manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. York Survey Supply
  6. •
  7. Measuring Instrument
  8. •
  9. York Survey Supply 33235 User manual

York Survey Supply 33235 User manual

Code: 33235
Operating
Instructions
Ref:.. \operat98\instructions 18\33235.qxp 05-01-18 ©York Survey Supply Centre 2018
Prospect House
George Cayley Drive
Clifton Moor
York
England
YO30 4XE
Tel: +44 (0) 1904 692723
Fax: +44 (0) 1904 690385
E-Mail: sales@yorksurvey.co.uk
...for secure online ordering of all our products!
Nothing else measures up!
Skywatch
Meteos Anemometer
©York Survey Supply Centre 2018Ref:.. \operat98\instructions 18\33235.qxp 05-01-18
Skywatch Meteos
You have just acquired a piece of high precision equipment which has been created using the most
modern technology. It has been designed to stand up to intensive use. However, in order to maintain its
appearance and its precision, we recommend that you treat it with care and read this manual carefully.
Functions of the buttons
Configura-
tion
To access the configuration mode of your instrument, just press on the button. Pressing the
button once again causes the system to confirm the setting have been changed. If not then it goes to the
next setting. To modify the settings the and buttons have to be used. The next page instructs you on
how to set up the different instrument settings.
Wind Measuring Units
The units to be selected are: knots, km/h, m/s, fps and bft. Once the unit is chosen, it remains displayed
in the top right of the screen. If no other unit is chosen the instrument is set to the Beaufort.
Temperature Measuring Units
The units to be selected are °C, °F, °C and °F
Setting the time of the average
The times selected are: ---(weighting), 3”, 6”, 12”, 30”, 1’, 6’, 30’, 1:00’, 6:00’, 12:00’, 24:00’, or timer. The
timer mode allows measurements of the average between start (press ) and stop (press ). This time
is displayed on the lower lines. This timer allows the use of the LapTime function (press the symbol
flashes). The button also allows the timer to be reset to zero. This works in the same way as a
standard chronometer.
Setting the wind and temperature displays
The displays to be selected are: ---, MIN, AV, MAX. If AV is selected the average of temperature and wind
are shown. The display of average windspeeds is always made simultaneously for the wind (at the
centre) and temperature (at the bottom). The other modes (---, MIN, MAX) only concern the
temperature.
Setting the display is not possible if the units selected are °C or °F .
Measuring the wind
Important: The protective cap has to be removed from the instrument in order to rotate the impeller. The
impeller has a maximum sensitivity in the vertical position (due to its magnetic levitation), and an
optimised precision when its axis of rotation is perpendicular to the wind direction.
Instantaneous wind speed (top of the screen)
Maximum wind speed (centre of the screen)
The display of the maximum wind speed is made at the central part. It is the
maximum measured value of the time of the average. The value is reset to zero during a RESET of the
memory.
Measuring the temperature
Instantaneous temperature
Important: Thermal inertia of the instrument directly affects the stabilisation time of the measurement.
The greater the temperature difference is the longer the this time will be. This time will be shorter if the
windspeed is higher.
Wind-chill temperature
As you know, exposure to low temperatures is potentially dangerous to the human body. But did you
know that wind plays an important part in how your body actually feels temperatures? For example, an
ambient temperature of 0°C and a 30km/h wind have the same effect on you as a temperature of -13°C!
The result of the calculation of the effect of wind on the temperature is called the “wind-chill
temperature”. By the sea, in the mountains, hiking or cycling, the Skywatch Meteos shows immediately
the temperature felt by the body and warns of risks of chilblains and hypothermia.
Min and max temperature
These two modes show the min or max values measured over time of the average. The value is reset to
zero during a RESET of the memory. These values are not those of the temperature felt by the body.
Technical Data
• Sealed and weatherproof instrument
• Thread on the bottom of the instrument for fixing to a tripod (1/4”)
• Anemometer Precision: ±3%, depending on its orientation in the wind
• Anemometer Resolution: 0.1 for all units
• Thermometer Precision: ±0.2°C
• Thermometer Resolution: 0.1°C
• Power Supply: 2x 1.5v AA batteries
• Battery Lifetime: At least 3 years with occasional use of the display backlight. To
replace, loosen the three screws on the metal plate.
• Weight: 235g (insubmerisible)
• Dimensions: Ø65 x 155mm
The wind measuring principle of the S YWATCH METEOS is based on the detection of a rotating
magnetic field produced by an impeller. If the device is subject to a strong field produced by a
transformer or motor, if may happen that the instrument shows undesirable values, without any
rotation from the impeller.
ON: Press for 1 second
OFF: Press for 2 seconds (not auto off)
LIGHT: Press on and off briefly
UP: Setting mode
START/STOP: Chronometer mode
DOWN: Setting mode
LAP/RESET: Chronometer mode
SET/CAL: Setting mode
RESET MEMORY: Press for 3 seconds

