WilTec 61979 User manual

Operation Manual
Swimming Pool Reel System
61979
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ
insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

The information contained in this document is subject to change without prior notice. o part of this
document can be copied or duplicated in another form without the prior written consent of WilTec
Wildanger Technik GmbH. The WilTec Wildanger Technik GmbH assumes no liability for any errors in
this user manual or the connection diagram.
Although WilTec Wildanger Technik GmbH has made every effort to make sure that this user manual
is complete, accurate and updated, errors cannot always be avoided. In the event of problems with
this user manual please complete and send this form back to us.
FAX-notification +49 2403 55592-15),
from: ________________________________________
Name: ________________
Firm:_____________________
Tel/Fax:__________________
I would like to report the following mistakes:
_______________________________ ____________________________________
Customer Service WilTec Wildanger Technik GmbH
E-mail: [email protected]
Tel: +49 2403 55592-0
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury we urge that our
clients take some basic safety precautions when using this device. Please read the operation
instructions carefully and make sure you have understood its content.
Keep these operation instructions safe.
© by WilTec Wildanger Technik GmbH Seite 2
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

Reel seat (A+B)
Handle (C)
Crank handle (D)
Velcro top (E)
Velcro bottom (F)
Buckle (G)
Pool Cover (not included)
Clamps (H)
Base plate for pool side (J)
Clamp for pool edge (K)
Tapping screw (long) (L)
Tapping screw (short) (M/ U)
Screw and nut (N)
Cylinder screw (O)
Adapter for hexagonal tube (T)
Small hexagonal tube (P/ Q)
Big hexagonal tube (R)
© by WilTec Wildanger Technik GmbH Seite 3
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

Mounting
1)
Place D into A
Place C into B
2)
Place screw L into A and B
and tighten them.
Tip: Use a screwdriver with a magnetic
head. It will hold the screws in place whilst
D and A are being tightened.
The required length of the tube set is the length X, which describes the surface needing to be covered
between the reel seats. The surface reaches from the plug system of A to the plug system of B, after
placing the reel seats on each side of the pool.
To measure the length X for pools with an outer skirting, place both the base plates J on the skirting of
the pool (without attaching these permanently). Then position A and B on J and measure the distance
in between as previously mentioned.
© by WilTec Wildanger Technik GmbH Seite 4
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

For pools with a framework place K on the opposite sides of the frames, Place A and B on top of K
and secure one of the sides permanently. Then position the other side on top of K, to measure the
distance as previously mentioned.
4)
Note: The holes of the tubes P and Q should be facing towards the ends of both sides of the tube
system, so that the sides with the holes can be pushed onto the plug system of A and B.
5)
To connect the connections between R and P/ Q, fasten three screws of O into the pre-drilled holes of
R as shown. A minimum overlapping of 20 cm is required.
© by WilTec Wildanger Technik GmbH Seite 5
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

6)
Note: The pre-drilled holes on the tubes of P/ Q should be readily assembled and positioned onto the
plug system of the reel seats of A and B. Then push the tubes onto the plug system of the reel seats
of A and B.
Ensure that the two pre-drilled holes on the tubes of P/ Q and the hole on the axis are facing each
other parallelly. The tube then is connected via screw M to the axis of the plug system.
© by WilTec Wildanger Technik GmbH Seite 6
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

7)
For Above-Ground Pools with an Outer Skirting
Reel seats A and B are connected with a base plate J on the outer skirting boards. For wood and
plastic boards, connect one of the base plates J with the tapping screw L directly to the skirting board
with the screw and nut N. After measuring the distance, the tube needs to be placed on the axis of the
mounted side. After that the other side needs to be mounted as previously mentioned, after pushing
the tube onto the loose side.
If it is required to adjust the length of the tubes, loosen the 3 screws O of R. Then adjust the length
and fasten the screw O again.
© by WilTec Wildanger Technik GmbH Seite 7
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

8)
For Above-Ground Pools with a Framework
Position the reel seats A and B with clamp K on the framework of the pool and fasten
the screws adequately.
If it is required to adjust the length of the tubes, loosen the 3 screws O of R. Then adjust the length
and fasten the screw O again.
9)
Mount E, G and H as shown in the picture.
© by WilTec Wildanger Technik GmbH Seite 8
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

10)
Loosen the eight Velcro strips of F from E and remove the protective sheet. Stick them in straight lines
and with even gaps onto the tube (distance Y).
11)
For rectangular Infinity Pools
Open the cover over the pool and position it. Attach the clamps H on the cover and makes sure to
place them wit regular distances. Ensure that the length of the belts enable the cover to lay flat on top
of the pool, hindering any wind to get underneath the covering.
© by WilTec Wildanger Technik GmbH Seite 9
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de

12)
For round or oval Infinity Pools
Open the cover over the pool and clamp H to the cover with even gaps in between the Velcro on the
tube, as shown in the picture.
13)
Removal of the Reel System
To remove the reel system, push A and B out of the base plate J. Ensure that the reel seats are
positioned on the edge, to remove them..
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part of this instructions
manual require the written permission of WilTec Wildanger Technik GmbH.
© by WilTec Wildanger Technik GmbH Seite 10
http://www.WilTec.de
http://www.aoyue.eu March 2020 Version 40
http://www.teichtip.de
Other WilTec Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Flash professional
Flash professional P7110002 manual

LaserLight
LaserLight SPIDER LASER user manual

Vision & Control
Vision & Control LDLF60x600-W5K7/UDC Instructions for use

Prolux
Prolux MATRIX BAR 6 IP user manual

JB Systems
JB Systems TWINBEAM COLOR Mk2 Operation manual

Vision & Control
Vision & Control LDLF60x480-IR850/24V Instructions for use