StopSummerColdsBeforeThey Start.
In some homes, comfort comes with side effects, especially during warmer times of the
year. Many people find that when they use their air conditioning systems, allergies,
headaches and cold symptoms seem to worsen. Unfortunately, air conditioning coils are
dark and damp, offering the perfect environment for the growth of harmful bacteria, fungi
and molds. So in establishing a comfortable temperature, homeowners can unwittingly
create unhealthy air.
The White-Rodgers UV Light is a remarkably effective means of arresting this bacterial
growth. The unit emits a germicidal ultraviolet frequency that penetrates the cell walls of
detrimental microbes, permanently neutralizing any ill effects. And better health isn't the
sole benefit. When mold or similar microbes have been reduced, air conditioner efficiency
often improves, saving the homeowner on operating costs.
Our multi-purpose UV lights have been designed to give you complete market coverage
with only two models (single lamp and dual lamp) - lowering your inventory costs. Each
unit features a universal electronic power supply, making it compatible with 120-240 volt
applications. And our exclusive tilt-bracket design allows each unit to adapt to specific
application needs by angling the bulb placement when needed. Plus, both units also use
the same UV-C lamps.
Features
. High-Output, Long-Life UV-CLamps
. Multi-Voltage Electronic Ballast(I 20/240V)
. Straight and Angle-Mount Brackets
. Power Switch and External Fuse
. 5-YearWarranty (I -YearBulbWarranty)
.Meets ULSafety Standards
(See back fol detailed agency listings)
UVl O0
The UVl O0single lamp emits light at 253.7
nanometers, the optimum light frequency in
combating the bacteria that commonly infest air
conditioners. Placeddirectly above the unit's coils, the
UV1O0halts existing growth and prevents recurrence.
Sizing- Suitable for slabcoil applications of three tons
and 1200 CFMor less,or where space permits only a
single lamp.
UV200
In homes that place higher demands on air
conditioning units, the UV200 dual lamp offers double
the intensity - andtwice the power to neutralize air
pollutants. And because this unit features increased
area coverage, it's a smart choice for homes and
businessesthat employ larger cooling systems.
Sizing - Suitable for slab coil, A-coil and return-air
applications, or where space allows dual lamps.
ModelUVIO0 67/8"Lx 111/g"Wx 2 ]/]6"H 41/21bs. 120V/240V,50/60Hz,1PH,3 amp-250Vfuse 45°F- 150°F(outsideofduct)
ModelUV200 67/8"[ x i43i16"W x 2'/16"H 6 3/4Ibs. 120V/240V,50/60Hz, ]PH,3amp:250V fuse 45t F- 150t F(outside 0fduct)
EMERSON,,
Specifications subject to change without notice Tile Emelson logo is a trademall< and a seMce mall< of Emerson Electric Co.
Germicidal OVLight UVSeries
Lamp Replacement (Annually)
It isrecommended to replace lamps annually even if they appear to
be operating normally because UV-Cenergy production diminishes
overtime.
Lamp Disposal
Spent UV lamps can be disposed of at local recycling centers or can
be sent back to White-Rodgers using the samecontainers that the
replacement lamps came in. Sendto the following address:
White-Rodgers UV Lamp Reclamation
] I ] 2 Industrial Park Drive
RoyseCity, TX 75189
Lamp Placement
Replacement Parts Part No.
UV-CLamp
Electronic Ballast (UVP100)
Electronic Ballast (UVP200)
Power Cord (120V)
Power Cord (240V)
Power Cord Receptacle
CoverInterlock Switch
Lighted On!Off Switch
Fuseholder
Fuse
UVP-06207
UVP-06212
UVP-06213
UVP-212261-00
UVP-212107-00
UVP-212106-00
UVP-212108-00
UVP-750-0026-001
UVP-212225-00
UVP-750-0108-001
Lamp insertion depth (into duct)
143132"
70°
143132"
) 90°
ExclusiveTilt-Bracket Design 11o°
. Allows customer to place bulbs "up" in tight spaces
Allows the bulb to be placed "down" overthe coil to get abetter angle over the coil
Inreturn-air applications, tilting one bulb "up" and the other "down" enables more of the air stream to be covered
Installation
UV lights areinstalled within the HVACsystem. Select a mounting location that will allow enough clearancefor the lamp to be
installed and replaced easily.The light may be mounted vertically or horizontally within the HVACsystem. For 240V electrical
outlets, an optional power cord must be purchased. Any modification to the supplied power cord will void ULsafety listing and
White-Rodgers warranty.
Installation Package
. Germicidal ultraviolet light system
. UV lamp(s)
. Powercord
. Sheet metal screws
. Installation & operation manual
. UVwarning label forduct
Listings
FIFRA-File# 73316 (FederalInsecticide FungicideRodenticideAct)
ULSafety Agency- File# E213952
White
Rodgers St. Louis, Missouri Markham, Ontario
314-553-3600 905-201-4701
www.white- rodgers.co m The EmersonIo9ois a #odemark and
aservicemark ofEmerson Elec#icCu. C __ate WR-9135-I

This manual suits for next models

3

Other White Rodgers Lighting Equipment manuals

White Rodgers Comfort Plus UV200 User manual

White Rodgers

White Rodgers Comfort Plus UV200 User manual

White Rodgers Comfort plus UV100 User manual

White Rodgers

White Rodgers Comfort plus UV100 User manual

Popular Lighting Equipment manuals by other brands

Ortech DISC-RG2 instruction manual

Ortech

Ortech DISC-RG2 instruction manual

ADJ MONSTER FUN User instructions

ADJ

ADJ MONSTER FUN User instructions

EuroLite LED IP Pad Series user manual

EuroLite

EuroLite LED IP Pad Series user manual

Ikan MYLO MB-2H1Q quick start guide

Ikan

Ikan MYLO MB-2H1Q quick start guide

AUTLED LC-007-034 user manual

AUTLED

AUTLED LC-007-034 user manual

Anslut 016916 operating instructions

Anslut

Anslut 016916 operating instructions

Viabizzuno clv 1 Installing instructions

Viabizzuno

Viabizzuno clv 1 Installing instructions

I-VALO DAVI EMERGENCY Operation and maintenance instruction

I-VALO

I-VALO DAVI EMERGENCY Operation and maintenance instruction

LIGMAN TANGO 30 installation manual

LIGMAN

LIGMAN TANGO 30 installation manual

Flash F7100250 manual

Flash

Flash F7100250 manual

Current GEPS24-180U installation guide

Current

Current GEPS24-180U installation guide

opto engineering LTBRZ3-C Series instruction manual

opto engineering

opto engineering LTBRZ3-C Series instruction manual

LIVARNO home 970-M manual

LIVARNO home

LIVARNO home 970-M manual

Rosco RoscoLED VariWhite Gaffer Kit user guide

Rosco

Rosco RoscoLED VariWhite Gaffer Kit user guide

CMP Brilliant wonders 25677 series installation instructions

CMP

CMP Brilliant wonders 25677 series installation instructions

Vision & Control LDLF30x480-B470/UDC Instructions for use

Vision & Control

Vision & Control LDLF30x480-B470/UDC Instructions for use

VELAMP WAINGRO manual

VELAMP

VELAMP WAINGRO manual

INFITRONIC IN18LEDKL user manual

INFITRONIC

INFITRONIC IN18LEDKL user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.