Zipato PSE02 User manual

Multiple Sound Siren PSE02
The multiple sound siren PSE02 is a wireless siren, based on Z-WaveTM
technolog . It is the Z-WaveTM plus product, it support the securit ,
OTA... Those newest features of the Z-WaveTM technolog . Z-WaveTM is a
wireless communication protocol designed for home automation,
specificall to remotel control applications in residential and light
commercial environments. The technolog uses a low-power RF radio
embedded or retrofitted into home electronics devices and s stems,
such as lighting, home access control, entertainment s stems and
household appliances.
This product can be included and operated in an Z-WaveTM network
with other Z-WaveTM certified devices from other manufacturers and/or
other applications. All non-batter operated nodes within the network
will act as repeaters regardless of vendor to increase reliabilit of the
network.
The device adopt the Z-WaveTM 500 series chip, when our Z-WaveTM
network s stem is all made b Z-WaveTM 500 series devices. The
network s stem will have the advantages as below.
•Concurrent multi-channel support reduces external interference.
•Better RF range, improve about 10 meters in indoor.
•Support 100 Kbps transmit speed, speed up communication.
Product Overview
Adding to Z-WaveTM Network
There are one tamper ke and a circle button behind the device. Both
of them can add, remove, reset or association from Z-WaveTM network.
In the first time, add the device into the Z-WaveTM network. First, make
sure the primar controller is in the add mode. And then power on the
device. The device will auto start the NWI (Network Wide Inclusion)
mode. And it should be included in 5 seconds. You will see the LED
light ON one second.
1
Siren
Tamper Ke
Circle Button
Batter
(Optional)
DC Jack

Notice: Including a node ID allocated b Z-WaveTM Controller means
“Add” or “Inclu ion”. Excluding a node ID allocated b Z-WaveTM
Controller means “Remove” or “Exclu ion”.
Function De cription
Add
1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing tamper ke three times within 1.5 seconds
to enter the inclusion mode.
3. After add successful, the LED will light ON 1 second
Remove
1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing tamper ke three times within 1.5 seconds
to enter the exclusion mode.
Node ID has been excluded.
Reset
Notice: U e thi procedure only in the event
that the primary controller i lo t or
otherwi e inoperable.
1. Pressing tamper ke four times within 1.5 seconds
and do not release the tamper ke in the 4th
pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that
within 2 seconds, release the tamper ke . If
successful, the LED will light ON one second.
Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to
factor default.
Association
1. Have Z-WaveTM Controller entered association
mode.
2. Pressing tamper ke three times within 1.5 seconds
will enter association mode.
Note: The device support 1 group.
The group 1 is for receiving the report message, like
tamper event. And the group support 8 nodes
maximum.
•Failed or success in including/excluding the node ID can be
viewed from Z-WaveTM Controller.
Notice 1: Alwa s RESET a Z-WaveTM device before tr ing to add it to a
Z-WaveTM network.
Notice 2: When the device into NWI mode, the device functionalit
will useless. The NWI mode will timeout after 3 minutes. You can press
the tamper ke (or the circle button) 3 times to abort the NWI mode.
Z-WaveTM Me age Report
In default the device will using Notification Report to represent the
trigger event, it can be changed to Sensor Binar Report b setting the
configuration NO. 7 Bit4 to 1.
* Tamper Report:
When the tamper ke is pressed over 5 seconds. The device will into
the alarm state. In that state, if the tamper ke be released, the device
will unsolicited to send the report to the nodes in the group 1.
Notification Report (V4)
Notification T pe: Home Securit (0x07)
Event: Tampering. Product covering removed (0x03)
Sensor Binar Report (V2)
Sensor T pe: Tamper (0x08)
Sensor Value: 0xFF
Siren State Report
When the siren start pla ing or stop the alarm sounds, the device will
unsolicited to send the “Sensor Binar Report” to the nodes in the
group 1.
Sensor T pe: General Purpose (0x01)
Sensor Value: 0xFF (Start pla ), or 0x00 (Stop pla )
2