Other York Survey Supply Measuring Instrument manuals

York Survey Supply 343660 User manual

York Survey Supply

York Survey Supply 343660 User manual

York Survey Supply 354910 User manual

York Survey Supply

York Survey Supply 354910 User manual

York Survey Supply 354420 User manual

York Survey Supply

York Survey Supply 354420 User manual

York Survey Supply 33065 User manual

York Survey Supply

York Survey Supply 33065 User manual

York Survey Supply 354820 User manual

York Survey Supply

York Survey Supply 354820 User manual

York Survey Supply 343520 User manual

York Survey Supply

York Survey Supply 343520 User manual

York Survey Supply 343010 User manual

York Survey Supply

York Survey Supply 343010 User manual

York Survey Supply S-Digit Mini+ 263040 User manual

York Survey Supply

York Survey Supply S-Digit Mini+ 263040 User manual

York Survey Supply 343300 User manual

York Survey Supply

York Survey Supply 343300 User manual

York Survey Supply 343090 User manual

York Survey Supply

York Survey Supply 343090 User manual

York Survey Supply 261640 User manual

York Survey Supply

York Survey Supply 261640 User manual

York Survey Supply 343000 User manual

York Survey Supply

York Survey Supply 343000 User manual

York Survey Supply 263090 User manual

York Survey Supply

York Survey Supply 263090 User manual

York Survey Supply 33245 User manual

York Survey Supply

York Survey Supply 33245 User manual

York Survey Supply 330550 User manual

York Survey Supply

York Survey Supply 330550 User manual

York Survey Supply 343680 User manual

York Survey Supply

York Survey Supply 343680 User manual

York Survey Supply 346010 User manual

York Survey Supply

York Survey Supply 346010 User manual

York Survey Supply Pro Sport 850 User manual

York Survey Supply

York Survey Supply Pro Sport 850 User manual

York Survey Supply 37135 User manual

York Survey Supply

York Survey Supply 37135 User manual

York Survey Supply 354920 User manual

York Survey Supply

York Survey Supply 354920 User manual

York Survey Supply 34302 User manual

York Survey Supply

York Survey Supply 34302 User manual

Popular Measuring Instrument manuals by other brands

PCB Piezotronics T356A35 Installation and operating manual

PCB Piezotronics

PCB Piezotronics T356A35 Installation and operating manual

Hanna Instruments PCA 311 instruction manual

Hanna Instruments

Hanna Instruments PCA 311 instruction manual

LIMIT LDM 80 operating manual

LIMIT

LIMIT LDM 80 operating manual

Amprobe LM-100 user manual

Amprobe

Amprobe LM-100 user manual

GANN HYDROMETTE BL Compact TF-IR 2 operating instructions

GANN

GANN HYDROMETTE BL Compact TF-IR 2 operating instructions

Sensit HXG-3 Quick start instructions

Sensit

Sensit HXG-3 Quick start instructions

Tecfluid FLOMID Series instruction manual

Tecfluid

Tecfluid FLOMID Series instruction manual

Keysight Technologies 86120B user guide

Keysight Technologies

Keysight Technologies 86120B user guide

Kirchner und Tochter SGK 1-3 Assembly and operating instructions

Kirchner und Tochter

Kirchner und Tochter SGK 1-3 Assembly and operating instructions

Fluke 93 Service manual

Fluke

Fluke 93 Service manual

TQ Environmental TQ8000 operating manual

TQ Environmental

TQ Environmental TQ8000 operating manual

TSI Incorporated VELOCICALC Plus 8383 Operation and service manual

TSI Incorporated

TSI Incorporated VELOCICALC Plus 8383 Operation and service manual

Svantek SV 104BIS user manual

Svantek

Svantek SV 104BIS user manual

Spectrum Technologies Field Scout CM1000 Operation manual

Spectrum Technologies

Spectrum Technologies Field Scout CM1000 Operation manual

Remberg ENERGY-0-RS user manual

Remberg

Remberg ENERGY-0-RS user manual

RMS CMM96-MD user manual

RMS

RMS CMM96-MD user manual

Ateg CUB5V quick start guide

Ateg

Ateg CUB5V quick start guide

Rinstrum C300 Series Reference manual

Rinstrum

Rinstrum C300 Series Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.