ZP700 Series Addressable Detector
Installation Sheet
1
2
3
4
EN: Installation Sheet
Description
ZP700 Series Addressable Detector models are shown in
Table 1.
Table 1: Models
Number Description
ZP720-3P Addressable Thermal Sensor, Polar White
ZP730-2P
ZP730-2B
ZP730-2S30
Addressable Optical Smoke Sensor, Polar White
Addressable Optical Smoke Sensor, Black
Addressable Optical Smoke Sensor, Chubb
ZP732-2P
ZP732-2S30 Combination Smoke and Heat Detector, Polar White
Combination Smoke and Heat Detector, Chubb
Figures
Figure 1: Inserting the detector
Figure 2: Position of the locking tab
Figure 3: Removing a locked detector
Figure 4: Setting the address
Installation
Note: For general guidelines on system planning, design,
installation, commissioning, use and maintenance, refer to the
EN 54-14 standard and local regulations.
To install a detector:
Insert the detector head into the mounting base and rotate it
clockwise until it clicks into place (Figure 1).
The detector may be locked into the mounting base if required.
To do this, remove the locking tab before installation shown in
Figure 2.
www.acornfiresecurity.com
www.acornfiresecurity.com
After installation, ensure that the detector communicates with
the control panel. Always test detectors after installation.
To remove a locked detector:
1. Insert a small screwdriver into the locking tab slot
(Figure 3).
2. Press and rotate the detector anticlockwise.
Setting the address
The detectors include a seven-segment DIP switch (SW1) for
assigning device addresses. Each switch segment has a
decimal value as shown in Figure 4. The address is the sum of
all the switch segments in the ON position. The full DIP switch
address range of 1 to 127 is shown on page 4.
For example, to select a device address of 007, set SW1-1,
SW1-2, and SW1-3 to the ON position and the remaining
switch segments to the OFF position.
Locking base option
The sensors are compatible with a range of bases (see
“Specifications”) and are easily installed by a simple twist and
lock action.
Note: To prevent unauthorised removal of a device from its
base, an automatic locking tab is incorporated into all sensor
mouldings. If the tab is removed, sensors can only be released
from their bases by use of a screwdriver, as shown in Figure 3.
This locking option is applied at the system commissioning
stage.
Maintenance and testing
Basic maintenance consists of a yearly inspection. Do not
modify internal wiring or circuitry.
Automatic self-test
Sensor sensitivity, calibration and self-testing are carried out
automatically by the fire panel. Removal or replacement of an
incorrect sensing device will be identified by the system and
shown as a fault.
Specifications
ZP730-2P/2B
ZP730-2S30 ZP720-3P
ZP732-2P
ZP732-2S30
Operating voltage 19.5 to 20.5 VDC 19.5 to 20.5 VDC
Current
Standby
Alarm
600 µA
700 µA
600 µA
700 µA
Coverage ZP730-2P/2B: 100 m2
ZP730-2S30: 100 m2
ZP720-3P: 50 m2
ZP732-2P: 100 m2
smoke element/
50 m2 thermal element
ZP732-2S30: 100 m2
smoke element/
50 m2 thermal element
IP Rating IP32 IP32
Polarity sensitive Yes Yes
Compatible bases ZP7-IB-P
ZP7-SB1-B
ZP7-SB1-P
ZP7-RB1-P
ZP755B-2P
ZP755BV-3
ZP755BV-4P
ZP755BV-5P
ZP7-IB-P
ZP7-SB1-B
ZP7-SB1-P
ZP7-RB1-P
ZP755B-2P
ZP755BV-3
ZP755BV-4P
ZP755BV-5P
Compatible
accessories Z-RL4 Remote LED
unit Z-RL4 Remote LED
unit
Operating
temperature
Storage
temperature
Relative
humidity
–10 to +75°C
–20 to +70°C
20 to 95%
noncondensing
–10 to +85°C
–20 to +70°C
20 to 95%
noncondensing
Dimensions (Ø x H) 106 × 52 mm ZP720-3P:
106 × 52 mm
ZP732-2P:
106 × 58 mm
ZP732-2S30:
106 × 58 mm
Weight 105 g ZP720-3P: 85 g
ZP732-2P: 105 g
ZP732-2S30: 105 g
Regulatory information
This section includes both regulatory information and a
summary on the declared performance according to the
Construction Products Regulation 305/2011. For detailed
information refer to the product Declaration of Performance.
Certification
Certification body 0370
Declaration of
Performance number
ZP720-3P
ZP730-2P/2B/2S30
ZP732-2P/2S30
360-4211-0399
360-4211-0199
360-4211-0299
Year of first CE marking 05
Product Identification ZP720-3P
ZP730-2P
ZP730-2B
ZP730-2S30
ZP732-2P
ZP732-2S30
www.acornfiresecurity.com
www.acornfiresecurity.com
Intended use See DoP point 3
Essential characteristics See DoP point 9
Manufacturer Gulf Security Technology Co.,Ltd
80, Changjiang East Road,
QETDZ, Qinhuangdao,
Hebei Province, China 066004
Authorized EU manufacturing
representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert,
Netherlands
European Union directives 1999/5/EC (R&TTE directive): Hereby,
UTC Fire & Security declares that this
device is in compliance with the essential
requirements and other relevant
provisions of Directive 1999/5/EC.
2002/96/EC (WEEE directive): Products
marked with this symbol cannot be
disposed of as unsorted municipal waste
in the European Union. For proper
recycling, return this product to your local
supplier upon the purchase of equivalent
new equipment, or dispose of it at
designated collection points. For more
information see: www.recyclethis.info.
www.acornfiresecurity.com
www.acornfiresecurity.com
www.acornfiresecurity.com
www.acornfiresecurity.com

