Xpelair Premier DX180H User manual

What you will need need .
•To fix these fans through a wall you will need“Wall Vent Kit VK10”.
•To fix these fans through a glass window or panel you will need
“Glass Mounting Kit GMK”
•To fix these fans through a ceiling you will need
"Ceiling Mounting Kit XCMK”.
•A double pole isolating switch with a minimum contact gap of 3mm.
•Suitably rated 3-core or 4-core cable.
•A ceiling or wall on/off switch with built in indicator (DX180T/DX180H)
If installing in a wall (surface mounting) )
1. Mark on the wall the centre of the duct holeA.
2. Use this centre to cut an opening through the wall Ø117mm,with a
slight fall to the exterior.
3. Fit the wall tube (not supplied) and mortar into place.
If installing in a wall (flush mounting)) )
1. Mark on the wall the centre of the duct holeA, and drill a pilot hole
through both walls at a slight downward angle.
2. Use the centre to mark a rectangular hole for the inner wall using
the dimensionsA.
3. Cut the rectangular hole through the inner wall.
4. Go outside and cut a Ø117mm hole in the outer wall using the
small hole as the centre.
5. Measure the wall thickness. Cut the wall tube, not supplied, so that
it is 64mm less than the wall thickness
If installing in a ceiling (surface mounting) )
This method requires aspace above the ceiling, such as aloft or attic,
to provide access for 100mm internal diameter ducting.
1. Mark on the ceiling the centre of the duct holeA, avoiding ceiling
joists and buried cables etc.
2. Cut a Ø117mm hole using the marked centre.
If installing in a ceiling (flush mounting) )
For Ø100mm ducting:
1. Mark a rectangular hole using the dimensions B.
2. Cut the hole, avoiding ceiling joists and buried cables etc.
For flat ducting:
•This fan can be installed within a 47mm void without the circular
spigot6 (Fig.E). Flat ducting adapter (FDA) available.
Preparing the fan for installation n
1. Remove the front cover1 (Fig.C)
2. Fit the foam tape9around the circular spigot6(Fig.E).
3. Remove the electrical cover4 (Fig.E). The impeller 2can be
removed to aid access (if required). This is a “push-on/pull-off”
assembly.
Mounting the fan in a wall or ceiling (surfacemounting)
1. Place the ducting into the hole and align to the required position.
If wall mounting, ensure that the ducting slopes down and way from
the fan
2. Mark the positions of the threefixing holes Ain fan box 5(Fig.E).
3. If wall mounting, drill three holes 5.5mm diameter for wall plugs.
If ceiling mountingB, use suitable fasteners (not supplied).
4. Cut out the cable inlet hole, if required, in the surround10 and slit
the cable grommet. Slide the surround10 over the fan box 5.
5. Pass the electrical cables into the fan box5through the rear cable
inlet hole and re-fit the cable grommet.
Ensure that cable grommet is in place and a tight fit.
6. Offer the fan box5up to the wall or ceiling. Ensure the circular
spigot6enters the ducting.
7. Fix the fan box5to the wall using suitable screws or to the ceiling
using appropriate fasteners (not supplied).
8. If mounting in a wall (flush mounting) )
The surround10is not required.
Fit the ducting to the circular spigot6.
1. Assemble the three fan body clamps8to the fan box 5 using
suitable screws.
2. Slit the cable grommet. Pass the electrical cables into the fan box5
through the cable inlet hole and cable grommet.
Ensure cable grommet is in place and a tight fit.
