Xintex G-1B-R Series Original instructions

xlilJEx.
Gasoline Fume Detection System
Single ChannelSvstems
G-LB-R (Black, Round;':
G-1C-R (Chrome, Round)
Dual Channel Svstem
G-2B-R (Black, Square)
Owner's Manual
&
lnstallation lnstructions
Read and comply with all instructions, warnings and limitations before
installing, servicing or removing this device.
1
Part Number 18140, D, OL/26/20L7
I-
\//
\---- \
a--:/

Additional copies of this manual are available at no charge by contacting the manufacturer,
distributor or dealer. Fireboy-Xintex reserves the right to change features without notice.
General lnformation
Specifications
Operation of Xintex Gasoline Fume Detector(s)
lnstallation
lnstalling the Display Unit (GLBR-No1-D/G1CR-N01-D or G2BS-N01-D)
Routing Sensor Cable(s) (FS-X01 CABLE XX')
lnstalling Gasoline Fume Sensor(s) (FST01)
Electrical Connections (G1BR-N01-D/G1CR-N01-D or G2BS-N01-D)
Testing the System Operation
Testing the Gasoline Fume Sensors
Maintenance
ln the Event of an Alarm
Repairing Xintex Gasoline Detection Components
ReturninB Xintex Gasoline Fume Detection Components
l Year Limited Warranty
2
Part Number 18140, D, 0L126/2017
3
3
4
6
6
6
6
7
7
7
7
8
8
8
9

l-
General lnformation
GASOLINE FUME DETECTORS ARE MEANT TO SERVE AS A SUPPLEMENTAL WARNING SYSTEM. IT
IS NOT MEANTTO REPLACE STANDARD SAFETY PRACTICES WHICH SHOULD BE CARRIED OUT
AROUND EXPLOSIVE GASES.
The G-18-R, G-1C-R, and G-28-R Gasoline Fume Detectors are an effective means to monitor
gasoline fumes in an engine compartments, leaking fuel tanks, or fumes from un-burnt
hydrocarbons emitted from faulty exhaust systems. The systems use sensors, located in a place of
interest, and a central display unitthat notifiesyou ofthe state ofthe system.
Specification
Svstem Specifications {G-1B-R/G-1C-R)
Operating Voltage: 9-30 VDC
Nominal Current Draw: 55mA @ 12 VDC
Maximum Current Draw:95mA @ 9 VDC
Operating Temperature: -40"F (-40"C) to 185"F (85'C)
Alarm Horn: = 68dB
Svstem Specifications (G-2 B-R)
Operating Voltage: 9-30 VDC
Nominal Current Draw:95mA @ 12 VDC
Maximum Current Draw: 150mA @ 9 VDC
Operating Temperature: -40"F (-40"C) to 185"F (85'C)
Alarm Horn: = 68dB
3
Part Number 18140, D, Ot/2612017

Operation of Xintex Gasoline Fume Detector(s)
There are 3 LEDs located on the Display unit for each channel on the system. The Green LED,
located at the top, indicates that the system is operational. The Yellow LED, located in the center,
indicates that there is a Fault in the system. This is to notify the user to check the connections
andwirerunsofthesensors. Theremaybeabreakinthewiringoradisconnectedsensoronthat
channel. The Red LED, located at the bottom, indicates a fume buildup of 20% of the LEL (Lower
Explosive Limit) which is considered an alarm. The alarm horn will sound when the Red LED is
illuminated.
GlBR-NO1-D
GlCR-NO1-D
The alarm status will continue as long as the fume level remains at an elevated level. The alarm
horn may be silenced by pressing the "Check/Reset" button. The alarm will reactivate after 30
seconds as long as the Detector remains in alarm status. The problem should never be considered
corrected as long as the Red LED is illuminated.
4
Part Number 1,8L4O, D,0l/26/2017
G2BS-NO1-D

q
t
-H-
Id
ffiE
g
I
tr
T3
ll s
HT
ol'1 6
ull r
rs
5tr1
o
d
o
z
co
N
(,
oo
til
oo
z.z
E. E.
(I)(J
dd
(,(9
5
Part Number 18140, D, 0U2612017
C
f
o
(,
I
:z
U
J
6

lnsta llation
lnstallins the Display Unit (G1BR-N01-D/G1CR-NO1-D or G2BS-N01-D)
The Display Unit should be located at the instrument panel, so that the visible and
audible indicators may be easily observed.
Drill a 2-L/L6" hole to accommodate the G1BR-N01-D/G1CR-N01-D Display Unit.
Drill a 2-L/8" hole to accommodate the G2BS-NO1-D Display Unit.
lnsert Display unit into hole and secure with the provided threaded mounting nut.
/IAKE TLTL II{ILAL LUNNTCTIONS AT THIS TIME. THEY WILL BE ADDRESSED IN A LATER
Routine Sensor Cable(s) (FS-XO1 CABLE XX')
A 20 FT sensor cable is provided for each Gasoline Fume sensor. The sensor cables
should be routed starting at the Display unit, then to the pre-determined location of the
Gasoline Fume sensor. connect to the Display unit using the attached quick-disconnect
connectors. Take care not to pinch, break, or cut the Sensor cable or put too much
stress on the connectors while routing the cable. secure the sensor cable with the
appropriate hardware for the application.
ELECTRICAL CONNECTIONS AT THIS
DO NOTCUT EXTENSION CABLE FOR ANY PURPOSE.
WARRANTY. LONGER CABLESARE AVAILABLE FROM DOING SO VOIDS THE PRODUCTS
20 FTTO 1OO FT.
lnstallins Gasoline Fume Sensor(s) (FS-T01)
TheGasolineFumesensorshouldbelocatedintheBilge,justabovethe"sloshLine". A
goodruleofthumbistoinstall nolowerthantheheightofthestartersolenoid. Avoid
locating sensors near manifold or exhaust systems, as high heat may damage the
sensor.
Use the appropriate #8 mounting hardware to mount the Gasoline Fume sensor in the
desired location. The rubber gasket should be installed between the sensor and the
mounting surface.
connect to the Extension cable using the attached quick-disconnect connectors.
6
Part Number L8140, D,01.126/20t7

