manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wolf
  6. •
  7. Ventilation Hood
  8. •
  9. Wolf DD30I User manual

Wolf DD30I User manual

Other manuals for DD30I

4

This manual suits for next models

5

Other Wolf Ventilation Hood manuals

Wolf PI663418 Instructions for use

Wolf

Wolf PI663418 Instructions for use

Wolf PWC362418 Instructions for use

Wolf

Wolf PWC362418 Instructions for use

Wolf PW362418 Instructions for use

Wolf

Wolf PW362418 Instructions for use

Wolf L282212I User manual

Wolf

Wolf L282212I User manual

Wolf Drawer Microwave Oven User manual

Wolf

Wolf Drawer Microwave Oven User manual

Wolf W302718 Instructions for use

Wolf

Wolf W302718 Instructions for use

Wolf W422718 Instructions for use

Wolf

Wolf W422718 Instructions for use

Wolf CTWH36 User manual

Wolf

Wolf CTWH36 User manual

Wolf PW302718(R) Instructions for use

Wolf

Wolf PW302718(R) Instructions for use

Wolf W302210I User manual

Wolf

Wolf W302210I User manual

Wolf PI543418 User manual

Wolf

Wolf PI543418 User manual

Wolf PWC422418(R) Instructions for use

Wolf

Wolf PWC422418(R) Instructions for use

Wolf CTEIH42I User manual

Wolf

Wolf CTEIH42I User manual

Wolf DD36I Instructions for use

Wolf

Wolf DD36I Instructions for use

Wolf PL582212 User manual

Wolf

Wolf PL582212 User manual

Wolf PI363418 User manual

Wolf

Wolf PI363418 User manual

Wolf CTEWH30I Owner's manual

Wolf

Wolf CTEWH30I Owner's manual

Wolf CTEWH36 User manual

Wolf

Wolf CTEWH36 User manual

Wolf I423418 Instructions for use

Wolf

Wolf I423418 Instructions for use

Wolf L462212 Instructions for use

Wolf

Wolf L462212 Instructions for use

Wolf PW302718 User manual

Wolf

Wolf PW302718 User manual

Wolf W662718 Instructions for use

Wolf

Wolf W662718 Instructions for use

Wolf L402212 Instructions for use

Wolf

Wolf L402212 Instructions for use

Wolf e Series User manual

Wolf

Wolf e Series User manual

Popular Ventilation Hood manuals by other brands

Gorenje S3 IHGC963S4X manual

Gorenje

Gorenje S3 IHGC963S4X manual

KOBE ISX2136SQB-1 Installation instructions and operation manual

KOBE

KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products ADVANTAGE-100H Information & operating instructions

U.S. Products

U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg DUDL 4 LX Technical Passport

