Withings Body Pro User manual

REGULATORY INFORMATION
Withings Body Pro

Public
©2021 Withings

-3
Regulatory information
INTENDED USE
The Withings Body Pro is a connected scale intended to measure body weight and to
calculate the Body Mass Index (BMI). It is intended to be used in a home environment
by individuals 18 years of age or older.
IMPORTANT NOTICE
This product should not be used to diagnose or treat any medical condition.
WARRANTY
Your Body Pro scale is guaranteed to be free of material and workmanship defects for
a period of two (2) years from the date of receipt. This warranty does not apply to the
cellular data transmission that requires a data plan subscribed by the entity that has
provided you with this scale.
Withings hereby declares that the device Withings Body Pro is in conformity with the
essential requirements and other relevant requirements of Directive 2014/53/EU.
The declaration of conformity can be found at: withings.com/compliance
TECHNICAL INFORMATION
Measurement range (min-max):
11 lbs - 440 lbs
5 kg - 200 kg
1 st lb - 31 st lb
Resolution:
Precision: 100 g (3.5 oz)
Battery life: Approximately 12 months
Physical size: Length: 326.5 mm (12.9’’)
Width: 326.5 mm (12.9’’)
Depth: 23 mm (0.90’’) 33 mm (1.3‘‘)
Power source:
4x 1.5V AAA alkaline batteries (included)
Units: lb, kg, st lb
Working environment: Temperature: 5°C
to 35°C (41°F and 95°F)
Humidity: 30% RH to 80% RH
Atmospheric pressure: 80kPa to 105kPa
SYMBOLS DESCRIPTION
Complies with FCC regulations
Upper and lower limits of relative humidity
Upper and lower limits of pressure
Temperature range
RCM marking
Do not dispose of this product as unsorted
municipal waste; take it to electronic recycling
Follow instructions for use
2

Public
©2021 Withings
Regulatory information
CLASSIFICATION
Power by: Internally powered
Applied Part level: Type BF (Body Floating)
IP Protection level: IP22
Mode of operation: Continuous Operation
DISCONNECT DEVICE
Remove the battery to fully power off the device.
CAUTION
Potential allergic reaction may occur due to skin irritation.
Battery may be swallowed by children or pets and result in choking hazard, keep
replacement batteries away from them.
Keep away from children, pets, and pests after each use.
When in need of assistance, setting up, using, or maintaining or to report unexpected
operation or events please contact the manufacturer.
WARNING: No modification of this equipment allowed.
Activate the device at least once every three months to avoid battery leakage.
FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
SYMBOLS DESCRIPTION
Direct current
The CE logo certifies that the product complies with the essen-
tial requirements of Directive 2014/53/EU.
Scale button for unit change and menu access

-5
Regulatory information
IMPORTANT NOTE:
RADIATION EXPOSURE STATEMENT: This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. This equipment should
be installed and operated with minimum distance 20cm between the radiator and
your body. This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter. Country Code selection feature to be disabled for
products marketed to the US/CANADA. Contains FCC ID: 2AAGMGM02SA
INDUSTRY CANADA STATEMENT:
IC: 11411A-WBS09
This device contains licence-exempt transmitter(s)/receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference (2) This device must accept any interference,
including interference that may cause undesired operation of the device 2006/8/16 v1.0
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme
aux CNR d’Innovation, Sciences et Développement économique Canada applicables
aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes :
(1) L’appareil ne doit pas produire de brouillage;(2) L’appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Contains: IC: 12732A-GM02SA
Radiation Exposure Statement:
This equipment complies with Canada radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
Déclaration d’exposition aux radiations:
Cet équipement est conforme Canada limites d’exposition aux radiations dans un
environnement non contrôlé. Cet équipement doit être installé et utilisé à distance
minimum de 20cm entre le radiateur et votre corps.
Europe – EU Declaration of Conformity
This device complies with the essential requirements of the Radio Equipment directive:
2014 / 53 / EU.
The declaration od conformity can be found at: withings.com/compliance.
SW version: FW 201
The minimum distance between the user and/or any bystander and the radiating
structure of the transmitter is 20cm.
Transport/storage condition
Temperature: -10°C to 50°C (14°F to 122°F)
Humidity: 10% to 90%
Atmospheric pressure range: 80 kPa -105 kPa
4

