TECHNICAL SUPPORT
Telephone: 0161 331 5700
E-mail: technical@whitecrolight.com
hp://www.whitecrolighng.com/
Wiring Diagrams
DALI Models
Wire DALI for switch dim (using retracve switch)
Fixed Output
LIGHT ENGINE
Whitecro Lighng Limited
Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
Telephone +44 (0)870 5 087 087
Facsimile: +44 (0)870 5 084 210
Registered No. 3848973 England
Registered Oce: As above
Concert SL
Installaon Instrucons
OCTOBER 2016 - REV B 990.0302.01
Product Specicaon
IMPORTANT: The luminaire must not be covered by any debris or insulang material. Ensure there is a minimum of 50mm air-
space around the luminaire and control gear. Electrical terminaon must be carried out by a qualied electrician in accordance
with the latest edion of the IEE wiring regulaons BS7671.
PLEASE RETAIN THIS GUIDE FOR FUTURE REFERANCE AND RECYCLE PACKAGING.
Dimensions
Round Wallwasher Square Wallwasher
Square Downlight
Round Downlight
85 mm bezel
Ø79 mm cut-out
85 mm bezel
Ø79 mm cut-out
85x85 mm bezel
79x79 mm cut-out
85x85 mm bezel
79 x79 mm cut-out
Specicaon
Lamp Type:- LED
Supply:-220-240V, 50-60Hz
Power Output:- 8W & 14W
Nominal Lumen Output:- 500 lm to 1000 lm
Colour Temperature:- 3000K & 4000K
Ingress Protecon:- IP44
Trim Colour:- RAL9003 Signal White
50mm
50mm
Airspace around luminaire and driver
50mm
GENERAL INFORMATION
1)A qualied electrician, in accordance with IEE wiring regulaons should carry out connecon to mains wiring.
2) Ensure that the rated voltage and frequency requirements are compable with the available mains supply.
3) Cleaning of reectors and lenses should be carried out using clean, so and lint free cloths and an-stac cleaning uid.
4) Do not carry out high voltage insulaon test, i.e. 500/1000v this may damage internal components.
50mm
ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
Ceiling thickness:- MINIMUM 3mm*, MAXIMUM 30mm
*A PATTRESS IS RECOMMENDED FOR CEILING THICKNESS LESS THAN 3mm .
A
C
 Feed the driver and control gear into ceiling void,
ensuring it is not covered by debris or insulang
material and is correctly posioned.
D
E1
Reinstate mains
 Apply a bead of quick drying grip adhesive to the rear
face of the plaster in frame.
 Locate into hole.
 Secure frame into hole using plaster in screws (by others)
 Once adhesive has cured apply PVA bonding coat and
plaster up edge to frame.
 Apply nish to ceiling and allow to dry. Plaster and paint
must be dried completely before installing luminaire
into plaster in frame. Otherwise this may invalidate
warranty.
B2
E2
*IMPORTANT :- To avoid damage to so ceiling types care
must be taken when releasing the spring into the aperture.
 Squeeze ceiling springs and push the ng into the
ceiling void. It is important that the springs are held
from behind and only released once the luminaire is
in place. If there is a risk of the heatsink being covered
insert a yellow cap into the top of the luminaire.
 Once in place make sure the luminaire is secure in the
ceiling.
Yellow Cap
Yellow Cap
Remove reector and
pull down on
Luminaire
IMORTANT– Align dot on luminaire to dot on frame before
aempng to lock ng into place.
 Check the frame is clear of paint and plaster.
 Push the ng into the frame. If there is a risk of the
heatsink being covered insert the yellow cap into the
top of the luminaire.
To remove luminaire for maintenance:-
Twist out reector then pull down on luminaire
Specicaon
Lamp Type:- LED
Supply:-220-240V, 50-60Hz
Power Output:- 8W & 14W
Nominal Lumen Output:- 500 lm to 1000 lm
Colour Temperature:- 3000K & 4000K
Ingress Protecon:- IP44
Trim Colour:- RAL9003 Signal White
 Wire mains ex into driver according to the applicable
wiring diagram on the back of this leaet.
 Connect ex to mains supply.
Round—Cut a 79mm circular hole using a hole saw.
Square– Cut a 79mm square hole .
To avoid damage to the ceiling les it is not recommended to remove the luminaire once installed into so ceiling types . The luminaire
and driver can be maintained from the adjacent ceiling le or by removing the whole le with luminaire aached.
Push
IMPORTANT: When installing wall wash type
luminaires the plaster in frame must be installed with
the dot facing the wall to be illuminated.
 Remove Packaging
 Push down on Luminaire to remove from the
plaster in frame.
B1
PLASTER IN ONLY
PLASTER IN ONLY METAL PAN / SOFT CEILING
TYPES* / PLASTER BOARD

