Zephyr Tempest II AK7500ASX Installation guide

Other manuals for Tempest II AK7500ASX

2

This manual suits for next models

2

Other Zephyr Ventilation Hood manuals

Zephyr Typhoon AK2100BS Installation guide

Zephyr

Zephyr Typhoon AK2100BS Installation guide

Zephyr Breeze II Installation guide

Zephyr

Zephyr Breeze II Installation guide

Zephyr AK6500 series Use Installation guide

Zephyr

Zephyr AK6500 series Use Installation guide

Zephyr Venezia Installation guide

Zephyr

Zephyr Venezia Installation guide

Zephyr AK7000AS Installation guide

Zephyr

Zephyr AK7000AS Installation guide

Zephyr SAVONA ZSA-M90AS Installation guide

Zephyr

Zephyr SAVONA ZSA-M90AS Installation guide

Zephyr ATI-M90ASX User manual

Zephyr

Zephyr ATI-M90ASX User manual

Zephyr Okeanito COK-E36SX Installation guide

Zephyr

Zephyr Okeanito COK-E36SX Installation guide

Zephyr Cypress AK7848ASX Installation guide

Zephyr

Zephyr Cypress AK7848ASX Installation guide

Zephyr Typhoon AK2100 Installation guide

Zephyr

Zephyr Typhoon AK2100 Installation guide

Zephyr ZPY-E30 (B Installation guide

Zephyr

Zephyr ZPY-E30 (B Installation guide

Zephyr Trapeze CTP-E 48SX User manual

Zephyr

Zephyr Trapeze CTP-E 48SX User manual

Zephyr AK2100AS Installation guide

Zephyr

Zephyr AK2100AS Installation guide

Zephyr Siena Pro Island ZSL-E42AS Installation guide

Zephyr

Zephyr Siena Pro Island ZSL-E42AS Installation guide

Zephyr Genova Series User manual

Zephyr

Zephyr Genova Series User manual

Zephyr Roma Groove ZRG-E30BS Installation guide

Zephyr

Zephyr Roma Groove ZRG-E30BS Installation guide

Zephyr Tornado II AK8200AS Installation guide

Zephyr

Zephyr Tornado II AK8200AS Installation guide

Zephyr ZML-M90S/G Installation guide

Zephyr

Zephyr ZML-M90S/G Installation guide

Zephyr Angolo ZAG-E30AG Installation guide

Zephyr

Zephyr Angolo ZAG-E30AG Installation guide

Zephyr Verona ZVO-E30BG Installation guide

Zephyr

Zephyr Verona ZVO-E30BG Installation guide

Zephyr Brisas BMI-E36AG Installation guide

Zephyr

Zephyr Brisas BMI-E36AG Installation guide

Zephyr Ombra Installation guide

Zephyr

Zephyr Ombra Installation guide

Zephyr Verona ZVO-M90AG Installation guide

Zephyr

Zephyr Verona ZVO-M90AG Installation guide

Zephyr Firenze ZFI-M90BS Installation guide

Zephyr

Zephyr Firenze ZFI-M90BS Installation guide

Popular Ventilation Hood manuals by other brands

Haier CXW-219-D67 null

Haier

Haier CXW-219-D67 null

emmeti RECUPA MED A-140 Installation and use manual

emmeti

emmeti RECUPA MED A-140 Installation and use manual

Nibe F135 user manual

Nibe

Nibe F135 user manual

Kuppersberg INTRO 60 Technical Passport

Kuppersberg

Kuppersberg INTRO 60 Technical Passport

Hisense MH6INBG manual

Hisense

Hisense MH6INBG manual

Miele DA 1255 Operating and installation instructions

Miele

Miele DA 1255 Operating and installation instructions

Broan 46000 Specification sheet

Broan

Broan 46000 Specification sheet

GE Profile PV977 Owner's Manual & Installation Instructions

GE

GE Profile PV977 Owner's Manual & Installation Instructions

FALMEC FFRIA24W5FS Instruction booklet

FALMEC

FALMEC FFRIA24W5FS Instruction booklet

Whirlpool RH2600XL-1 SERIES installation instructions

Whirlpool

Whirlpool RH2600XL-1 SERIES installation instructions

ETNA AV360RVS Instructions for use

ETNA

ETNA AV360RVS Instructions for use

JUNO JDF603E6 installation manual

JUNO

JUNO JDF603E6 installation manual

Miele DA 6708 D Operating and installation instructions

Miele

Miele DA 6708 D Operating and installation instructions

Tricity Bendix LE 150 Installation & operating instructions

Tricity Bendix

Tricity Bendix LE 150 Installation & operating instructions

AEG X68163BV1 user manual

AEG

AEG X68163BV1 user manual

AEG 125 D operating instructions

AEG

AEG 125 D operating instructions

Smeg KSEV97X instruction manual

Smeg

Smeg KSEV97X instruction manual

Nibe S Series Installer manual

Nibe

Nibe S Series Installer manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
MAY12.0501 © 2012 Zephyr Corporation
Tempest II
AK7500ASX
AK7536ASX
AK7548ASX
READ AND SAVE THESE INSTRUCTIONS
www.zephyronline.com
1
SAFETY NOTICE ................................................................. 2-3
LIST OF MATERIALS....................................................... 4
INSTALLATION
Ducting Calculation Sheet....................................... 5
Mounting Height & Clearance................................ 6
Ducting Options ........................................................... 7
Specifications ............................................................... 8
Electrical ......................................................................... 9
Mounting the Range Hood...................................... 10
CBIxxxB and PBI-1100A Internal Blowers........ 11
CBI-xxxB Horizontal Ducting Conversion......... 12-13
Remote Blower Preparation ................................... 14
FEATURES & CONTROLS
Touch Controls & Features ..................................... 15-16
MAINTENANCE
Cleaning and Filter Removal.................................. 17
Lights................................................................................ 18
TROUBLESHOOTING................................................................ 19