This manual suits for next models

6

Other Ziton Security Sensor manuals

Ziton ZP7BMR-50 User manual

Ziton

Ziton ZP7BMR-50 User manual

Ziton Z600 Series Assembly instructions

Ziton

Ziton Z600 Series Assembly instructions

Ziton ZR432-2P User manual

Ziton

Ziton ZR432-2P User manual

Ziton ZR432-2P Assembly instructions

Ziton

Ziton ZR432-2P Assembly instructions

Ziton ZP700 Series Assembly instructions

Ziton

Ziton ZP700 Series Assembly instructions

Popular Security Sensor manuals by other brands

Ansel AlphaTec 66-600 Series Instructions for use

Ansel

Ansel AlphaTec 66-600 Series Instructions for use

Vaxcel Lambda T0625 Assembly and installation instructions

Vaxcel

Vaxcel Lambda T0625 Assembly and installation instructions

Bresser 7009981 instruction manual

Bresser

Bresser 7009981 instruction manual

Sensit HXG-3 instruction manual

Sensit

Sensit HXG-3 instruction manual

CPAT FLEX DRV3 user manual

CPAT

CPAT FLEX DRV3 user manual

schmersal RSS 36-I2-D-ST5 manual

schmersal

schmersal RSS 36-I2-D-ST5 manual

ABB SMD-W3.1A manual

ABB

ABB SMD-W3.1A manual

ATS BULLSEYE user manual

ATS

ATS BULLSEYE user manual

AGD 641-500-021 product manual

AGD

AGD 641-500-021 product manual

Trotec BE14 operating manual

Trotec

Trotec BE14 operating manual

PCB Piezotronics 124A24 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 124A24 Installation and operating manual

Triple Plus CLM-FDAMAP-1-00 quick start guide

Triple Plus

Triple Plus CLM-FDAMAP-1-00 quick start guide

Tractel Blocfor B10 AES Operating and maintenance instructions

Tractel

Tractel Blocfor B10 AES Operating and maintenance instructions

ESYLUX MD 180i/16 BASIC CH operating instructions

ESYLUX

ESYLUX MD 180i/16 BASIC CH operating instructions

Ecolink WST-702 installation instructions

Ecolink

Ecolink WST-702 installation instructions

Dors 200 user manual

Dors

Dors 200 user manual

GEZE GC 304 R manual

GEZE

GEZE GC 304 R manual

Ciel EaM Batz 2.0 manual

Ciel EaM

Ciel EaM Batz 2.0 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.