www.zamel.com
LCD screen
CARBON MONOXIDE DETECTOR
Battery-operated
CTW-03
User Manual
inside
Tested in Poland
– Certicate
of Performance
ZAMEL Sp. z o.o., 43-200 Pszczyna, ul. Zielona 27, tel.: 32 210 46 65; fax: 32 210 80 04
e-mail: [email protected], www.zamel.com
Carbon monoxide (CO) is a highly toxic, colourless and odourless gas that easily spreads in the air. Carbon
monoxide is a product of incomplete combustion of certain fuel types, including: wood, furnace oil, earth gas,
petrol, kerosene, propane gas, coal, or petroleum. Carbon monoxide is colourless and odourless; it is then
critical to provide early detection and warning of hazardous CO concentration in inhabited rooms.
FEATURES:
• Tested in Poland in a dedicated test chamber: features an additional Certicate of Performance in 300
ppm detection in less than 3 minutes of exposure
• Carbon monoxide detection levels (ref. standard: PN-EN50291-1:2010+A1:2012: 50 ppm (in up to 90
minutes); 100 ppm (in up to 40 minutes); 300 ppm (in up to 3 minutes)
• Electrochemical sensor (10 years of service life)
• LCD with actual CO
concentration readings
and user messages
• Battery-operated
• Low battery indicator
• Detector failure indicator
(self-diagnostic system)
• Past CO detection
event memory
Power supply: 3 x 1.5 V batteries, type AA; IP20
Net weight:: 0,13 kg
Country of origin: PRC
Manufactured for: Zamel Sp. z o.o. by: NDE Ltd.
The Declaration of Conformity is available at www.zamel.com
Do not dispose of this device with other waste! In order to
avoid harmful effects on the environment and human health,
the used device should be stored in designated areas. For
this purpose, you can dispose of household waste free of
charge and in any quantity to a collection point set up, as
well as to the shop when you buy new equipment.
plik: CTW-03_GB | modykacja: 16.04.2020
It is recommended that the device is installed by
a qualied individual
The present device has been designed to protect
people against severe outcomes of exposure
to carbon oxide. However, it is not able to fully
protect persons with special health problems. If
in doubt, consult a physician.
Read the User Manual inside the packaging
before installing the detector.
Keep the product in a dry place away from
sunlight. Protect
the detector
from damage in
transport and
while handling;
damage may
reduce the service
life.
Do not use the
detector if any
damage is evident.
CTW-03
CARBON MONOXIDE DETECTOR
10 years
of sensor
service life
Tested in Poland
– Certicate
of Performance
CTW-03_GB.indd 2-3
CTW-03_GB.indd 2-3
16.04.2020 07:41
16.04.2020 07:41
SPECIFICATIONS
• Power supply: 3 x 1.5 V batteries, type: AA
• Sensor design: electrochemical (approx. 10 years of service life)
• Stand-by input current: 35 uA
• Alarm mode input current: 85 mA
• Sound level: 85 dB
• Light alarm indication
• LCD with CO concentration readings and message output
• Carbon monoxide detection levels (ref. standard: PN-EN 50291-1:2010+A1:2012):
- 50 ppm (in up to 90 minutes)
- 100 ppm (in up to 40 minutes)
- 300 ppm (in up to 3 minutes)
• Additional Test Certicate for CO Detection Sensitivity
(300 ppm detected in less than 3 min), tested in a dedicated test chamber
• Ingress protection rating: IP 20
• Operating temperature: 0°C to +45°C
• Operating humidity: 0 to 90% RH
• Dimensions: 140 × 65 × 27 mm
1. INSTALLATION
• It is recommended that the device is installed by a qualied individual.
• Keep the product in a dry place away from sunlight. Protect the detector from damage in transport and while handling; damage may
reduce the service life. Do not use the detector if any damage is evident. It is recommended to have the product installed by a qualied
professional.
• Install the detector near locations extremely exposed to carbon monoxide concentrations developing from combustion of fuel, e.g. earth
gas, wood, or coal. To prevent false detection alarms, install the CO detector at least 2 m from all potential carbon monoxide emission
sources.
• Install the CO detector approx. 150 cm above the oor.
• To ensure optimum protection against CO hazards, install CO detectors in all rooms of prolonged inhabitation, especially bedrooms. Install
at least one CO detector per storey in multistorey buildings.
• Do not install CO detectors in ‘dead spaces’ (e.g. in recesses closed off by pieces of furniture or curtains, underneath the roof gable, etc.)
and wherever the detection performance will be reduced by currents of fresh air (e.g. near doors, windows, ventilation diffusers or air
fans). Do not install CO detectors in locations highly exposed to airborne dust, aerosols or household chemical which may cause irrepara-
ble failure of the detector.
Warranty Certicate
Reseller’s stamp and signature with date
Reseller’s stamp and signature with date
24-month commercial warranty granted by
ZAMEL Sp. z o.o.
1. ZAMEL Sp. z o.o. grants a 24-month warranty for the products it sells.
2. The warranty granted by ZAMEL Sp. z o.o. does not cover:
a) defects caused by transport, handling or other factors;
b) defects caused by improper installation or operation of the products manufactured ZAMEL Sp. z o.o.;
c) defectscausedbyanymodicationsoralterationsmadebytheBUYERoranythirdpartytothesoldproductsortothe
equipment required for the proper operation of the sold products;
d) defects caused by any force majeure event or another fortuitous event beyond any reasonable control of ZAMEL Sp. z o.o.
e) the power supply (batteries) included (if any) with the product as sold.
3. TheBUYERshallsubmitallwarrantyclaimsinwritingtotheoriginalresellerortoZAMELSp.zo.o.
4. ZAMEL Sp. z o.o. will examine each warranty claim as regulated by the applicable provisions of the Polish law.
5. If found valid by examination, the warranty claim will be processed by replacement of the defective product, its repair or a refund
of the price of purchase at the sole discretion of ZAMEL Sp. z o.o.
6. Thiswarrantyisonlyeffectiveonthefollowingterritories:RepublicofPoland.
7. NorightsoftheBUYERarisingfromthestatutoryorregulatorylawsconcerningimpliedwarrantyfordefectsofsoldgoodsare
limited, prejudiced or excluded by this warranty.
While an installed CO detector greatly improves indoor habitation safety, they are not 100% reliable in CO detection due
to the risks of detector failure, battery depletion and ambient effects. It is critical to periodically test the performance of
CO detectors (which is specied in this User Manual) and home heating equipment (including stoves, heaters, etc.) and
inspect all ventilation and ue gas exhaust systems for obstruction in the rooms monitored by CO detectors to minimise CO
concentrations that are hazardous to health and life.
Read the User Manual inside the packaging before installing the detector.
CTW-03_GB.indd 4-5
CTW-03_GB.indd 4-5
16.04.2020 07:41
16.04.2020 07:41