Other WHITECROFT LIGHTING Light Fixture manuals

WHITECROFT LIGHTING Concert EX2S User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Concert EX2S User manual

WHITECROFT LIGHTING Marine SD Manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Marine SD Manual

WHITECROFT LIGHTING MSU Surface User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING MSU Surface User manual

WHITECROFT LIGHTING Marine LF Manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Marine LF Manual

WHITECROFT LIGHTING FOIL single optic User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING FOIL single optic User manual

WHITECROFT LIGHTING Concert EX1S OR3 User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Concert EX1S OR3 User manual

WHITECROFT LIGHTING Duo 3 Evo User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Duo 3 Evo User manual

WHITECROFT LIGHTING Egress Exit Manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Egress Exit Manual

Popular Light Fixture manuals by other brands

Luxrite LR25140 Installation instruction

Luxrite

Luxrite LR25140 Installation instruction

IKEA IRSTA 204.069.47 manual

IKEA

IKEA IRSTA 204.069.47 manual

Larson Electronics HALP-48-2L-LED-DNMS instruction manual

Larson Electronics

Larson Electronics HALP-48-2L-LED-DNMS instruction manual

Inter-lux Sattler Sky Assembly instruction

Inter-lux

Inter-lux Sattler Sky Assembly instruction

Sagitter ARCHER B2 user manual

Sagitter

Sagitter ARCHER B2 user manual

Cooper Lighting CORELITE Indirect Wall Lighting Specifications

Cooper Lighting

Cooper Lighting CORELITE Indirect Wall Lighting Specifications

Westfalia Wetelux 91 96 03 Original instructions

Westfalia

Westfalia Wetelux 91 96 03 Original instructions

Philips CDB2SPF228 specification

Philips

Philips CDB2SPF228 specification

Viabizzuno c2 Installing instructions

Viabizzuno

Viabizzuno c2 Installing instructions

Philips 1050DRN specification

Philips

Philips 1050DRN specification

Schrack Technik ILAS LED Series Assembly instructions

Schrack Technik

Schrack Technik ILAS LED Series Assembly instructions

Lithonia Lighting SGLL 24 PIR installation instructions

Lithonia Lighting

Lithonia Lighting SGLL 24 PIR installation instructions

GLP Impression XL instruction manual

GLP

GLP Impression XL instruction manual

Chauvet Legend 412Z user manual

Chauvet

Chauvet Legend 412Z user manual

ALW LIGHTPLANE 11 installation instructions

ALW

ALW LIGHTPLANE 11 installation instructions

RSA Lighting ACCURUS TRIM ACT1985 Specification sheet

RSA Lighting

RSA Lighting ACCURUS TRIM ACT1985 Specification sheet

Cooper Lighting Quiet Ceiling Trimless QCT-1975 specification

Cooper Lighting

Cooper Lighting Quiet Ceiling Trimless QCT-1975 specification

Philips 33610-11-16 user manual

Philips

Philips 33610-11-16 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.