Kuppersberg

Kuppersberg DUDL 4 LX Technical Passport

Framtid HW280 manual

Framtid

Framtid HW280 manual

Thermador HGEW 36 FS installation manual

Thermador

Thermador HGEW 36 FS installation manual

Electrolux LFT769X user manual

Electrolux

Electrolux LFT769X user manual

AEG X69453MVO UK user manual

AEG

AEG X69453MVO UK user manual

Broan B5836SS manual

Broan

Broan B5836SS manual

Heinner HDCH-6060RGBK quick start guide

Heinner

Heinner HDCH-6060RGBK quick start guide

Baumatic AS35SS instruction manual

Baumatic

Baumatic AS35SS instruction manual

Franke FTF 604 XS V2 Instructions for use and installation

Franke

Franke FTF 604 XS V2 Instructions for use and installation

Best UCB3I30SBW installation instructions

Best

Best UCB3I30SBW installation instructions

Gram EFU 503-90 X instruction manual

Gram

Gram EFU 503-90 X instruction manual

CIARRA CBCS6803 Installation and user manual

CIARRA

CIARRA CBCS6803 Installation and user manual

sauter SHG501 Instructions for installation and use

sauter

sauter SHG501 Instructions for installation and use

Franke 392-17 User instructions

Franke

Franke 392-17 User instructions

FALMEC Polar Black 35 Instruction booklet

FALMEC

FALMEC Polar Black 35 Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION INSTRUCTIONS
DOWNDRAFT VENTILATION
As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Wolf equip-
ment. There are two types of potential
hazards that may occur during installation.
Another footnote we would like to identify is
IMPORTANT NOTE: This highlights informa-
tion that is especially relevant to a problem-
free installation.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
states a hazard that may cause serious
injury or death if precautions are not
followed.
WOLF®is a registered trademark of Wolf Appliance Company, Inc.
CONTACT
INFORMATION
Wolf Customer
Service:
800-332-9513
Website:
wolfappliance.com
3
INSTALLATION REQUIREMENTS
IMPORTANT NOTE:
This installation must be
completed by a qualified installer or Wolf
authorized service center technician.
Installer:
Please read the entire Installation
Instructions prior to installation. Save these
instructions for the local inspector’s refer-
ence, then leave them with the homeowner.
Homeowner:
Please read and keep these
instructions for future reference and be sure
to read the entire Use & Care Information
prior to use.
Any questions or problems about the
installation should be directed to your Wolf
dealer or Wolf Appliance Company, Inc. at
800-332-9513. You can also visit our website
at wolfappliance.com.
IMPORTANT NOTE:
This appliance must be
installed in accordance with National Electrical
Codes, as well as all state, municipal and local
codes. The correct voltage, frequency and
amperage must be supplied to the appliance
from a dedicated, grounded circuit which is
protected by a properly sized circuit breaker or
time delay fuse. The proper voltage, frequency,
and amperage ratings arelisted on the product
rating plate.
Recordthe model and serial numbers before
installing the downdraft ventilation system.
Both numbers are listed on the rating plate,
located above the airbox on the front side of
the unit. Refer to the illustration below.
BEFORE YOU START
Proper installation is the responsibility of
the installer. Product failure due to
improper installation is not covered under
the Wolf Warranty. Refer to the Downdraft
Ventilation Use & Care Information for
warranty details, or visit our website,
wolfappliance.com.
Check with local utilities for electrical codes
that apply in your area. Local codes vary.
Installation, electrical connections and
grounding must comply with applicable
codes. In the absence of local codes, this
appliance should be installed in accordance
with National Electrical Code ANSI/NFPA
70-1990 or latest edition.
This appliance must be properly grounded.
Refer to Electrical Requirements on
page 8.
Make sure you have the tools and materials
necessary for proper installation.
Any required service must be performed by
a Wolf authorized service center.Wolf is not
responsible for service required to correct a
faulty installation.
WOLF DOWNDRAFT VENTILATION SYSTEMS
RATING PLATE
INFORMATION
Model Number
Serial Number
Rating plate location
Location of
rating plate
OVERALL DIMENSIONS
MODELS DD30I AND DD30R
