Zephyr Venezia ZVE-E30AS Installation guide

Other manuals for Venezia ZVE-E30AS

1

This manual suits for next models

2

Other Zephyr Ventilation Hood manuals

Zephyr ZML-M90BG Installation guide

Zephyr

Zephyr ZML-M90BG Installation guide

Zephyr AK6500 Installation guide

Zephyr

Zephyr AK6500 Installation guide

Zephyr Tidal I Installation guide

Zephyr

Zephyr Tidal I Installation guide

Zephyr Duo Wall ADU - M90ASX User manual

Zephyr

Zephyr Duo Wall ADU - M90ASX User manual

Zephyr Anzio Island Installation guide

Zephyr

Zephyr Anzio Island Installation guide

Zephyr ZMD-E42AS Installation guide

Zephyr

Zephyr ZMD-E42AS Installation guide

Zephyr AK9234AS Installation guide

Zephyr

Zephyr AK9234AS Installation guide

Zephyr CACHE CCA-E30ASX Use Installation guide

Zephyr

Zephyr CACHE CCA-E30ASX Use Installation guide

Zephyr ZPY-E30AS Installation guide

Zephyr

Zephyr ZPY-E30AS Installation guide

Zephyr Bogart EBO-E42ASX Installation guide

Zephyr

Zephyr Bogart EBO-E42ASX Installation guide

Zephyr Venezia ZVE-E30BS Installation guide

Zephyr

Zephyr Venezia ZVE-E30BS Installation guide

Zephyr Luce ZLU-E30BS Installation guide

Zephyr

Zephyr Luce ZLU-E30BS Installation guide

Zephyr AK9028AS Installation guide

Zephyr

Zephyr AK9028AS Installation guide

Zephyr Titan AK7636AS Installation guide

Zephyr

Zephyr Titan AK7636AS Installation guide

Zephyr Pisa ZPI-E24AG Installation guide

Zephyr

Zephyr Pisa ZPI-E24AG Installation guide

Zephyr Titan AK7754BS Installation guide

Zephyr

Zephyr Titan AK7754BS Installation guide

Zephyr Essentials ZAN-E30CS Installation guide

Zephyr

Zephyr Essentials ZAN-E30CS Installation guide

Zephyr AK11005 Installation guide

Zephyr

Zephyr AK11005 Installation guide

Zephyr Pyramid Installation guide

Zephyr

Zephyr Pyramid Installation guide

Zephyr Monsoon Mini II Installation guide

Zephyr

Zephyr Monsoon Mini II Installation guide

Zephyr ARC AHZ-M90AWX User manual

Zephyr

Zephyr ARC AHZ-M90AWX User manual

Zephyr AIN-M80AWX Quick start guide

Zephyr

Zephyr AIN-M80AWX Quick start guide

Zephyr AK6536 Installation guide

Zephyr

Zephyr AK6536 Installation guide

Zephyr Monsoon Mini Installation guide

Zephyr

Zephyr Monsoon Mini Installation guide

Popular Ventilation Hood manuals by other brands

Gorenje S3 IHGC963S4X manual

Gorenje

Gorenje S3 IHGC963S4X manual

KOBE ISX2136SQB-1 Installation instructions and operation manual

KOBE

KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products ADVANTAGE-100H Information & operating instructions

U.S. Products

U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg DUDL 4 LX Technical Passport