Power Up Procedure
* NWI
When the device power on, the device will check is it alread adding to
the network? If doesn't, it will auto start the NWI mode. The LED will
flash in ever second and continue 3 minutes. Until timeout or the
device successful to inclusion b controller. The use can presses the
tamper ke (or the circle button) 3 times to abort the NWI mode.
Play Sound
Using the SWITCH_BINARY_SET to pla the siren, 0xFF will pla the
emergenc sound, 0x00 will stop to pla .
The device also supports to receive the NOTIFICATION_REPORT to pla
the different sound.
Notification T pe Event Sound
Smoke Alarm (0x01) 0x01 ~ 0xFF Fire Alert
Access Control (0x06) Window/Door
Open (0x16) Door Chime
Home Securit (0x07) 0x01 ~ 0xFF Emergenc
Emergenc Alarm (0x0A) Contact Police
(0x01) Police Car Sound
Emergenc Alarm (0x0A) Contact Fire
Service (0x02) Fire Alert
Emergenc Alarm (0x0A) Contact Medical
Service (0x03) Ambulance Sound
Over The Air (OTA) Firmware Update
The device support the Z-Wave firmware update via OTA.
Before starting the procedure, please remove the back cover of the
device. Otherwise the hardware check will be failed.
Let the controller into the firmware update mode, and then press the
front tamper ke once to start the update.
After finish the firmware download, the LED will start flash in ever 0.5
second. At that time,
plea e don't cut off the power
, otherwise it
will cause the firmware broken, and the device will no function.
After the LED stop flash, it is recommended that the user power up the
device. Caution: After power off the device, please wait about 30
seconds, and then re-plug the power line.
Security Network
The device support the securit function. When the device included
with a securit controller, the device will auto switch to the securit
mode. In the securit mode, the follow commands need using Securit
CC wrapped to communicate, otherwise it will not response.
Note: A “Securit Enabled Z-Wave Controller” must be used in order to
full utilize this function.
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_BASIC
Manual Battery Shutdown
When the DC power is dropped. The s stem will auto switch to use the
batter power. If ou want to reall shutdown the s stem, please follow
instructions as below.
1. Press and hold the circle button.
2. Click the tamper 3 times in 1.5 seconds.
3. Release the circle button.
3

4. If shutdown successful, the LED will flash 3 times.
After the batter shutdown, the s stem won't work an more, unless the
DC power recover .
Z-Wave Configuration Setting
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the setting
still keep, don't reset to factor default. Unless the user execute the
“RESET” procedure.
* The reserve bit or not supported bit is allowed an value, but no effect.
NO. Name Def. Valid Description
7
(*)
Customer
Function
0All Customer function switch, using bit
control.
0Bit0: Reserve.
0Bit1: Reserve.
0Bit2: Reserve.
0Bit3: Reserve.
0
Bit4: Notification T pe,
0: Using Notification Report.
1: Using Sensor Binar Report.
0Bit5: Reserve.
0Bit6: Reserve.
0Bit7: Reserve.
29 Disable Alarm 0 0,1
Disable the alarm function.
1: Disable Alarm, 0: Enable Alarm.
Caution: After the power up, this
configuration alwa s be 0.
31 Alarm Duration 6 0~127
Pla alarm sound duration, 1 tick is 30
seconds. Default is 3 minutes, maximum
is 63.5 minutes
0: means never auto stop.
Z-Wave Supported Command Cla
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_BASIC
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_SECURITY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Specification
Power b DC 5V, and support backup lithium batter (Optional).
Signal (Frequenc ):
868.40 MHz, 869.85 MHz(EU),
908.40 MHz, 916.00 MHz(US),
922~927 MHz(JP/TW),
921.40 MHz, 919.80 MHz(ANZ),
869.00 MHz(RU),
4

865.20 MHz(IN),
916.00 MHz(IL),
Range:
Minimum 40 meters indoor,
100 meters outdoor line of sight.
Operating Temperature: -10oC ~ 40oC
For indoor use onl .
Specifications subject to change without notice due to continuing
product improvement.
FCC ID: RHHPSE02
FCC Interference Statement
This equipment has been tested and found to compl with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequenc energ and, if not installed and used in
accordance with the instructions, ma cause harmful interference to
radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined b turning the equipment off and on, the user is
encouraged to tr to correct the interference b one of the following
measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for
help.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device ma not cause harmful interference, and
(2) This device must accept an interference received, including
interference that ma cause undesired operation.
FCC Caution: An changes or modifications not expressl approved b
the part responsible for compliance could void the user's authorit to
operate this equipment.
This transmitter must not be co-located or operating in conjunction
with an other antenna or transmitter.
Warning
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. Contact our local government for
information regarding the collection s stems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging
our health and well-being.
When replacing old appliances with new once, the retailer is legall
obligated to take back our old appliance for disposal at least for free
of charge.