Product Space & Power Requirements
Item Xer x Nuvera™ 100/120 Digital
C pier/Printer
C mments
Size – Printer
w/ 1 SFM &
Pr fessi nal
MFF
131.3” W) x 30” D) x 61.6” H)
3336mm x 736mm x 1565.6mm
Width –
additi nal
SFM
31.7” 805mm)
Optional
Service Space Fixed: 162” W) x 113” D)
4114.8mm x 2870.0mm)
Moveable: 162” W) x 92” D)
4114.8mm x 2336.8mm)
- Fixed stationary) installation: rear of the
system should be at least 30” from the wall.
- Moveable installation: rear of the system
should be at least 10” from the wall and must
be on mobility plates OR hard surface floor
AND 4 modules or less.
Weight 1,753 lb. 795.1 kg)
Additional SFM – 423 lbs. 191.9 kg)
With consumables loaded except media)
P wer and
Agency
Requirements
N rth America
208 Volts / 30 Amp sole use, 60 Hz
Two phase, 3 wire + PE L1, L2, N, GND)
• UL & cUL compliant
• Complies with the FEMP Federal Energy
Management Program) via the machine
circuit breaker CB); with the CB switched
off, the system consumes less than 1 watt.
• Energy Star eStar) compliant
• Environmental Choice Canada)
•
omplies with Section 508 of the ADA
Rehabilitation Act
P wer
Requirements
Eur pe/Japan
200-240 Volts / 25 Amp sole use, 50 Hz
Single phase, 2 wire + PE L, N, GND)
• Energy Star eStar) compliant
• Units are compliant with applicable EU
directives and are CE marked
System Configuration and Installation
Installati n Preparati n D cument
This section should be used in conjunction with the Xerox Nuvera™ 100/120 Digital Copier/Printer
Installation Planning Guide (IPG) and the Xerox Nuvera™ 100/120 Digital Copier/Printer Installation
Preparation Do ument (IPD), which contain detailed specifications for size, weight, electric, and
environmental conditions. Only the most important requirements are stated here.
Customer Responsibilities
The following must be completed before the system can be delivered and will be assessed in the final site
check:
Item C mments
Identify placement f the system
Ensure the printer can be delivered t the site
Supply the appr priate electrical c nnecti ns Dedicated power required
Install an exhaust duct t vent h t air t the air
system r the utside if required
Heat Vent Kit is available for stationary system
installations only. The kit lowers the system’s output
from approximately 17,500 BTU/hour to 8,500 BTU/hr.
Verify the strength and sl pe f the fl r