Kuppersberg

Kuppersberg DUDL 4 LX Technical Passport

Framtid HW280 manual

Framtid

Framtid HW280 manual

Thermador HGEW 36 FS installation manual

Thermador

Thermador HGEW 36 FS installation manual

Electrolux LFT769X user manual

Electrolux

Electrolux LFT769X user manual

AEG X69453MVO UK user manual

AEG

AEG X69453MVO UK user manual

Broan B5836SS manual

Broan

Broan B5836SS manual

Heinner HDCH-6060RGBK quick start guide

Heinner

Heinner HDCH-6060RGBK quick start guide

Baumatic AS35SS instruction manual

Baumatic

Baumatic AS35SS instruction manual

Franke FTF 604 XS V2 Instructions for use and installation

Franke

Franke FTF 604 XS V2 Instructions for use and installation

Best UCB3I30SBW installation instructions

Best

Best UCB3I30SBW installation instructions

Gram EFU 503-90 X instruction manual

Gram

Gram EFU 503-90 X instruction manual

CIARRA CBCS6803 Installation and user manual

CIARRA

CIARRA CBCS6803 Installation and user manual

sauter SHG501 Instructions for installation and use

sauter

sauter SHG501 Instructions for installation and use

Franke 392-17 User instructions

Franke

Franke 392-17 User instructions

FALMEC Polar Black 35 Instruction booklet

FALMEC

FALMEC Polar Black 35 Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
JUL08.0201 © Zephyr Corporation
Venezia
ZVE-E30AS
ZVE-E36AS
ZVE-E42AS
www.zephyronline.com
1
SAFETY NOTICE................................................................. 2-3
LIST OF MATERIALS....................................................... 4
INSTALLATION
Ducting Calculation Sheet....................................... 5
Mounting Height & Clearance................................ 6
Ducting Options ........................................................... 7
Hood Speci cations ................................................... 8
Mounting the Range Hood...................................... 9
Ductless Recirculating .............................................. 10
FEATURES & CONTROLS
Touch Controls ............................................................. 11
Charcoal Filter Replace Reminder ...................... 12
Metal Mesh Filter Clean Reminder...................... 13
MAINTENANCE
Cleaning and Metal Mesh Filter Care................. 14
Lights................................................................................ 15
TROUBLESHOOTING................................................................ 16
LIST OF PARTS AND ACCESSORIES.............................. 17
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
www.zephyronline.com
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
b. Always turn hood ON when cooking at high heat or when aming food
c. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or lter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
e. Keep fan, lters and grease laden surfaces clean.
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close- tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Installation work and electrical wiring must be done by quali ed person(s) in accordance with all applicable codes and standards.
Including re-rated construction.
b. Suf cient air is needed for power combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFI
(Ground Fault Interrupter protected branch circuit).
g. NEVER place a switch where it can be reached from a tub or shower.
h. Make sure the power is off before installing, wiring or maintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
To reduce risk of re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,
attics, crawl spaces or garages.
OPERATION
Always leave safety grilles and lters in place. Without these components, operating blowers could catch onto hair, ngers
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
*NOTE: Please check www.zephyronline.com for revisions before doing any custom work.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
- To contact a quali ed electrical installer.
- To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a quali ed electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a quali ed electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes. Check with local requirements, purchase
and install appropriate connector if necessary.
ZVE-E30AS - 420 Watts, 3.5 Amps
ZVE-E36AS - 520 Watts, 4.3 Amps
ZVE-E42AS - 520 Watts, 4.3 Amps
List of Materials
4
www.zephyronline.com
Wire Nuts (3)
M4 x 1-1/4” (3) M4 x 1” (2)
M4 x 3/8” (2)
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
- Cable connector (if required by local codes)
- Back splash accessory
- Wire spice rack accessory
- Duct cover extension accessory
- Recirculating kit accessory
HARDWARE PACKAGE CONTENTS
MODELS: ZVE-ExxAS
PARTS SUPPLIED
1 - Hood with internal blower
3- Metal mesh filters (2 for ZVE-E30AS)
1 - Duct cover assembly (top and bottom)
1 - Duct cover wall bracket
4 - 50W GU-10 halogen light bulbs (2 for ZVE-E30AS)
1 - 6” round backdraft damper (pre-installed)
1 - Hardware package
Suction Cup (1)
5
Duct pieces To t a l
Equivalent number
length x used =
3-1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
8” Round,
straight
1 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.900
elbow
15 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.450
elbow
9 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.900
flat elbow
24 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
900 elbow
20 Ft. x ( ) = Ft.
6” Round,
900 elbow
15 Ft. x ( ) = Ft.
6” Round,
450 elbow
9 Ft. x ( ) = Ft.
Ft.
7” Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column 1 =
Duct pieces To t a l
Equivalent number
length x used =
6”- 8”Round
wall cap
with damper
30 Ft. x ( ) = Ft.
Round
wall cap
with damper
30 Ft. x ( ) = Ft.
7” or 8”
Round,
900elbow
15 Ft. x ( ) = Ft.
7” or 8”
7” or 8”
Round,
450
elbow
9 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6”- 8” Round,
roof cap
30 Ft. x ( ) = Ft.
7” or 8”
Round,
roof cap
30 Ft. x ( ) = Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
Maximum Duct Length: For satisfactory air movement,
the total duct length of a 3 1/ 4” x 10” rectangular 6” or 7”
diameter round duct should not exceed 100 equivalent feet.
6” round to
3-1/ 4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” round to
3-1/ 4” x 10”
rect.
transition
900 elbow
16 Ft. x ( ) = Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” round to
3-1/ 4” x 10”
rect.
transition
900 elbow
23 Ft. x ( ) = Ft.
Installation – Ducting Calculation Sheet
Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 6” round or 3-1/4 x 10” rectangular
duct must be used to maintain maximum air ow
ef ciency.
Always use rigid type metal ducts only. Flexible
ducts could restrict air ow by up to 50%.
Use calculation worksheet to compute total duct
work.
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far
away from opening and as far apart, between 2,
as possible.
Minimum mount height between range top to hood
bottom should be no less than 28”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and re hazard; while hoods
mounted too high will be hard to reach and will
loose its performance and ef ciency.
If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
Minimum Mounting Height (Ducted)
8’. Hood mounted 28” above cooking surface;
64” from oor.
Minimum Mounting Height (Recirculating)
8’4”. Hood mounted 28” above cooking surface;
64” from oor.
Maxmimum Mounting Height
10’3”. Hood mounted 36” above cooking surface;
72” from oor.
Duct cover extension kit available for ceiling
heights up to 14 feet. Turn to page 17 for part
number and ordering information.
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
installation.
• If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
• If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
• If the unit is damaged by the installer (if other
than the customer), repair of replacement must
be made by arrangement between customer
and installer.
min. ducted 32-1/2”
min. recirc. 36“
max. 51”
min. 28”
max. 36”
36”
Note: Top duct cover with louver holes may be flipped upside down to hide louvers.
min. ducted 96”
min. recirc. 100”
max. 123”
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside, unless using the recirculating option.
Use single wall rigid Metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certi ed Silver Tape or Duct Tape.
Some Ducting Options
Installation – Ducting Options
side wall cap
w/ gravity damper
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
ductless
recirculating
side wall cap
w/ gravity damper
8
www.zephyronline.com
Installation – Hood Specifications
Top of Hood
Side of HoodFront of Hood
ø5 7/8”
14-5/16”10-5/8”
21-1/4”10”
min. ducted 32-1/2””
min. recirc. 36”
max. 51”
24”
29-15/16”, 35-15/16”, 41-15/16”
1-5/8”
4”
1-1/4”
2”
electrical
k/o