3064816_201804 11
4. Specication
Type CGS-2-14/150R CGS-2-20/150R CGS-2-24/150R
Rated heating output at 80/60 °C kW 13.5 18.9/22.2 1) 23.8/27.1 1)
(23.8 3))
Rated heating output at 50/30 °C kW 15.2 20.4 25.8
Rated heat input kW 14.0 19.6/23.0 1) 24.6/28.0 1)
(24.6 3))
Lowest heating output (modulating) at 80/60 °C kW 1.8/4.6 2) 3.8/6.8 2) 4.8/6.8 2)
Lowest heating output (modulating) at 50/30 °C kW 2.1/5.4 2) 4.4/7.4 2) 5.6/7.4 2)
Lowest heat input (modulating) kW 1.9/4.9 2) 3.9/6.9 2) 4.9/6.9 2)
Heatingowconnection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20)
Heating return connection G ¾" (DN 20) ¾" (DN 20) ¾" (DN 20)
DHW connection G ¾" ¾" ¾"
Cold water connection/DHW circulation G ¾" ¾" ¾"
Gas connection R ½" ½" ½"
Balancedueconnection mm 60/100 60/100 60/100
Dimensions Depth mm 635 635 635
Width mm 600 600 600
Height mm 1792 1792 1792
Balancedue Type B23P, B33P, C13(x), C33(x), C43(x), C53(x),
C63(x), C83(x), C93(x)
Gas supply details
Natural gas E/H (Hi = 9.5 kWh/m³ = 34.2 MJ/m³) m³/h 1.44 2.06/2.42 2.52/2.95
Natural gas LL (Hi = 8.6 kWh/m³ = 31.0 MJ/m³) m³/h 1.59 2.28/2.67 2.79/3.25
LPG P (Hi= 12.8 kWh/m³ = 46.1 MJ/m³) kg/h 1.07 1.53/1.80 1.87/2.19
Standardseasonalefciency[toDIN]at40/30°C(Hi/Hs) % 110/99 110/99 110/99
Standardseasonalefciency[toDIN]at75/60°C(Hi/Hs) % 107/96 107/96 107/96
Efciencyatratedloadat80/60°C(Hi/Hs) % 98/88 98/88 98/88
Efciencyat30%partialloadandTR=30°C(Hi/Hs) % 109/98 109/98 109/98
Flow temperature, factory setting °C 75 75 75
Flow temperature up to approx. °C 90 90 90
Max. overall pressure, heating circuit bar 3 3 3
Residual head for heating circuit: HE pump (EEI <0.23)
600l/hpumprate(14kWat∆t=20K) mbar 550 550 550
860l/hpumprate(20kWat∆t=20K) mbar - 430 430
1030l/hpumprate(24kWat∆t=20K) mbar - - 280
Max. permissible overall pressure, DHW bar 10 10 10
DHW temperature range (adjustable) °C 15-65 15-65 15-65
Water content, heating water heat exchanger l 1.3 1.3 1.3
Nominal capacity of cylinder with internal indirect coil l 145 145 145
Spec.waterthroughput"D"atΔT=30K l/min 19.7 21.4 21.7
Continuous DHW output to DIN 4708 l/h (kW) 324 (13.6) 555 (22.6) 612 (25)
Output factor to DIN 4708 NL1.7 2.0 2.2
DHW output l/10 min 181 196 203
Standby heat loss to EN 12897 kWh/24 h 1.47 1.47 1.47
Corrosion protection, DHW heat exchanger/cylinder Two-layer enamel coating to DIN 4753
Expansion vessel, total capacity l 10 10 10
Expansion vessel, pre-charge pressure bar 0.75-0.95 0.75-0.95 0.75-0.95
Flue gas temperature 80/60-50/30 at Qmax °C 62-45 70-50 76-50
Flue gas temperature 80/60-50/30 at Qmin °C 30-25 30-25 33-27
FluemassowrateatQmax g/s 6.2 8.8/10.7 1) 10.9/13.0 1)
FluemassowrateatQmin g/s 0.9 1.8 2.3
Available gas fan draught at Qmax Pa 125 135 180
Available gas fan draught at Qmin Pa 10 14 17
Flue gas category G52 G52 G52
NOx class 6 6 6
Amount of condensate at 50/30 °C l/h approx. 1.4 approx. 2.0 approx. 2.4
pH value of condensate approx. 4.0 approx. 4.0 approx. 4.0
Power consumption on standby W 3 3 3
Maximum power consumption W 17-59/45 1) 17-51/63 1) 17-62/88 1)
IP rating IP IPX4D IPX4D IPX4D
Power supply/fuse protection 230 V/50 Hz/16 A/B
Total weight kg 115 (35+80) 115 (35+80) 115 (35+80)
CE designation CE-0085CO0098
ÖVG quality symbol [Austria] G 2,991
SVGW no. [Switzerland] 14-027-4
1) Heating mode/DHW mode
2) Natural gas/LPG (G31)
3) Applies only to Switzerland
Meets the requirements of proKlima and KfW.