3. Offer the fan box5up to the wall.
4. Tighten up the three screws, until the fan is clamped to the inner
wall. The fan body clamps8will rotate to an automatic stop
position. DO NOT OVERTIGHTEN.
If mounting in a ceiling (flush mounting) )
The surround10is not required.
1. Insert the fan box5 into the hole and mark four positions using the
slots in the flangeB.
2. Remove the fan box5from ceiling and fit four suitable ceiling clips
over the edge of the hole, so that the clips align with the marks on
the ceiling B.
3. Drill 4 pilot holes into the ceiling through the hole of each clip,
ensuring not to damage the clip, and fit the clips ensuring correct
alignment.
4. Fit the ducting to the circular spigot6.
5. Offer the fan box5up to the ceiling.
6. Slit the cable grommet. Pass the electrical cable into the fan box5
through the front cable inlet hole.
Ensure cable grommet is in place and a tight fit.
7. Usingsuitable screws11(Fig.B), fix the fan box flange to the ceiling
clips.
Terminating the ducting g
Fit an outer grille to the outer wall.
For ceiling mounting, use appropriate ancillaries.
Wire the electrical connections s
WARNING: THIS APPLIANCE MUST BE EARTHED
1. Isolate the electricity supply and remove all fuses.
The terminal block will accept cable up to 2.5mm²
2. Use a double-pole isolating switch with a minimum contact gap of
3mm in both poles.
3. Use suitably rated 3-core or 4-core cable dependant on application.
4. Remove the retaining screws of the terminal cover4, if still in
position.
5. Wire the fan as shown inFusing the cable clamp provided. Check
fan model to diagram.
6. Replace the terminal cover4and fasten the retaining screws.
7. See section on“User adjustments”if you wish to use settings other
than those that have been factory set.
8. Refit the front cover1(Fig.C).
9. Connect the cable from the isolating switch to electrical supply
wiring, and re-check installation.
10.Refit fuses before turning on electricity supply.
11.For fixed wiring circuits, the protective fuse for the appliance must
not exceed 5A.
For Australia Only
Permanently connected to the supply and aremote switch controls
operation. They should be directly wired to the supply through an
approved 10A wall mounted surface switch with at least 3mm
clearance between contacts.
User adjustments .
Before making any adjustments, isolate the fan completely from
the mains supply, check specification below to see which features
apply to your fan.
1. Remove the front cover and replace after adjustment (Fig.C)
Premier DX180 .
• There are no user adjustments for this fan.
Premier DX180T .
• There are no user adjustments for this fan.
Premier DX180H .
• The humidity setting is adjustable between approximately 50% and
90% relative humidity. Use an electrician’s screwdriver,and turn
screw “RH”(Fig.D), clockwise to increase the relative humidity
setting and anti-clockwise to decrease.
(Note: the fan is more sensitive at 50% RH than at 90% and is
factory set at approximately 70%).
Using the fan .
Premier DX180 .
Operate the fan using the external on/off switch. Repeat to switch off.
Premier DX180T .
Operate the fan using the external on/off switch. Repeat to switch off.
When the switch is turned off, the fan continues to operate for the
over-run timer period. (Fixed at approximately 20 minutes).
Premier DX180H .
Switched Operation
The fan can be wired with a separate on/off switch. Fan operates at