Overall Width 30" (762)
Width of Chimney 261/4" (667)
Overall Height
(above countertop)
91/16" (230)
Overall Depth 23/8"(60)
Depth of Chimney 11/2"(38)
MODELS DD36I AND DD36R
Overall Width 36" (914)
Width of Chimney 321/4" (819)
Overall Height
(above countertop)
91/16"(230)
Overall Depth 23/8"(60)
Depth of Chimney 11/2"(38)
MODELS DD45I AND DD45R
Overall Width 451/2" (1156)
Width of Chimney 411/4" (1048)
Overall Height
(above countertop)
91/16" (230)
Overall Depth 23/8"(60)
Depth of Chimney 11/2"(38)
4
WOLF DOWNDRAFT VENTILATION SYSTEMS
DOWNDRAFT VENTILATION
IMPORTANT NOTE:
Wolf downdraft ventila-
tion systems are recommended for use with
Wolf framed electric, gas, induction and
multi-function cooktops. They cannot be used
with unframed electric cooktops and are not
recommended for use with the electric grill,
steamer and fryer modules. A Pro ventilation
hood is recommended for use with Wolf dual
fuel ranges, gas ranges, sealed burner range-
tops and gas rangetops.
IMPORTANT NOTE:
Adowndraft can be
used with sealed burner rangetop Models
SRT304 and SRT366. An accessory trim kit
(SRT/DDTRIM) is necessary for this installation.
Contact your Wolf dealer for details.
Wolf downdraft ventilation systems are
available in 30" (762), 36" (914) and 451/2"
(1156) widths. The downdraft should be at
least as wide as the cooktop.
Models DD30I, DD36I and DD45I include a 500
CFM internal blower. Models DD30R, DD36R
and DD45R are shipped without a blower
assembly. Remote blowers are available as
sales accessories.
IMPORTANT NOTE:
The downdraft must be
used with a Wolf-approved control module and
top cover.
The illustrations below provide the overall
dimensions for downdraft Models DD30, DD36
and DD45.
Overall dimensions – Models DD30I and DD30R
23/8"
(60)
30"
(762)
91/16"
(230) 261/4"
(667)
11/2"(38)
DEPTH OF
DOWNDRAFT CHIMNEY
36"
(914)
321/4"
(819)
23/8"
(60)
91/16"
(230)
11/2"(38)
DEPTH OF
DOWNDRAFT CHIMNEY
Overall dimensions – Models DD36I and DD36R
Model DD30
Model DD36
Model DD45
Dimensions may vary to +
–1/8"(3).
BLOWER OPTIONS
Wolf downdraft Models DD30I, DD36I and
DD45I include a 500 CFM internal blower.
Models DD30R, DD36R and DD45R are shipped
without a blower assembly and can be used
with the remote blowers listed below. Remote
blowers are available as sales accessories.
Models DD30R, DD36R and DD45R
900 CFM Remote Blower
801641
1200 CFM Remote Blower
801642
1500 CFM Remote Blower
804701
IMPORTANT NOTE:
Blower options vary with
the cooking surface. For recommendations,
refer to the Wolf Design Guide found on the
Wolf website, wolfappliance.com.
IMPORTANT NOTE:
Install this downdraft
ventilation system only with a Wolf blower.
5
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
CONTROL KITS
IMPORTANT NOTE:
The downdraft must be
used with a Wolf-approved control module and
top cover.
The remote-mounted control module and top
cover are available in the classic, platinum and
carbon stainless steel finish for Models DD30
and DD36, and classic stainless steel only for
Model DD45.
The control kit, available as a sales accessory
for Models DD30 and DD36 and included with
Model DD45, includes the control module, top
cover, mounting brackets, RJ45 connector and
mounting hardware.
Models DD30I and DD30R
Classic Stainless
DD30CONTROL/S
Platinum Stainless
DD30CONTROL/P
Carbon Stainless
DD30CONTROL/B
Models DD36I and DD36R
Classic Stainless
DD36CONTROL/S
Platinum Stainless
DD36CONTROL/P
Carbon Stainless
DD36CONTROL/B
Optional downdraft accessories are available
through your Wolf dealer. To obtain local
dealer information, visit the Locator section of
our website, wolfappliance.com.
Overall dimensions – Models DD45I and DD45R
451/2"
(1156)
411/4"
(1048)
23/8"
(60)
91/16"
(230)
11/2"(38)
DEPTH OF
DOWNDRAFT CHIMNEY
INSTALLATION SPECIFICATIONS
Wolf downdraft Model DD30 will fit most 30"
(762) wide cabinets, Model DD36 will fit most
36" (914) wide cabinets and Model DD45 will fit
most 451/2"(1156) wide cabinets. It is recom-
mended that oversized cabinets be used for
easier installation. Cabinet backs may need to
be removed.
Wolf downdraft ventilation systems can be
mounted in an island, peninsula or standard
wall location.
The illustration below provides installation
dimensions for all Wolf downdraft models.
Pay careful attention to the areas of potential
