Ziton ZR4-RL User manual

SERIAL No
PRESS HERE TO
LOG ON
3.5 - 4.5V DC
0.2 - 300mA
1W Max
SERIAL No
PRESS HERE TO
LOG ON
3.5 - 4.5V DC
0.2 - 300mA
1W Max
Wireless RIM Base
EN54-25: 2008
Technical Data refer toInstallation guide
Part No: ZR401-RL
0359-CPR-00424
Ziton Wireless Remote Indicator Installation Guide
General
The Ziton wireless remote indicator and ancillary
equipment are available under the following part
numbers:
PART NO VARIANT TYPE
ZR4-RL Ziton wireless remote indicator
c/w wireless base
ZR401-RL Ziton wireless remote indicator
base (no remote indicator)
ZX4-RL Ziton wireless remote indicator
(no wireless base)
The address of the unit is set when programming the
device to the system (see commissioning manual for
details). The installation must conform to BS5839: Part 1
(or applicable local codes).
Installation of Ziton wireless remote indicator
Ensure that all detectors are sited in accordance with the
survey and design details.
First disengage the remote indicator from the wireless
module by turning it counter clockwise. This exposes the
user features in the wireless module, see Figure 2.
Disengage the mounting plate by pressing down the
locking pin, see Figure 2, and turn the wireless module
counter clockwise whilst pressing it against the
mounting plate.
This dis-assembles the mounting plate from the wireless
module and remote indicator sections, see Figure 1. The
mounting plate is now free to be xed to the wall or
ceiling.
To guarantee correct operation, connect the power
jumper across the PIN header on the wireless module
located under the remote indicator, see Figure 2.
©2015 EMS Security Group Ltd. All rights reserved 1 / 44 / 4 TSD170 Iss 2 27/07/15 AJM©2015 EMS Security Group Ltd. All rights reserved
Figure 1
Ident
Locking mechanism
Power jumper
Figure 2
Notes
TSD170 Iss 2 27/07/15 AJM
Mounting Plate
Wireless Module
Remote Indicator
Fix Mounting Plate
Fix the mounting plate using suitable xings and
fasteners. All four mounting holes must be used, see
Figure 3 for highlighted mounting holes.
When wall mounting, to ensure the text
description of the head is shown correctly, the
mounting plate should be installed in the orientation
shown in Figure 3.
It is important that fastener heads are ush or sub-ush
with the internal surface of the ceiling mount to avoid
the risk of damaging the battery PCB.
!
2 / 4©2015 EMS Security Group Ltd. All rights reserved 3 / 4©2015 EMS Security Group Ltd. All rights reserved
Specication
Operating
Temperature -10 to +50°C
Storage
Temperature -20 to +60°C
Humidity Up to 95% non-condensing
Supply 6x AA Alkaline (Panasonic LR6AD
Powerline / Varta 4006 Industrial)
IP Rating IP32
Operating
Frequencies 868 MHz
Output Transmitter
Power Variable 0-14 dBm
Dimensions 113mm (Ø) 40mm (D)
(No remote indicator)
113mm (Ø) 90mm (D)
(With remote indicator)
Weight 0.30kg (No remote indicator)
0.40kg (With remote indicator)
Regulatory information
Manufacturer EMS Security Group Ltd.
Technology House, Sea Street,
Herne Bay, Kent, CT6 8JZ,
United Kingdom
Year of
manufacture See serial number label inside unit
Certication
Certication body
CPR Certicate 0359-CPR-00424
Approved to EN54-25
Application Indoor use only
European Union
directives EMS Security Group Ltd hereby
declares that this device is in
compliance with the essential
requirements and other relevant
provisions of Directive 2014/53/EU
(R&TTE directive).
2012/19/EU (WEEE directive):
Products marked with this symbol
cannot be disposed of as unsorted
municipal waste in the European
Union. For proper recycling, return
this product to your local supplier
upon purchase of equivalent new
equipment, or dispose of it at
designated collection points. For
more information see
www.recyclethis.info
Contact information
For contact information, see www.utcreandsecurity.com
Mounting
positions
Figure 3
Figure 5
Programming
The Ziton Wireless Remote Indicator requires
programming onto the system.
Please Note: The nal commissioning and hand over of
the wireless re system to the end user is the
responsibility of the re installation contractor.
TSD170 Iss 2 27/07/15 AJM TSD170 Iss 1c 02/09/14 AJM
Battery tment
The Ziton Remote Indicator is powered by 6 x AA alkaline
batteries. These are supplied tted. Should batteries
require replacement, only use specied batteries whilst
observing correct polarity as shown in Figure 4.
Tamper
spring
Figure 4
Device Reassembly
To reassemble the unit, rstly t the remote indicator
section to the wireless module by turning clockwise to
achieve a positive location.
Then the wireless module should be re tted to the
mounting plate by turning it clockwise to achieve a
positive location. Ensure that the tamper switch operates
correctly. The switch should make contact with the
mounting plate.
Device Locking
The device can be locked into its mounting plate by
removing the cut out section as shown in Figure 5 .
To unlock the device, insert a at bladed screwdriver into
the release slot and turn the remote indicator counter
clockwise to release it from the wireless module as shown
in Figure 6.
Figure 6
THIS WAY UP
WHEN WALL
MOUNTING
0359
14