condensation speed when switched on. When switched off, the fan will
continue to operate if the humidity level exceeds the set level.
Condensation Operation
The fan operates at condensation control speed, when the relative
humidity exceeds the set level, and turns off when the humidity drops.
Cleaning g
1. Before cleaning, isolate the fan completely from the mains
supply
2. Only clean the external surface of the fan, using a damp lint free
cloth.
3. Do not use strong detergents, solvents or chemical cleaners
4. Allow fan to dry thoroughly before use.
5. Apart from cleaning, no other maintenance is required
Key See Diagram EE
1. Front Cover
2. Impeller
3. Screws
4. Terminal Cover
5. Fan Box
6. Circular Spigot
7. Clamp Screws and Wall Plugs
8. Fan Body Clamps
9. Foam Tape
10. Surround
11. Ceiling Screws (Diagram B)
Guarantee e
UK: This fan is guaranteed against defects for 2 years from the date of
purchase
• Xpelair reserve the right to repair or replace the fan
• Keep your purchase receipt
• Any problems, contact the address below
Outside UK: See International section below
Technical Advice & Service e
UK - Xpelair have a comprehensive range of services including:
• Free technical advise Help-Desk from Engineers on all aspects of
ventilation.
• Free design service, quotations and site surveys
Outside UK: See International section below
Please ask for details on:
Tel: +44 (0) 8709 000430
Fax: +44 (0) 8709 000530
Also at the address below
Head Office – UK Sales Office and Spares s
Applied Energy Products Ltd,
Morley Way, Peterborough, PE2 9JJ, England
Tel: +44 (0) 1733 456789
Fax: +44 (0) 1733 310606
Sales/Spares Hotline: +44 (0) 8709 000420
Sales/Spares Faxline: +44 (0) 8709 000520
Web: http://www.xpelair.co.uk
International s
Guarantee– Contact your local distributor or Xpelair direct
IMPORTANT
• READ ALL THESE INSTRUCTIONS & WARNINGS FULLY BEFORE
COMMENCING INSTALLATION.
• INSTALLATIONS AND WIRING MUSTCONFORM TO CURRENTIEE
REGULATIONS (UK), LOCAL OR APPROPRIATE REGULATIONS (OTHER
COUNTRIES). ITIS THE INSTALLER’S RESPONSIBILTY TOENSURE THAT
THE APPROPRIATE BUILDING CODES OF PRACTICE ARE ADHERED TO.
• AQUALIFIED ELECTRICIAN MUSTSUPERVISE ALL INSTALLATIONS.
• THESE APPLIANCES ARE INTENDED FOR CONNECTION TO FIXED
WIRING
• CHECK THATTHE ELECTRICAL RATING SHOWN ON THE FAN MATCHES
THE MAINS SUPPLY.
• WARNING: THESE APPLIANCES MUSTBE EARTHED.
• SITE AWAY FROM DIRECTSOURCES OF HEAT(I.E.: GAS COOKERS OR
EYE-LEVEL GRILLS) AND NOTWHERE AMBIENTTEMPERATURES ARE
LIKELY TO EXCEED 50 OC.
• WHEN THE FAN IS INSTALLED IN AROOM CONTAINING AFUEL
BURNING APPLIANCE, PRECAUTIONS MUSTBE TAKEN TO AVOID THE
BACKFLOW OF GASES INTO THE ROOM FROM THE OPEN FLUE OF THE
FUEL BURNING APPLIANCE
• ENSURE THATALL RELEVANTSAFETY PRECAUTIONS (CORRECTEYE
PROTECTION AND PROTECTIVE CLOTHING ETC) ARE TAKEN WHEN
INSTALLING, OPERATING AND MAINTAINING THIS FAN.
• IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THANTHE
FAN ACONDENSATION TRAP (XCT100) MUSTBE FITTED AS CLOSE AS
POSSIBLE TO THE FAN
• GENERAL GUIDANCE FOR SITING THE FAN SEE “FIG.G”. ALWAYS SITE
FAN AS HIGH AS POSSIBLE
• THE APPLIANCE IS NOTINTENDED FOR USE BY YOUNG CHILDREN OR
INFIRM PERSONS. YOUNG CHILDREN SHOULD BE SUPERVISED TO
ENSURE THEY DO NOTPLAY WITH THE APPLIANCE
FM11408 - QAS 3284/37
PREMIER DX180 RANGE Centrifugal Bathroom Fan
Installation and Operating Instructions
Please leave this leaflet with the fan for the benefit of the user
Leaflet No. 567-2068-04A