Popular Gas Detector manuals by other brands

BW Technologies GasAlertMicro 5 user manual

BW Technologies

BW Technologies GasAlertMicro 5 user manual

CGS Merlin 1500S Installation & operation manual

CGS

CGS Merlin 1500S Installation & operation manual

TLV SonicMan SO2 instruction manual

TLV

TLV SonicMan SO2 instruction manual

RKI Instruments 65-2428 Operator's manual

RKI Instruments

RKI Instruments 65-2428 Operator's manual

Evikon E2648 Series user manual

Evikon

Evikon E2648 Series user manual

LEGRAND Galea Life 7756 78 manual

LEGRAND

LEGRAND Galea Life 7756 78 manual

GTE ADICOS GSME-M4 operating manual

GTE

GTE ADICOS GSME-M4 operating manual

olympia electronics BS-658 quick start guide

olympia electronics

olympia electronics BS-658 quick start guide

UEi CD100A-N instruction manual

UEi

UEi CD100A-N instruction manual

SISCO GD300:XX instruction manual

SISCO

SISCO GD300:XX instruction manual

Elektrotechnik Schabus GX-B3 operating instructions

Elektrotechnik Schabus

Elektrotechnik Schabus GX-B3 operating instructions

Oldham OLC 100 user manual

Oldham

Oldham OLC 100 user manual

DALEMANS DAT 420 Calibration manual

DALEMANS

DALEMANS DAT 420 Calibration manual

Critical Environment Technologies CGAS-AP installation manual

Critical Environment Technologies

Critical Environment Technologies CGAS-AP installation manual

Blackline Safety G7 BRIDGE Guide

Blackline Safety

Blackline Safety G7 BRIDGE Guide

Tecnocontrol TS292P user manual

Tecnocontrol

Tecnocontrol TS292P user manual

seeed studio Grove MQ3 manual

seeed studio

seeed studio Grove MQ3 manual

Master cool Intella Sense III operating instructions

Master cool

Master cool Intella Sense III operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.