This manual suits for next models

2

Other Ziton Measuring Instrument manuals

Ziton ZP2-ZI Assembly instructions

Ziton

Ziton ZP2-ZI Assembly instructions

Ziton ZP2-ZI Assembly instructions

Ziton

Ziton ZP2-ZI Assembly instructions

Ziton ZP755V Assembly instructions

Ziton

Ziton ZP755V Assembly instructions

Ziton ZR4-RL User manual

Ziton

Ziton ZR4-RL User manual

Popular Measuring Instrument manuals by other brands

SUPMEA SUP-5000C user manual

SUPMEA

SUPMEA SUP-5000C user manual

Siko IMS360 quick start guide

Siko

Siko IMS360 quick start guide

MEWOI MEWOI400 user manual

MEWOI

MEWOI MEWOI400 user manual

Eastron SDM630MCT-RC manual

Eastron

Eastron SDM630MCT-RC manual

Kimo CO 110 user manual

Kimo

Kimo CO 110 user manual

Emerson PENBERTHY LC Series Installation, operation and maintenance instructions

Emerson

Emerson PENBERTHY LC Series Installation, operation and maintenance instructions

KAM Simple Precision CHA user manual

KAM

KAM Simple Precision CHA user manual

National Instruments SC-2345 Carrier user manual

National Instruments

National Instruments SC-2345 Carrier user manual

Knick Stratos Pro A2 Oxy Series quick start guide

Knick

Knick Stratos Pro A2 Oxy Series quick start guide

Hydrotechnik MultiSystem 5070 operating instructions

Hydrotechnik

Hydrotechnik MultiSystem 5070 operating instructions

Scheppach wm 42 quick start guide

Scheppach

Scheppach wm 42 quick start guide

Extech Instruments RF153 user manual

Extech Instruments

Extech Instruments RF153 user manual

Conrad 85 73 36 operating instructions

Conrad

Conrad 85 73 36 operating instructions

TESTO 112 instruction manual

TESTO

TESTO 112 instruction manual

elsner elektronik KNX LW sl 70164 Installation and adjustment

elsner elektronik

elsner elektronik KNX LW sl 70164 Installation and adjustment

Baker Hughes Druck Sensycal DPI800 instruction manual

Baker Hughes

Baker Hughes Druck Sensycal DPI800 instruction manual

Shimpo FGV-0.5XY instruction manual

Shimpo

Shimpo FGV-0.5XY instruction manual

Elis FLONEX FXx11x Series Control Instructions

Elis

Elis FLONEX FXx11x Series Control Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.