FEATURES
Switch on/off S-Digit Multi
Current reading will be frozen by pressing
HOLD
Press 1x shortly = light on
Press 1x long = sound on
0° and 90° position of inclination will be
confirmed by a signal tone
Set reading of display to degrees (°) or percent
(%)
Switch on/off laser beam
Calibration - see instructions below
Battery status - batteries have to be replaced if
lamp is flashing
K T CONS STS OF
Electronic slope measurer S-Digit Multi, padded bag,
batteries, user’s manual
FUNCT ONS
Electronic slope measurer, for measuring inclinations,
slopes and plane surfaces
TECHN CAL DATA
Working range 0 - 360°
Resolution 0.1° or 0.1%
Accuracy 0° + 90° = ±0.1°
1° - 89° = ±0.2°
Power supply 3x 1.5V AAA
Operating time 600h
Wavelength 650nm
Laser class 2
Laser output power <1mW
Accuracy laser
vertical ±0.3mm/m
horizontal ±2mm/m
Temperature range -10°C to +45°C
Size 250 x 30 x 55mm
Weight 0.56kg incl. batteries
MPORTANT
Calibration of inclinometer:
- calibrate before first use
- before important measurements
- after a hit or drop
- after a large fluctuation in temperature
CHECK OF HOR ZONTAL CAL BRAT ON
Lay down unit to a flat horizontal surface (fig. 1).
Switch on and note down value of measured
inclination. Turn unit by 180° (fig. 2) and note down
measured value. f deviation between two values is
more than 0.2° instrument has to be calibrated.
CHECK OF VERT CAL CAL BRAT ON
Lay down unit to a flat vertical surface
(fig. 3). Switch on and note down value
of measured inclination. Turn unit by
180° (fig. 4) and note down measured
value. f deviation between two values
is more than 0.2° instrument has to be
calibrated.
HOR ZONTAL CAL BRAT ON
Lay down unit on a flat horizontal surface (fig. 5) and
switch unit on. Press ZERO (display shows „0”). Wait
10 sec, press ZERO again (display shows „1”). Turn
unit by 180° (fig. 6), wait 10 sec and press ZERO
(display shows „2”) => calibration process completed.
Now unit starts measuring automatically.
VERT CAL CAL BRAT ON
Lay down unit on a flat vertical surface (fig.
7) and switch unit on. Press ZERO (display
shows „0”). Wait 10 sec, press ZERO
again (display shows „1”). Turn unit by
180° (fig. 8), wait 10 sec and press ZERO
(display shows „2”) => calibration process
completed. Now unit starts measuring
automatically.
MEASUREMENT OF NCL NAT ON
Switch on S-Digit Multi. Measured inclination value is
shown in degrees (°) - can be changed to percent
(%) by pressing button „°/%”. Lay unit on surface with
blank bottom side only. The 2 arrows in the display
indicate which direction S-Digit Multi has to be moved
in order to reach 0° or 90° position.
0° - 45.0° Leading to 0° position
45.1° - 90° Leading to 90° position
The exact „0” position is shown by double arrows.
Display has automatic digit inversion for overhead
measurements. Reading of measured values is
possible in every position.
SPEC AL APPL CAT ON
S-Digit Multi has a rotatable display which can be
turned within a range of 180°.
Batteries
Open the battery compartment cover and put in
batteries (take care of polarity).
mportant: Battery symbol flashes when batteries
need to be replaced.
Connection to camera tripod
With the ¼” thread (at bottom side) S-Digit Multi can
be connected to a camera tripod.
Laser classification
• The instrument is a laser class 2 laser product
according to D N EC 60825-1:2003-10.
• t is allowed to use unit without further safety
precautions.
• Eye protection is normally secured by
aversion responses and blink reflex.
Laser class 2 warning labels on the >>
laser instrument.
Care and Cleaning
• Please handle measuring instruments with care.
• Clean with soft cloth only after any use. f necessary
damp cloth with some water.
• f instrument is wet clean and dry it carefully. Pack it
up only if it is perfectly dry.
• Transport in original container/case only.
Safety nstructions
• Please follow instructions given in operator’s
manual.
• Use instrument for measuring jobs only.
• Do not open instrument housing. Repairs should be
carried out by authorised workshops only. Please
contact your local dealer.
• Do not remove warning labels or safety instructions.
• Keep instrument away from children.
• Do not use instrument in explosive environments.
CE-Conformity
nstrument has CE-mark according to EN
61326:1997, EN 55022, EN 61000-4-2/-3.
Electromagnetic Acceptability (EMC)
• t cannot be completely excluded that this
instrument will disturb other instruments (e.g.
navigation systems).
• will be disturbed by other instruments (e.g. intensive
electromagnetic radiation, nearby industrial facilities
or radio transmitters).
Specific Reasons for Erroneous Measuring Results
• Measurements through glass or plastic windows.
• Dirty laser emitting windows.
• After instrument has been dropped or hit. Please
check accuracy.
• Large fluctuation in temperature: f instrument will
be used in cold areas after it has been stored in
warm areas (or vice versa) please wait some
minutes before carrying out measurements.
Warranty
• The product is warranted by the manufacturer to the original
purchaser to be free from defects in material and workmanship under
normal use for a period of two (2) years from the date of purchase.
• During the warranty period, and upon proof of purchase, the product
will be repaired or replaced (with the same or similar model at
manufacturer’s option), without charge for either parts or labour.
• n case of a defect please contact the dealer where you originally
purchased this product. The warranty will not apply to this product if it
has been misused, abused or altered. Without limiting the foregoing,
leakage of the battery, bending or dropping the unit are presumed to
be defects resulting from misuse or abuse.
Exceptions from Responsibility
• The user of this product is expected to follow the instructions given in
operator’s manual. Although all instruments left our warehouse in
perfect condition and adjustment the user is expected to carry out
periodic checks of the product’s accuracy and general performance.
• The manufacturer or its representatives assumes no responsibility of
results of a faulty or intentional usage or misuse including any direct,
indirect, consequential damage and loss of profits.
• The manufacturer or its representatives assumes no responsibility for
consequential damage and loss of profits by any disaster (earthquake,
storm, flood, etc.), fire, accident or an act of a third party and/or a
usage in other than usual conditions.
• The manufacturer or its representatives assumes no responsibility for
any damage and loss of profits due to a change of data, loss of data
and interruption of business etc. caused by using the product or an
unusable product.
• The manufacturer or its representatives assumes no responsibility for
any damage and loss of profits caused by usage other than explained
in the user’s manual.
• The manufacturer or its representatives assumes no responsibility for
damage caused by wrong movement or action due to connecting with
other products.
10/2007