interference as noted in the illustration.
IMPORTANT NOTE:
To install a downdraft
system and a Wolf cooktop, you must allow for
aminimum 251/8"(638) flat counter space from
front to back. A countertop with a raised lip or
backsplash may not allow enough space for
proper installation. 23/8"(60) of flat countertop
is required behind the cooktop and 13/4"(44) is
necessary between the back edge of the
cooktop and inside of cabinet back.
If downdraft Model DD30 is installed in
combination with with two cooktops or inte-
grated modules, an integrated module support
(ISUPPORT) for downdraft ventilation is
required. ISUPPORT is not required for Model
DD45. If optional filler strips are used with the
cooktops or modules, be aware that they are
different for the Model DD30 and DD45. Be
sureto use the correct filler strip.
6
WOLF DOWNDRAFT VENTILATION SYSTEMS
21/8"(54)
191/4"(489)
COOKTOP CUT-OUT
DEPTH
2
36"
(914)
23/8"(60)
251/8"min (638)
OF FLAT COUNTERTOP*
.344"
295/16"
(745)
COUNTERTOP
TO BOTTOM OF
AIR BOX
18"
(457)
35/8"
(92)
31/4"
(83)
5"
(127)
711/16"
(197)
5/8"
(16) 21/2"min
(64)
WITH NO
RAISED LIP*
*AREAS OF POTENTIAL INTERFERENCE
24"min (610)
CABINET DEPTH
13/4"min (44)
BACK EDGE
OF COOKTOP
TO INSIDE OF
CABINET BACK*
71/8"
(181)
2
Downdraft installation dimensions
7
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
For installation of a downdraft system with a
cooktop, refer to the cooktop installation
instructions for the dimensions of the cooktop,
countertop cut-out and cabinet requirements.
The depth of the cooktop may vary and will
affect the location of the downdraft in the
countertop.
The illustration below provides countertop
cut-out dimensions for downdraft Models
DD30, DD36 and DD45 installed with a Wolf 30"
(762) or 36" (914) cooktop or combination of
cooktop and/or modules.
IMPORTANT NOTE:
For installation of a
downdraft with sealed burner rangetop Models
SRT304 and SRT366, an accessory trim kit
(SRT/DDTRIM) is necessary. Contact your
Wolf dealer for details. To obtain local dealer
information, visit the Locator section of our
website, wolfappliance.com.
CONTROL MODULE LOCATION
Installation of the remote-mounted control
module can be located anywhere within 10'
(3 m) of the downdraft assembly and a
minimum of 4" (102) from the outer edge of
cooktop element or burner. You will be
required to drill three holes and connect the
control module to the downdraft assembly
using the cable provided.
The remote-mounted control module is
23/8"(60) x 65/8"(168) and can be positioned
horizontally or vertically in the countertop. A
1" (25) diameter hole for the RJ45 connector
cable will be centered horizontally and verti-
cally in the back side of the control module.
Two 1/4"(6) diameter holes for the mounting
screws will be located 2" (51) from the center
of the RJ45 connector cable hole,one on each
side. Additional installation instructions are
provided with the control kit.
Mark the center of the control module on the
counter top. Measure2" (51) up (or left) and 2"
(51) down (or right) to locate holes for the
mounting screws.
IMPORTANT NOTE:
The length of the control
module cable is 10' (3 m). You must plan the
installation of the control module to be within
10' (3 m) of the downdraft assembly.
27" (686)
FOR MODEL DD30
33" (838)
FOR MODEL DD36
42" (1067)
FOR MODEL DD45
21/2"min (64)
23/4"(70)
COOKTOP CUT-OUT
WIDTH
251/8"min
(638)
FLAT
COUNTERTOP
SPACE
191/4"
(489)
COUNTERTOP TOP VIEW
Countertop cut-out dimensions
IMPORTANT NOTE:
Aground fault circuit
interrupter (GFCI) is not recommended and
may cause interruption of operation.
You must follow all National Electrical Code
regulations. In addition, be aware of local
codes and ordinances when installing your
service.
8
WOLF DOWNDRAFT VENTILATION SYSTEMS
ELECTRICAL REQUIREMENTS
Wolf downdraft ventilation systems require a
separate, grounded 120 V, 60 Hz power supply.
The service should have its own 15 amp circuit
breaker, and a grounded 3-prong receptacle
should be located within the reach of the 21/2'
(.8 m) power cord. The specific location of the
outlet is not critical, as long as it is within
reach of the power cord that is located mid-
way, top and bottom, on the right side of the
downdraft.
IMPORTANT NOTE:
If Model DD30 is to be
installed in a 30" (762) wide cabinet, Model
