© 2021 Carrier. All rights reserved. 1 / 4 P/N 10-4211-501-ZP01-02 • ISS 04OCT21
ZP700 Series Addressable Detector
Installation Sheet
1
2
3
4
EN: Installation Sheet
Description
ZP700 Series Addressable Detector models are shown below.
Table 1: Models
Number
Description
ZP720
-3P Addressable Thermal Sensor, Polar White
ZP730
-2P Addressable Optical Smoke Sensor, Polar White
ZP73
2-2P Combination Smoke and Heat Detector, Polar White
Figures
Figure
1: Inserting the detector
Figure 2: Position of the locking tab
Figure
3: Removing a locked detector
Figure
4: Setting the address
Installation
Note: For general guidelines on system planning, design,
installation, commissioning, use and maintenance, refer to the
EN 54-14 standard and local regulations.
To install a detector:
Insert the detector head into the mounting base and rotate it
clockwise until it clicks into place (Figure 1).
The detector may be locked into the mounting base if required.
To do this, remove the locking tab before installation shown in
Figure 2.
After installation, ensure that the detector communicates with
the control panel. Always test detectors after installation.
To remove a locked detector:
1. Insert a small screwdriver into the locking tab slot
(Figure 3).
2. Press and rotate the detector anticlockwise.
2 / 4 P/N 10-4211-501-ZP01-02 • ISS 04OCT21
Setting the address
The detectors include a seven-segment DIP switch (SW1) for
assigning device addresses. Each switch segment has a
decimal value as shown in Figure 4. The address is the sum of
all the switch segments in the ON position. The full DIP switch
address range of 1 to 127 is shown on page 4.
For example, to select a device address of 007, set SW1-1,
SW1-2, and SW1-3 to the ON position and the remaining
switch segments to the OFF position.
Locking base option
The sensors are compatible with a range of bases (see
“Specifications” below) and are easily installed by a simple
twist and lock action.
Note: To prevent unauthorised removal of a device from its
base, an automatic locking tab is incorporated into all sensor
mouldings. If the tab is removed, sensors can only be released
from their bases by use of a screwdriver, as shown in Figure 3.
This locking option is applied at the system commissioning
stage.
Maintenance and testing
Basic maintenance consists of a yearly inspection. Do not
modify internal wiring or circuitry.
Automatic self-test
Sensor sensitivity, calibration and self-testing are carried out
automatically by the fire panel. Removal or replacement of an
incorrect sensing device will be identified by the system and
shown as a fault.
Specifications
Operating vol
tage 19.5 to 20.5 VDC
Current
Standby
Alarm
600 µA
700 µA
Coverage
ZP720-3P
ZP730-2P
ZP732-2P
Smoke element
Thermal element
50 m2
100 m2
100 m2
50 m2
IP Rating
IP32
Polarity sensitive
Yes
Compatible bases
ZP7-IB-P
ZP7-SB1-P
ZP7-RB1-P
ZP755B-2P
ZP755BV-3
ZP755BV-4P
ZP755BV-5P
Compatible accessories
Z-RL4 Remote LED unit
Environmental
Operating temperature
ZP720-3P
ZP730-2P
ZP732-2P
Storage temperature
Relative humidity
–10 to +85°C
–10 to +75°C
–10 to +85°C
–20 to +70°C
20 to 95% noncondensing
Dimensions (Ø x H)
ZP720-3P
ZP730-2P
ZP732-2P
106 × 52 mm
106 × 52 mm
106 × 58 mm
Weight
ZP720-3P
ZP730-2P
ZP732-2P
85 g
105 g
105 g
Regulatory information
This section provides a summary on the declared performance
according to the Construction Products Regulation
(EU) 305/2011 and Delegated Regulations (EU) 157/2014 and
(EU) 574/2014.
For detailed information, see the product Declaration of
Performance (available at firesecurityproducts.com).
Certification
Certification body
0370
Declaration of
Performance number
ZP720-3P
ZP730-2P
ZP732-2P
360-4211-0399
360-4211-0199
360-4211-0299
Year of first CE marking
05
Product Identification
See model number on product
identification label
Intended use
See the product Declaration of
Performance
Declared performance
See the product Declaration of
Performance
Manufacturer
Carrier Safety System (Hebei) Co. Ltd.,
80 Changjiang East Road, QETDZ,
Qinhuangdao 066004, Hebei, China.
Authorized EU manufacturing
representative:
Carrier Fire & Security B.V.,
Kelvinstraat 7, 6003 DH Weert,
Netherlands.
2012/19/EU (WEEE directive): Products
marked with this symbol cannot be
disposed of as unsorted municipal waste
in the European Union. For proper
recycling, return this product to your local
supplier upon the purchase of equivalent
new equipment, or dispose of it at
designated collection points. For more
information see: recyclethis.info
Contact information and product
documentation
For contact information or to download the latest product
documentation, visit firesecurityproducts.com.
P/N 10-4211-501-ZP01-02 • ISS 04OCT21 3 / 4
Product warnings and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO AND
INSTALLATION BY QUALIFIED PROFESSIONALS.
CARRIER FIRE & SECURITY B.V. CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR
“AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE AND
SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers
and product safety information, please check
https://firesecurityproducts.com/policy/product
-
warning/
or scan the QR code:
4 / 4 P/N 10-4211-501-ZP01-02 • ISS 04OCT21

