Push buttons
introduction
1. Power switch button: press button and hold for 2 seconds to turn on or off the
power of ZGFreeBox;
ZGFreeBox label
information
1. ZGFreeBox label information is as below
ZG FreeBox Packing List
Packing List
1. ZGFreeBox and data cable 2. Wireless router and network cable

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
ZG FreeBox Instructions
Wireless router connect
to main power
1. Connect wireless router to main power: The indicator light on the router shows
white light, to be noticed, the input voltage should be 220V,
Router working status
Computer connect to
router
1. Connect one end of the network cable to any socket under the "LAN1, LAN2,
LAN3" label of the router, and connect the other end to the computer's network
port
Router connect network cable
Computer connection network cable

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
Connect data cable to
ZGFreeBox
①Input Voltage:25.2V
②USB Port
1. Connect the data cable to the ZGFreeBox as below. To be notice, the power data
cable plug and the ZGFreeBox power data socket have red dots, please insert them
correctly and completely. Confirm that the double red dots are on the same
line.
Power connection
USB cable connection
Data cable connected to
the scanner
1. Connect the data cable power plug and the data cable plug to the corresponding
jack of the scanner

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
data cable connect to scanner
Turn on the ZGFreeBox
1. Press power button hold for 2 seconds to turn on ZG FreeBox;
ZG FreeBox working status
Power Display
1. Turn on the ZGFreeBox, the display will light up and displaying real-time battery
information, etc.
To be notice, the full power voltage will be 25V, when power below 20V is
required to recharge device.
Software connection
1. Open the scanning software and click the "Option" button in the upper right
corner;

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
2. Click the “Wireless Version” in the “option” interface, , and change the
corresponding IP address in the software according to the IP information of the
ZGFree Box label or router label;
3. After the operation is completed, wait for about 40S, then the software will
change the corresponding
IP address in the software
according to the IP
address on the label.

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
connect to the ZGFree Box successfully. The function keys of the software will
light up normally;
4.Display will showing “Ready” once connection successed.
Software function
1. Please check RigelScan Elite unser manual
Turn off ZG FreeBox
1. After the scanning process is completed, please turn off the ZGFree Box in time
and save the power. Press and hold the "power switch button" for 3 second to turn
off it.
2. Put the ZGFree Box, router and accessories in order according to the intervals in
the equipment box, and keep them well.

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
ZGFree Box charging instructions
ZGFree Box charging
1. Connect the power adapter to ZG FreeBox, the indicator light of the power adapter
shows green. Afterwards, connect power adapter to main power, and the indicator
light of the power adapter turn to red and charging is start. When the indicator
light turns to green, it indicates that the ZGFree Box is fully charged.
ZG FreeBox II Trouble shooting
Network connectivity
1. Press the "Windows" + "R" keys at the same time to run the data "cmd" on the
interface;

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
2. In the code running interface, enter "ping-blank-IP address", the IP address should
be the same as the ZGFree Box label or router label, and should be same as the
ZGFreeBox IP address in the software;
3. Connection is normal as shown below,
4. Connection is abnormal as shown below,

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
IP address check
1. Checking to make sure the IP address in the software is identical and consistent
with the address on the ZGFree Box label and router label;
Software function check
1. Please replace the instrument and device files, restart the ZGFree Box, unplug all
relevant data cables and power sockets, then restart the software;
2. If you encounter the following situations when scanning the surface or point cloud
in the software,
1)The number of frames no longer increases, and the software interface still
exists;
2)The laser line disappears and the software interface is stuck;
3)After long time scanning, the software may crash with probability;
Please restart the ZGFree Box, unplug all relevant data cables and power sockets,
then restart the software;
Scanning Precautions
1. The data transmission of ZGFree Box is based on the signal transmission of the
router, please keep the router and the ZGFree Box free of obstacles or signal
interference;
2. In order to maintain the stability of data transmission, please use a network cable
to connect the router and the computer, do not unplug the network cable port;
3. During the scanning process, please do not disconnect the power adapter of the
router or computer at will to terminate the power input;
4. During the scanning process, do not turn off the power of the ZGFree Box to avoid
interruption of data transmission;
5. The 5G WIFI of the wireless router is susceptible to interference from external
electromagnetic signals, please do not use two or more 5G routers at the same
time;
6. It’s normal situation if the wireless transmission speed is a bit slow, the number of
real-time scanning frames is slightly lower and the laser line flickers.
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any inte rference received, including interference that may
cause undesired operation.

ZG TECHNOLOGY CO., LTD.
BLD A17-3, NO.555, WenHua Ave, Hongshan District , Wuhan, China
Tel: +0086 27 8774 1893 Web: www.zg-3d.com
CO., LTD.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interferenceto radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure
Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.