DD36 in a 36" (914) wide cabinet or Model
DD45 in a 451/2"(1156) wide cabinet, the
electrical outlet cannot be located on the back
wall of the cabinet. The outlet can be placed in
an adjacent cabinet within reach of the power
cord. An access hole for the power cordmust
be drilled in the cabinet wall.
Choose the electrical location shown in
the illustration below that best suits your
installation.
Do not use an extension cord or two-
prong adapter. Electrical ground is
required on this appliance. Do not remove
the power supply cord ground prong.
The electrical outlet must be checked by
a qualified electrician to be sure that it is
wired with the correct polarity. Verify
that the outlet provides 120 V AC and is
properly grounded.
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
Location of electrical
36" min (914)
FOR MODEL DD36
451/2"min (1156)
FOR MODEL DD45
30" min (762)
FOR MODEL DD30
OPTIONAL
ELECTRICAL
LOCATION IN
ADJACENT RIGHT
SIDE CABINET
E E
31/2"(89)
4" min (102)
10" (254)
24" min (610)
CABINET DEPTH
9
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
ADJUSTABLE DISCHARGE
Wolf downdraft systems have an adjustable
discharge that will allow you to negotiate
ducting around floor joists and other obstacles.
Three different discharge locations are avail-
able with side-to-side adjustment for accurate
alignment of ductwork. Refer to the illustration
below for the discharge location and adjust-
ment that best suits your installation.
BLOWER CONSIDERATIONS
The blower will vary in size and is dictated by
the cooking surface, the volume of air that
needs to be moved and the length of the duct
run. A straight, short duct run with a limited
number of elbows and transitions will allow
the downdraft to perform most efficiently.
Aremote-mounted blower will minimize the
amount of blower noise, but will not eliminate
the noise completely.
IMPORTANT NOTE:
Blower options vary with
the cooking surface. For recommendations,
refer to the Wolf Design Guide found on the
Wolf website, wolfappliance.com.
DISCHARGE CUT-OUT
DIMENSIONS:
101/4"(260) x 31/2"(89)
INTERNAL BLOWER
141/4"(362) x 31/2"(89)
IN-LINE OR
REMOTE BLOWER
CENTERLINE OF COUNTERTOP CUT-OUT 163/8"(416)
INTERNAL BLOWER
211/2"(546)
IN-LINE OR
REMOTE BLOWER
51/2"(140)
INTERNAL BLOWER
41/4"(108)
IN-LINE OR
REMOTE BLOWER
CL
221/8"(562)
INTERNAL BLOWER
19" (483)
IN-LINE OR
REMOTE BLOWER
RIGHT
DISCHARGE
LOCATION
LEFT
DISCHARGE
LOCATION
CENTERLINE OF COUNTERTOP CUT-OUT
141/4"(362) x 31/2"(89)
IN-LINE OR
REMOTE BLOWER
CENTERLINE OF COUNTERTOP CUT-OUT
51/2"(140)
INTERNAL BLOWER
41/4"(108)
IN-LINE OR
REMOTE BLOWER
CL
NOTE: Measurements are to centerline of duct cut-outs
ADJUSTMENT:
5" MAX (127)
IN-LINE OR
REMOTE BLOWER
ADJUSTMENT:
1" (25) – 7" (178)
INTERNAL BLOWER
21/2"MAX (165)
IN-LINE OR
REMOTE BLOWER
BOTTOM
DISCHARGE
LOCATION
Downdraft adjustable discharge
10
WOLF DOWNDRAFT VENTILATION SYSTEMS
Choose the ducting option that allows the
shortest length of ductwork and a minimum
number of elbows and transitions. Check the
location of floor joists, wall studs, electrical
wiring or plumbing for possible interference
with the ductwork. Refer to the illustrations
below for ducting options.
IMPORTANT NOTE:
Use duct tape to seal the
connection between the blower outlet and
ductwork. Support the weight of the ductwork
as necessary to ensure sealed joints.
DUCTING CONSIDERATIONS
IMPORTANT NOTE:
Always consult a
qualified HVAC Engineer for specific ducting
applications.
IMPORTANT NOTE:
Wolf ventilation down-
draft systems must be vented to the outside.
Use only metal ductwork.
Wolf downdraft ventilation systems are
designed for use with 31/4"(83) x 10" (254)
ductwork for Models DD30I, DD36I and DD45I,
and 31/4"(83) x 14" (356) ductwork for Models
DD30R, DD36R and DD45R. Each can be
transitioned to 8" (203) or 10" (254) round
ductwork.
For best performance, 10" (254) round
ductwork is recommended. The downdraft will
operate most efficiently when the ductwork
does not exceed 40' (12 m) in length.
12" MIN
TO
GROUND
WALL CAP
INTERNAL BLOWER
INSTALLATION THROUGH WALL
R
Downdraft ducting options
12" MIN
TO
GROUND
INTERNAL BLOWER
INSTALLATION THROUGH WALL
1
12" MIN
TO
GROUND
10"
ROUND
REMOTE BLOWER
INSTALLATION THROUGH WALL
REMOTE
BLOWER
REMOTE BLOWER
ROOF MOUNT INSTALLATION
1
REMOTE
BLOWER
10"
ROUND