lnstallation Continued
Electrical Connections (G1BR-N01-D/G1CR-N01-D or G2BS-N01-D)
The Display Unit operates on 9-30 VDC. A Red and a Black 16 GA wire are provided for
connecting to the power source. Connect the Red wire to Power (+) with an inline 1.0
Amp fuse. Connect the Black wire to Ground (-).
Testing the System Operation
The Gasoline Fume Detectors can be tested by pressing the "Check/Reset" button on the face of
the Display Unit. The Display Unit will cycle through the LEDs and the alarm horn will activate
while the LEDs cycle.
Unplug the Gasoline Fume Sensor from each channel of the Detection System. The Yellow "Fault"
LEDshouldilluminate. lftheYellowLEDdoesnotilluminate,removeDisplayUnitandreturn
direct to manufacturer following the instructions at the back of this manual'
Testing the Gasoline Fume Sensors
DO NOT USE A GASOLINE SOAKED RAG OR A PARTIALLY FULL CONTAINER OF GASOLINE TO TEST A
SENSOR. THE RAW GASOLINE COULD IGNITE, RESULTING IN SERIOUS INJURY.
TesttheSensorsbyholdinganunlitButanelightertothesensor. Withinafewseconds,theRed
"Danger" LED should illuminate and the alarm horn will sound. Remove the lighterfrom the
Sensor and mute the alarm horn. After approximately one minute, the Red LED will shut off.
Maintenance
The system should be tested periodically in the fashicn described in the previous sections. Due to
the harsh environmental conditions in marine applications, it is recommended to replace the
Gasoline Fume Sensors every 3-4 years.
7
Part Number 18140, D, 01126/2OL7
IMPROPER CONNECTIONS WILL DAMAGE THE DISPLAY UNIT AND WILL VOID WARRANTY.

ln the Event of an Alarm
lmmediately have all passengers and crew exit the passenger compartment and vessel if possible.
Ventilate the space being monitored.
Carefully check all fuel lines and other potential sources of gasoline fume leaks. lf leaks are
identified, shut off fuel supply and make any necessary repairs.
Repairing Xintex Gasoline Fume Detection Components
Xintex Gasoline Fume Detection Components are not field serviceable. Components must be
returned to the factory for any repairs.
Xintex Gasoline Fume Detection Components
No product may be returned for credit or repair without a written "Returned Material
Authorization" (RMA) form. Purchaser must call or email Fireboy-Xintex 616-735-9380 or
returned,afterapproval itmustbereceivedinL00%new/resalablecondition. Productsstoredby
the buyer for more than 26 weeks may not be returned for any reason. Maintaining fresh and
current inventory is the responsibility of the buyer.
8
Part Number 18L40, D, 01./26/20L7

L Year Limited WarrantY
This Warranty is in lieu of all other expressed or implied Warranties
seller warrants title, materials, and workmanship on equipment, except components
manufactured by others for which the Seller assigns, as permitted, the original manufacturer's
warranty. Seller's warranty shall be for a period of (1) one year from the date of sale to the
ORIGINAL CONSUMER PURCHASER, during which non-conforming equipment returned to the
Seller at Buyer's expense and risk, be repaired or replaced at the Seller's option. Fireboy-Xintex,
lnc. will repair or replace products found to be defective in materials or workmanship within the
period setforth above, provided that: (a) the product has not been subjected to abuse,
contamination, neglect, accident, incorrect wiring not our own, improper installation or servicing,
or used in violation of instructions furnished by Fireboy-Xintex, lnc. and (b) as to any prior defects
in materials orworkmanship covered by this warranty, the product has not been repaired or
altered by anyone except Fireboy-Xintex, lnc and (c) the serial number has not been removed,
defaced or otherwise changed, and (d) examination discloses, in the judgment of Fireboy-Xintex,
lnc., does not assume the costs of removal and/or installation of the product or any other
incidental costs of removal and/or installation of the product or any other incidental costs which
mayariseasaresult of anydefectinmaterial orworkmanship,and(e) upondiscoveryof defect,
Buyer shall immediately cease use of and notify Fireboy-Xintex, lnc'
Any warranty implied by law, including warranties of merchantability or fitness, is in effect only
forthe duration ofthe expressed warranties setforth above, no person is authorized to give any
other warranty, or to assume for Fireboy-Xintex, lnc. any other liability in connection with the sale
of its products; Fireboy-Xintex, lnc. shall not be liable for the loss of use, revenue, or profit or for
any injury, or for any other consequential or incidental damages, buyer is not relying on seller's
judgmentregardinghisorher particularrequirements,andhashadanopportunitytoinspectthe
product to his or her satisfaction'
This warranty gives you specific legal rights, and you may also have other rights, which vary, from
state to state.
www.fi reboy-xi ntex.com
Fireboy-Xintex, lnc.
0-379 Lake Michigan Dr. NW
Grand Rapids, Ml 49534
fi reboy@fi re boy-xintex.com
Phone (616) 735 9380
FireboY-Xintex, LTD
L0 Holton Road, Holton Heath Trading Park
Poole Dorset BH16 6LT UK
fi reboyeu @fi reboY-xi ntex.com
Phone 44 (0) 845 9462
9
Part Number 18140, D, 0U2612017
--
This manual suits for next models
5
Table of contents