ZURN AquaSense AV ZEMS-IS Series User manual

®
AquaSense
®AV
ZEMS-IS Series w/
HW 6PowerConverter
Autom aticSensor-OperatedExposedFlushom eter
Installation,Operation,Maintenance
and PartsManual
Patented and Patents Pending
LIMITED WARRANTY
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are
notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the
defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the
purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability
is expressly excluded. If the products sold hereunder are “ consumer products,” the implied warranty of merchantability is limited to a
period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are
approximate and are not guaranteed.
SensorOperated Exposed Flushom eter
ZEMS6000AV-IS Closet
ZEMS6003AV-IS Urinal
ZEMS6000AV-IS
ZEMS6003AV-IS

FV343 Rev N 4/16/10
Page 2
PRIOR TO INSTALLATION
Priortoinstallingthe ZurnAutomaticSensor-equippedFlushometer,installthe itemslistedbelow.
•Allplumbingistobe installedinaccordance withapplicable codesandregulations.
•W atersupplylinesmustbe sizedtosupplyanadequate volume ofwaterforeachfixture.
•Flushallwaterlinespriortomakingconnections.
•SensorUnitsshouldnotbe locatedacrossfrom eachotherorinclose proximitytohighlyreflective surfaces.
The ZurnAquaVantage®valve isdesignedtooperate overthe entire pressure range recommendedbyplumbingfixture
manufacturersandwillproduce ameteredflushwhenactivated.
Protectthe chrome orspecialfinishofthisAquaVantage®valve.Do not use toothed tools to install or service the valve.
Also,see "Care andCleaning"sectionofthismanual.
ZEMS6000AV-IS CLOSET
ZEMS6003AV-IS URINAL
TYPICALINSTALLATION
RED
VDC
BLUE
GND
CAUTION:
RISKOF ELECTRICSHOCK
DRYLOCATIONUSE ONLY
R
REGULATEDPOWERSUPPLY
PARTNO: 200097001
MODELNO : P6000-HW6
I/P:120VAC/320mA@Fullload,60Hz
O/P:+7.6.0VDCmin@2Aload
DUTYCYCLE:2sec"On",60sec"Off"
DeltaElectronics(Thailand)PublicCo.,Ltd.
7.6VDC
OUT
BLACK
BLACKwith
WHITESTRIPE
BLUE(-)
RED(+)
WHITE
BLACK
120VAC
IN
P6000-HW6 WIRING
TOFAUCET
ORFLUSHVALVE
E323168
MADEINTHAILAND
C US
U
L®
"UseCopperconductoronlyand
seedetailsininstructioinmanual"
"ForGroundingConductor,Use18
AWGminimum"
WARNING:
Toreduceriskoffireorelectric
shock-Donotinterconnect
outputterminations.
RED
VDC
BLUE
GND
CAUTIO N:
RISKOF ELECTRICSHOCK
DRYLOCATIONUSE ONLY
R
REGULATEDPOWER SUPPLY
PARTNO: 200097001
MODELNO : P6000-HW6
I/P:120VAC/320mA@Fullload,60Hz
O/P:+7.6.0VDCmin@2Aload
DUTYCYCLE:2sec"On",60sec"Off"
DeltaElectronics(Thailand)PublicCo.,Ltd.
7.6VDC
OUT
BLACK
BLACKwith
WHITESTRIPE
BLUE(-)
RED(+)
WHITE
BLACK
120VAC
IN
P6000-HW6 WIRING
TOFAUCET
ORFLUSHVALVE
E323168
MADE INTH AILAND
C US
U
L®
"UseCopperconductoronlyand
seedetailsin instructioinm anual"
"ForGroundingConductor,Use18
AWGminimum"
WARNING:
Toreduceriskoffireorelectric
shock-Donotinterconnect
outputterminations.
HW 6 POW ER
CONVERTER
HW 6 POW ER
CONVERTER
POW ER CORD
FURNISHED
BY ZURN
MOTOR
ACTUATOR
W /SENSOR
3
4[19]
I.P.S.
SUPPLY
FINISHED W ALL
21
4[57] MIN.
41
4
111
2[292]
47
16[113]
43
4±1
2
[121±13]
3
4[19]
VACUUM
BREAKER
TUBE
97
8[251]
47
16[113]
97
8[251]
MOTOR
ACTUATOR
W /SENSOR
111
2[292]
11
2[38]
VACUUM
BREAKER
TUBE
1[25]
I.P.S.
SUPPLY
21
4[57] MIN.
41
4[108] MAX.
FINISHED W ALL
43
4±1
2
[121±13]
TOP OF FIXTURE
TOP OF FIXTURE
POW ER CORD
FURNISHED
BY ZURN