This manual suits for next models

2

Other Xpelair Fan manuals

Xpelair XPSS Quick reference guide

Xpelair

Xpelair XPSS Quick reference guide

Xpelair SSSFC100 Instruction Manual

Xpelair

Xpelair SSSFC100 Instruction Manual

Xpelair Xpelair C100T User manual

Xpelair

Xpelair Xpelair C100T User manual

Xpelair GX12 User manual

Xpelair

Xpelair GX12 User manual

Xpelair CMF171 User manual

Xpelair

Xpelair CMF171 User manual

Xpelair Simply Silent C4S User manual

Xpelair

Xpelair Simply Silent C4S User manual

Xpelair Ripple Standard 4" User manual

Xpelair

Xpelair Ripple Standard 4" User manual

Xpelair GX6EC User manual

Xpelair

Xpelair GX6EC User manual

Xpelair Simply Silent C4S User manual

Xpelair

Xpelair Simply Silent C4S User manual

Xpelair XPP User manual

Xpelair

Xpelair XPP User manual

Xpelair GX9 and User manual

Xpelair

Xpelair GX9 and User manual

Xpelair Simply Silent C4SR User manual

Xpelair

Xpelair Simply Silent C4SR User manual

Xpelair VX100 User manual

Xpelair

Xpelair VX100 User manual

Xpelair Simply Silent C4S User manual

Xpelair

Xpelair Simply Silent C4S User manual

Xpelair Simply Silent CV Series User manual

Xpelair

Xpelair Simply Silent CV Series User manual

Xpelair XIDP User manual

Xpelair

Xpelair XIDP User manual

Xpelair CX10 User manual

Xpelair

Xpelair CX10 User manual

Xpelair SLDC100 User manual

Xpelair

Xpelair SLDC100 User manual

Xpelair XP15E Quick reference guide

Xpelair

Xpelair XP15E Quick reference guide

Xpelair Natural Air PH 180 User manual

Xpelair

Xpelair Natural Air PH 180 User manual

Xpelair XPA360CF Quick reference guide

Xpelair

Xpelair XPA360CF Quick reference guide

Xpelair VX100 User manual

Xpelair

Xpelair VX100 User manual

Xpelair Natural Air Series User manual

Xpelair

Xpelair Natural Air Series User manual

Xpelair PX12 User manual

Xpelair

Xpelair PX12 User manual

Popular Fan manuals by other brands

Faro Barcelona Timor manual

Faro Barcelona

Faro Barcelona Timor manual

Envirovent PIV Installation and user guide

Envirovent

Envirovent PIV Installation and user guide

Ortech OD22025 manual

Ortech

Ortech OD22025 manual

Fanaway EVO3 Installation instructions manual

Fanaway

Fanaway EVO3 Installation instructions manual

Acqua AC-MGD2 instruction manual

Acqua

Acqua AC-MGD2 instruction manual

Fanimation Evanesce FP2700 Series owner's manual

Fanimation

Fanimation Evanesce FP2700 Series owner's manual

Casablanca Isotope owner's manual

Casablanca

Casablanca Isotope owner's manual

Craftmade Monaghan MGN52AO installation guide

Craftmade

Craftmade Monaghan MGN52AO installation guide

Vents TwinFresh Comfo RA1-50 user manual

Vents

Vents TwinFresh Comfo RA1-50 user manual

KDK W56WV Operating and installation instructions

KDK

KDK W56WV Operating and installation instructions

Monte Carlo Fan Company 5AB52XX Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5AB52XX Series Owner's guide and installation manual

Vivax FS-40WTB user manual

Vivax

Vivax FS-40WTB user manual

Alpha Fan Heritage instruction manual

Alpha Fan

Alpha Fan Heritage instruction manual

Attwood 9040-4 instruction manual

Attwood

Attwood 9040-4 instruction manual

Trotec TTW-25000S operating manual

Trotec

Trotec TTW-25000S operating manual

Lasko 4910 Important instructions & operating manual

Lasko

Lasko 4910 Important instructions & operating manual

Modern Forms ELF installation instructions

Modern Forms

Modern Forms ELF installation instructions

Mitsubishi KD-32DTD Use & care manual

Mitsubishi

Mitsubishi KD-32DTD Use & care manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.