R. M. YOUNG COMPANY 2801 Aero Park Drive , Traverse City, Michigan 49686 USA
TEL (231) 946-3980 FAX (231) 946-4772
MODEL 41342
PLATINUM TEMPERATURE PROBE
INSTRUCTION SHEET 41342-90
REV: C111215
INTRODUCTION
The Model 41342 Platinum Temperature Probe is an accurate 1000
ohm Platinum temperature sensor mounted in a weatherproof junction
box. The sensor output uses a 4 wire RTD conguration. The probe
is designed for easy installation in YOUNG Multi-plate and Aspirated
Radiation Shields.
INSTALLATION
For accurate measurements, the temperature probe should be installed
in a protective radiation shield. Use of the probe without a radiation
shield may result in large errors. YOUNG naturally ventilated or motor
aspirated shields are recommended. For best performance, the probe
and shield should be placed in a location with good air circulation clear
of large masses (buildings, pavement, solar panels...), Exhaust vents,
electrical machinery, motors, water fountains and sprinklers.
NOTE: The terminal marked "EARTH GND" should be connected to
properly grounded tower, or grounding conductor, as close to the sensor
as possible. Failure to do so may result in damage due to static discharge.
MAINTENANCE
The temperature probe is designed to offer years of service with minimal
maintenance. If necessary, the probe may be periodically checked or
recalibrated using normal bath calibration methods. NIST traceable
calibration is available from YOUNG at nominal cost.
WARRANTY
This product is warranted to be free of defects in materials and
construction for a period of 12 months from date of initial purchase.
Liability is limited to repair or replacement of defective item. A copy
of the warranty policy may be obtained from R. M. Young Company.
CE COMPLIANCE
This product has been tested and complies with European CE
Requirements for the EMC Directive. Please note that shielded cable
must be used.
EMC COMPLIANCE
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à Ia norme NMB-001 du Canada.
EN55011/CISPR 11, Group 1, Class B device.
Class B equipment is suitable for use in domestic establishments and
in establishments directly connected to a low voltage power supply
network which supplies buildings used for domestic purposes.
SPECIFICATIONS
Calibrated measuring range: -50 to +50°C (sufx C)
-50 to +150°F (sufx F)
Accuracy at 0°C: ±0.3°C
±0.1°C (optional)
Time Constant: 42 seconds in 43502 shield.
Sensor type: 1000Ω Platinum RTD
Output signal: 4 wire RTD
Recommended Cable: 2 pair shielded
22 AWG (#18723)
Recommended Radiation Shields:
Model 43502 Aspirated Radiation Shield
Model 41003P Multi-Plate Radiation Shield
5.0 in
[125 mm]
7.1 in
[176 mm]
.94 in
[24 mm]
2.5 in
[
64 mm]
SHEATH
VENT
JUNCTION
BOX
CABLE
GLAND
SERIAL
NUMBER
R. M. YOUNG COMPANY
2801 Aero Park Drive , Traverse City, Michigan 49686 U.S.A.
TEL (231) 946-3980 FAX (231) 946-4772








WIRING INFORMATION
MODEL 41342 TEMPERATURE SENSOR
Resistance vs. Temperature for 1000 Ω nominal probe
Temperature Coefcient = 0.00375 Ω /Ω /°C
1226.445 140
1205.659 130
1184.837 120
1163.978 110
1143.081 100
1122.148 90
1101.177 80
1080.169 70
1059.124 60
1038.042 50
1016.922 40
995.766 30
974.572 20
953.340 10
932.069 0
910.759 -10
889.407 -20
868.013 -30
846.576 -40
825.093 -50
Resistance °F
Ω
60 1226.445
50 1189.005
40 1151.445
30 1113.764
20 1075.963
10 1038.042
0 1000.000
-10 961.837
-20 923.550
-30 885.132
-40 846.576
-50 807.873
Transfer function calculated from manufacturer's data:
C° = (1.1279x10-5
* R2) + (2.3985x10-1
* R) - 251.1326
F° = (2.0302x10-5
* R2) + (4.3174x10-1
* R) - 420.0387
NOTE: The terminal marked "EARTH GND"
should be connected to properly grounded tower,
or grounding conductor, as close to the sensor as
possible. Failure to do so may result in damage
due to static discharge.
°C Resistance
Ω

Popular Temperature Controllers manuals by other brands

Parker Sporlan TCB quick start guide

Parker

Parker Sporlan TCB quick start guide

ILX Lightwave LDT-5416 user guide

ILX Lightwave

ILX Lightwave LDT-5416 user guide

Autonics KPN Series User Manual for Communication

Autonics

Autonics KPN Series User Manual for Communication

Euroclima Radiotactil user manual

Euroclima

Euroclima Radiotactil user manual

i-therm AI-7482D User's operating manual

i-therm

i-therm AI-7482D User's operating manual

VOLTCRAFT ECB-1000P operating instructions

VOLTCRAFT

VOLTCRAFT ECB-1000P operating instructions

MULTISPAN TC-442 quick start guide

MULTISPAN

MULTISPAN TC-442 quick start guide

YOKOGAWA Green Series user manual

YOKOGAWA

YOKOGAWA Green Series user manual

Auber Instruments WS Series Operation & instruction manual

Auber Instruments

Auber Instruments WS Series Operation & instruction manual

oventrop Unibox E BV vario operating instructions

oventrop

oventrop Unibox E BV vario operating instructions

Dometic Frigo DC Service manual

Dometic

Dometic Frigo DC Service manual

Eurotherm 2116 user guide

Eurotherm

Eurotherm 2116 user guide

Boldrin Group Como Operating and installation instructions

Boldrin Group

Boldrin Group Como Operating and installation instructions

DeDietrich AD251 Assembly instructions

DeDietrich

DeDietrich AD251 Assembly instructions

DAVIS 6830 user manual

DAVIS

DAVIS 6830 user manual

Penn A421ABT series installation instructions

Penn

Penn A421ABT series installation instructions

gefran 650 Series Abbreviated Manual

gefran

gefran 650 Series Abbreviated Manual

Viessmann VITOSOLIC 200 operating instructions

Viessmann

Viessmann VITOSOLIC 200 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.