1.6A typical <0,1A (with
load sense on)
DC output
5V USB - Phone Charge 750mA 2,1A
DiSpLAY
LED indicator No Yes Yes Yes Yes Yes
Digital display Input Voltage / Current, Output Power
proteCtionS
Input Undervoltage Warning 11.2V 11.2V 11.2V 11.2V 11.2V 22.4V
Input Undervoltage Shutdown 10.5V 10.5V 10.5V 10.5V 10.5V 21V
Input Undervoltage Recovery 11.8V 11.8V 11.8V 11.8V 11.8V 23.6V
Input Overvoltage Shutdown 15.5V 15.5V 15.5V 15.5V 15.5V 31V
Output Power Warning Yes Yes Yes Yes Yes Yes
Output Power Shutdown Yes Yes Yes Yes Yes Yes
Output Short Circuit Yes Yes Yes Yes Yes Yes
Temperature Warning Yes Yes Yes Yes Yes Yes
Temperature Shutdown Yes Yes Yes Yes Yes Yes
Conformity Directive EMC 2004/108/EC Low voltage directive 2006/95/EC
Operating temperature range -20 .. 55°C (derating above 40°C)
Relative humidity in operation 5 - 90% without condensation
Ventilation Forced cooling
Dimension (lxdxh)
175x220x82mm 175x323x87mm
230x416x112mm
175x323x87mm
230x416x112mm 230x416x112mm
Weight 1.7kg 2.9kg 5.5kg 2.9kg 5.5kg 5.2kg
Battery connection M6 studs M6 studs M8 studs M6 studs M8 studs M8 studs
Ground Lug Connection M6 studs M6 studs M6 studs M6 studs M6 studs M6 studs
AC output
1 x Schuko socket 1 x Schuko socket 2 x Schuko socket
1 x UK socket 2 x UK sockets
2 x Schuko socket
Warranty 2 years
Schuko version
220
175