Public
©2021 Withings
Regulatory information
DECLARATION - ELECTROMAGNETIC EMISSIONS AND IMMUNITY
For equipment and systems that are not life-supporting and are specified for use only in a shielded location
Guidance and manufacturer’s declaration-electromagnetic emissions
This cellular, Wi-Fi and Bluetooth scale is intended for use in the electromagnetic
environment specified below. The customer or the user of the cellular, Wi-Fi and Bluetooth
scale should ensure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment — guidance
CE emissions
CISPR11 Group 1
The cellular, Wi-Fi and Bluetooth scale uses RF
energy only for its internal function. Therefore,
its RF emissions are very low and are not likely
to cause any interference in nearby electronic
equipment.
RE emissions
CISPR11 Class B
Harmonic emissions
IEC 61000-3-2 Not applicable cellular, Wi-Fi and Bluetooth scale is suitable
for use in all establishments, including domestic
establishments and those directly connected to
the public low-voltage power supply network that
supplies buildings used for domestic purposes.
Voltage fluctuations/
Flicker emissions
IEC 61000-3-3
Not applicable
The cellular, Wi-Fi and Bluetooth scale declaration electromagnetic immunity
This cellular, Wi-Fi and Bluetooth scale is intended for use in the electromagnetic environment specified below. The customer or the user of
the cellular, Wi-Fi and Bluetooth scale should ensure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment – guidance
Conducted
RFIEC 61000-4-6
3 Vrms
150 kHz to 80 MHz
N/A N/A
Radiated RF IEC 61000-4-3 3 V/m
80 MHz to 2.5 GHz
N/A Portable and mobile RF communications equipment
should be used no closer to any part of the equipment
or system, including cables, than the recommended
separation distance calculated from the equation appli-
cable to the frequency of the transmitter. Interference
may occur in the vicinity of equipment marked with the
following symbol.
Declaration – electromagnetic immunity
The cellular, Wi-Fi and Bluetooth scale is intended for use in the electromagnetic environment specified below. The customer or the user of
the cellular, Wi-Fi and Bluetooth scale should ensure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment – guidance
Electrostatic discharge
(ESD)IEC 61000-4-2
Contact: ±8 kV
Air: ±2 kV, ±4 kV, ±8 kV,
±15 kV
Contact: ±8 kV
Air: ±2 kV, ±4 kV, ±8 kV,
±15 kV
Floors should be wood, concrete or ceramic tile. If
floors are covered with synthetic material, the relative
humidity should be at least 30%.
Electrical fast transient/ burst
IEC 61000-4-4
2 kV for power supply lines
1 kV for input/output lines
N/A The main power quality should be similar to that of a
typical commercial or hospital environment.
Surge IEC 61000-4-5 1 kV differential mode
2 kV common mode
line(s) to line(s): ±1kV
100 kHz repetition
frequency
The main power quality should be similar to that of a
typical commercial or hospital environment.

6-7
MODE FREQUENCY BAND
(MHz)
MAXIMUM OUTPUT
POWER (dBm)
BT EDR 2402 - 2480 0 dBm, 2.4G
BT LE 2412 - 2472 9 dBm, 2.4G
LTE 1710 - 1785 23 dBm
LTE 880 - 915 23 dBm
LTE 832 - 862 23 dBm
LTE 703 - 748 23 dBm
WLAN 2400 20 dBm
Voltage dips, short interrup-
tions and voltage variations
on power supply input lines
IEC 61000-4-11
-5% UT(95% dip in UT)
for 0.5 cycle, -40 % UT
(60% dip in UT) for 5 cycles,
-70% UT(30 % dip in UT) for
25 cycles, -5% UT
(95% dip in UT) for 5 sec
N/A The main power quality should be that of a typical
commercial or hospital environment. If the user of the
equipment or system requires continued operation
during power main interruptions, it is recommended
that the equipment or system be powered from an
uninterruptible power supply or a battery.
Power frequency (50/60 Hz)
magnetic field IEC 61000-4-8
30 A/m 50 Hz or 60 Hz 30 A/m 50 Hz and 60 Hz Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical com-
mercial or hospital environment.
NOTE: UT is the a.c. Main voltage prior to application of the test level
Regulatory information
Withings Website
www.withings.com

Withings Body Pro | V1.0 - Apr. 2021
© 2021 Withings. All rights reserved
2 rue Maurice Hartmann 92130 Issy-les-Moulineaux France
REG_WBS09_EN_003
Table of contents
Other Withings Measuring Instrument manuals

Withings
Withings Sleep Analyzer User manual

Withings
Withings Sleep Analyzer User manual

Withings
Withings Aura User manual

Withings
Withings Body Scan User manual

Withings
Withings Sleep Analyzer User manual

Withings
Withings Aura User manual

Withings
Withings Sleep Analyzer User manual

Withings
Withings Sleep Analyzer User manual
Popular Measuring Instrument manuals by other brands

Ashcroft
Ashcroft A Installation and maintenance instruction manual

WIKA
WIKA RVM/U-L-1 operating instructions

Castle group
Castle group dBAir operating manual

Agilent Technologies
Agilent Technologies N9039A Service guide

Acrel
Acrel AIM-R100 Installation and operation manual

Fieldpiece
Fieldpiece HG3 Field manual