LIST OF PARTS AND ACCESSORIES .............................. 20
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
www.zephyronline.com
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
b. Always turn hood ON when cooking at high heat or when flaming food
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
e. Keep fan, filters and grease laden surfaces clean.
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards.
Including fire-rated construction.
b. Sufficient air is needed for power combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. NEVER place a switch where it can be reached from a tub or shower.
f. Make sure the power is off before installing, wiring or maintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.
OPERATION
Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
- To contact a qualified electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase
and install appropriate connector if necessary.
List of Materials
4
www.zephyronline.com
MODELS: AK7500ASX, AK7536ASX, AK7548ASX
PARTS SUPPLIED
1 - Hood
2 - Baffle filters AK7500ASX, 3 - AK7536ASX, 4 - AK7548ASX
2 - Halogen light bulbs 3 - AK7548ASX (pre-installed)
1 - 10” round transition adapter (for dual internal and external blowers)
1 - External blower wiring (for external blower)
1 - Rectangular starting collar (for single blower horizontal ducting)
1 - 6” round to rectangular transition (for single blower horizontal ducting)
2 - Blower brackets (for single blower horizontal ducting)
1 - Hardware package
HARDWARE PACKAGE CONTENTS
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Single Internal Blower Kits (CBI-290A / CBI-600A)
- Dual Internal Blower Kit (PBI-1100)
- External Blower Kit (CBE-1000)
- In-Line Blower Kit (PBN-1000A)
- Heat Lamp Accessory
- Back Splash Accessory
- Duct Cover Accessory
Light Bulb Removal
Suction Cup (1)
M4 x 1” (4)
M4 x 1-1/2” (4)
M4 x 2” (4)
M4 x 8 (8)
10 x 3/16” (6
M4 x 16 (4)
)
M3.5 x 8 (7)
Wire Caps (3)
- Wood Board to hang hood ( W x D x H)
AK7500ASX - 28” x 3/4” x 4”
AK7536ASX - 34” x 3/4” x 4”
AK7548ASX - 46” x 3/4” x 4”
5
Installation – Ducting Calculation Sheet
Duct pieces To t a l
Equivalent number
length x used =
3-1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
7”-10” Round,
straight
1 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.900
elbow
15 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.450
elbow
9 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.900
flat elbow
24 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
900elbow
20 Ft. x ( ) = Ft.
6” Round,
900elbow
15 Ft. x ( ) = Ft.
6” Round,
450elbow
9 Ft. x ( ) = Ft.
Ft.
6” Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column 1 =
Duct pieces To t a l
Equivalent number
length x used =
6” Round
wall cap
with damper
30 Ft. x ( ) = Ft.
Round
wall cap
with damper
30 Ft. x ( ) = Ft.
7” - 10”
Round,
900elbow
15 Ft. x ( ) = Ft.
7” - 10”
7” - 10”
Round,
450elbow
9 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6” Round,
roof cap
30 Ft. x ( ) = Ft.
7” - 10”
Round,
roof cap
30 Ft. x ( ) = Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
6” round to
3-1/ 4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” round to
3-1/ 4” x 10”
rect.
transition
900elbow
16 Ft. x ( ) = Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” round to
3-1/ 4” x 10”
rect.
transition
900elbow
23 Ft. x ( ) = Ft.
Maximum Duct Length: For satisfactory air movement,
the total duct length should not exceed 100 equivalent feet.
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 6” round or 3-1/4” x 10” rectangular
duct must be used to maintain maximum air flow
efficiency for single internal blower and 10” round
duct for dual internal and remote blower.
Always use rigid type metal ducts only. Flexible
ducts could restrict air flow by up to 50%.
Also use calculation (on page 5) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fire hazard; while hoods
mounted too high will be hard to reach and will
lose its performance and efficiency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Vertical Ducting:
6” round minimum (CBI-xxxB blower)
10” round minimum (PBI-1100A and remote
blowers)
Horizontal Ducting:
3-1/4”x10” minimum (CBI-xxxB blower)
No horizontal option available for PBI-1100A or
remote blower
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
installation.
• If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
• If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
• If the unit is damaged by the installer (if other
than the customer), repair of replacement must
be made by arrangement between customer
and installer.
36”
26” min.
36” max.
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
Some Ducting Options
Installation – Ducting Options
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
Rear Ducting
Side wall cap
w/ gravity damper
External Blower
8
www.zephyronline.com
Installation – Specifications
29 15/16”(30”)
35 15/16” (36”)
47 15/16”(48”)
24” (30”)
30” (36”)
42” (48”)
12”
*10 ”
24”
4”
18”
1 3/8”
9 15/16”
2 3/4”2 3/16”
1 1/8”
8 9/16”
13 3/16”
2 5/16”
6 7/16”
2”
2 1/16”
CL
5 9/16”
ext
blwr
k/o
elec
k/o
2 11/16”
3 7/16”
1 3/16”
elec
k/o
CL
top side
back
4 5/16”
*10” transition used with dual and
external blowers.
22 5/16”
ø 9 15/16”
14
3/16”
10 3/8”
12 3/8”
4 1/4”