This manual suits for next models

3

Other Ziton Security Sensor manuals

Ziton ZP7BMR-50 User manual

Ziton

Ziton ZP7BMR-50 User manual

Ziton Z600 Series Assembly instructions

Ziton

Ziton Z600 Series Assembly instructions

Ziton ZP700 Series Assembly instructions

Ziton

Ziton ZP700 Series Assembly instructions

Ziton ZR432-2P User manual

Ziton

Ziton ZR432-2P User manual

Ziton ZR432-2P Assembly instructions

Ziton

Ziton ZR432-2P Assembly instructions

Popular Security Sensor manuals by other brands

AEMC 275HVD user manual

AEMC

AEMC 275HVD user manual

Aritech EV400-PLUS Series quick start guide

Aritech

Aritech EV400-PLUS Series quick start guide

Raven SID-20200 manual

Raven

Raven SID-20200 manual

Comelit 41RCS100 Installation instruction

Comelit

Comelit 41RCS100 Installation instruction

Panasonic 6295 manual

Panasonic

Panasonic 6295 manual

DANLERS CBU-HBWD IP66 Series manual

DANLERS

DANLERS CBU-HBWD IP66 Series manual

Autronica AutroFlame X33AF Addendum

Autronica

Autronica AutroFlame X33AF Addendum

System Sensor ECO1002 Installation and maintenance instructions

System Sensor

System Sensor ECO1002 Installation and maintenance instructions

Omron DST1 Series datasheet

Omron

Omron DST1 Series datasheet

SHOCK ALERT 42500 quick start guide

SHOCK ALERT

SHOCK ALERT 42500 quick start guide

STEINEL 067304 manual

STEINEL

STEINEL 067304 manual

iNels RFSF-100 quick start guide

iNels

iNels RFSF-100 quick start guide

Mitsubishi Electric PAC-USSEN001-FM-1 Installation instructions manual

Mitsubishi Electric

Mitsubishi Electric PAC-USSEN001-FM-1 Installation instructions manual

Safety Technology International 34701 quick start guide

Safety Technology International

Safety Technology International 34701 quick start guide

AMC IF16T Installation

AMC

AMC IF16T Installation

Lenel m3000 installation guide

Lenel

Lenel m3000 installation guide

Pilz PSEN sl-0.5n 2.1 operating manual

Pilz

Pilz PSEN sl-0.5n 2.1 operating manual

Det-Tronics FlexSonic instructions

Det-Tronics

Det-Tronics FlexSonic instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.