English SAFETY
2.3. Electrical work
ELECTRICAL hazard!
Incorrectly performed electrical work can
result in fatal injury! This work may only be
carried out by aqualied electrician.
BEWARE of moisture!
Moisture penetrating the cable will damage
both the pump and the cable. Never immerse
the cable end in uid and always protect it
from moisture. Unused wires must be insu-
lated!
Ourpumpsareoperatedwithalternating
orthree-phasecurrent.Thegoverningna-
tional directives, standards and regulations
(e.g.VDE0100)aswellastherequirementsofthe
local energy supply company must be observed.
Thepersonoperatingthepumpmustknow
where it is supplied with power and how to cut
offthesupply.Amotorprotectionswitchmust
be installed by the customer for three-phase AC
motors.Itisadvisabletoinstallaresidual-current
device(RCD).Ifthereisapossibilitythatpeople
can come into contact with the pump and the
uid(forexampleonconstructionsites),the
connection must be equipped with an additional
residual-current device (RCD).
Thesectionentitled“Electricalconnection”
must be observed when connecting the product.
Thetechnicalspecicationsmustbeobserved
strictly.Ourpumpsmustalwaysbegrounded.
If the pump has been switched off by aprotec-
tive device, it must not be switched on again
until the error has been corrected.
When the pump is connected to the electrical
control panel, particularly when electronic devices
such as soft start-up control or frequency con-
vertersareused,theswitchgearmanufacturer’s
specicationsmustbefollowedtocomplywith
the electromagnetic compatibility (EMC) re-
quirements. Special separate shielding measures
(e.g.shieldedcables,lters,etc.)maybeneces-
sary for the power supply and control cables.
Connections may only be made providing the
switchgears meet the harmonised EU standards.
Mobile radio equipment may cause malfunc-
tions in the system.
BEWARE of electromagnetic radiation!
Electromagnetic radiation can pose afatal
risk for people with cardiac stimulators. Put
up appropriate signs and make sure anyone
affected is aware of the danger!
2.4. Safety and monitoring devices
Thepumpsareequippedwithathermalwinding
monitor.Thepumpisswitchedoffifthemotor
gets too hot during operation.
Thisdevicemustbeconnectedbyanelectrician
and checked to ensure that it functions correctly
before commissioning.
Personnel must be informed about the built-in
systems and how they work.
CAUTION!
The pump should not be operated if the wind-
ing monitor has been removed, is damaged
and/or does not function!
2.5. Conduct during operation
When operating the pump, always follow the
locally applicable laws and regulations for work
safety, accident prevention and handling elec-
tricalmachinery.Tohelpensuresafeworking
practice, the responsibilities of employees should
beclearlyspeciedbytheoperator.Allpersonnel
are responsible for ensuring that regulations are
observed.
Due to their design, centrifugal pumps have
rotating parts that are easily accessible. Depend-
ing on the operating condition, sharp edges can
develop on these parts.
WARNING: Danger of crushing and amputation
of limbs!
Sharp edges can form on the rotating parts in
the hydraulics. These can result in crushing
and amputation of limbs.
• Never reach into the hydraulics when the
machine is in operation.
• Before performing maintenance or repairs,
switch off the pump, disconnect it from the
mains and secure it against being switched on
again without authorization.
• Always allow the rotating parts to come to
astandstill!
2.6. Fluids
Eachuiddiffersinrespectofcomposition,cor-
rosiveness, abrasiveness, dry matter content and
in many other aspects. Generally, our pumps can
be used for many applications. Please note that if
requirements change (density, viscosity or general
composition), this can also affect many parame-
ters of the pump.
Whenusingorreplacingthepumpinadifferent
uid,observethefollowingpoints:
• Theuidcanbecontaminatedbyoilfromthe
sealing chamber if the mechanical shaft seal is
defective.
Use with potable water is not permitted!
• Pumps that have been operated in dirty waste
water must be cleaned thoroughly before being
usedforotheruids.
• Pumps that have been operated in sewage water
containingfaecesand/oruidsthatarehazardous
to health must be decontaminated before being
usedwithotheruids.
Clarication must be sought as to whether the
pump can be used at all with another uid.