FV343 Rev N 4/16/10
Page 3
TOP OF FIXTURE
Ø1 3/4
1 1/2 [Ø44
38]HOLE
THROUGH
W ALL
111
2[292]
31
8[79]
43
4[121]
13
8[35]
101
8[257]
Figure1
Figure2
HW 6PowerConverterInstallation(STEPS 1-4)
•The ZurnHW 6 PowerConvertershallbe installedinaccordance withNational/Localelectricalcodes.
•The HW 6 isshippedintergratedwithina4 11/16"X 4 11/16"X 2 1/8"electricalbox.
•Itisadvisable toinstallthe HW 6 powersupplyinanaccessible location,asclose aspossible tothe flushvalvesitwill
power.Ideallocationisbehindanaccesspanel,inapipe chase,orabove adropceiling.The greatestdistance toanyvalve
shallideallybe lessthan20 ft.,(40 ft.max.).
•The Zurn-HW 6 PowerConvertershallbe directwiredwithcontinuous120VAC,60Hzfrom the buildingsupply.
•The HW 6 canbe usedtopowerupto8 ZEMS-IS flushvalves.
•Enclosedwitheachvalve is1 (one) connectingwire topowerZEMS-IS actuator.
•The wire shallbe wire nutconnectedtothe low voltage red(+) andblue (-) leadsfrom the powersupplyasshownin
(Figure1).
•The connectingwire ispolarized.The blackleadwithwhite trace is(+) andconnectstothe redwire from the powersupply.
The plainblackleadis(-) andconnectstothe blue leadonthe powersupply.Donotcrosswiresasitwillcausedam age
totheproduct!
•Connectingwire shallbe runfrom the powersupplytothe predrilled1-1/2"diameterholesinthe finishedwallforfinal
connectiontothe flushvalves.(Figure2)
IM PORTANT
1. Mustuse aZurnpowersupplytoensure propervoltage forthe system.Correctpolarityisnecessarytopreventdamage to
the sensors.CheckDC powerleveltoensure the powersupplyisprovidingaminimum of7.4 voltsDC.DC levelslessthan
7.4 voltswillresultinmalfunctionofthe units.
2. Be certaintouse the lengthsofwire providedwitheachpowersupplywhenwiringthe bathroom forthe flushvalves.The
connectorandwire gauge have beenselectedspecificallytomatchthe ZurnFlushometervalve.
3. EachFlushValve shouldbe wiredinparallelasshowninthe wiringdiagram below.
4. Ensure the accesshole behindthe flushvalve isaminimum of1-1/2”indiameterandlocatedperZurntemplates#FV329
and #FV330.The plug end ofthe low voltage wire needsto be accessible atthishole when the plumberinstallsthe
flushometervalve.
ZURN ZEMS6000AV-IS
Valve Rough In
Dim ensions
P6000-HW 6
120 VAC IN
7.6 VDC OUT
(+) BLACK W /
W HITE STRIPE
(-) BLACK
(+) BLACK W /
W HITE STRIPE
(-) BLACK
(+) RED
(-) BLUE
(-) BLACK
(+) BLACK W /
W HITE STRIPE
BLACK
(LINE)
W HITE
(NEUTRAL)
GREEN
(GROUND)
120
VAC
OPTIONAL -PC6
POW ER CONVERTER (+) BLACK W /
W HITE STRIPE
(-) BLACK
RED
VDC
BLUE
GND
CAUTION:
RISK OF ELECTRICSHOCK
DRYLOCATION USE ONLY
R
REGULATEDPOW ER SUPPLY
PARTNO : 200097001
MODELNO : P6000-H W6
I/P: 120VAC/320mA@ Fullload,60Hz
O/P : +7.6.0VDCmin@2A load
DUTYCYCLE: 2sec"On",60 sec"Off"
DeltaElectronics(Thailand)Public Co.,Ltd.
7.6V DC
OUT
BLACK
BLACKwith
WHITESTRIPE
BLUE(-)
RED(+)
WHITE
BLACK
120VAC
IN
P6000-HW6 W IRING
TO FAUCET
ORFLUSHVALVE
E323168
MADE INTHAILAND
C US
UL
®
"UseCopperconductoronlyand
seedetailsininstructioinmanual"
"ForGroundingConductor,Use18
AWG m inimum"
WARNING:
Toreduceriskoffireorelectric
shock-Donotinterconnect
outputterminations.
Note:ConnecttoeithertheHW 6orPC6powerconverter.

FV343 Rev N 4/16/10
Page 4
COURTESY
FLUSH SW ITCH
STEP 7-ValveInstallation (Figure7)
Installvalve tocontrolstopwiththe bottom ofthe valve tilted
slightlyuptowardsyouandleave the valve nutloose.Make
sure nottodamage o-ringonvalve.Make sure vacuum breaker
andvacuum breakerdiscare properlyinstalledwithinthe flush
tube.Rotate valve downovervacuum breakertube andtighten
tube nuttovalve.Aftertube nutistight,tightenvalve nutto
controlstop.
STEP 9-ActuatorInstallation (Figure9)
Slide wallflange overthe chrome covertube asshown.Connect
the plugconnectoronthe ZEMS-ISactuatorwiththe DC power
pluglocatedwithinthe accesshole justbehindthe flushvalve.
Carefully tuck the wires back into the access hole.Install
handle gasketintoactuatornutandtightenactuatortovalve.
Pushwallflange againstwallandtightensetscrew.
Figure7
Figure9
SUPPLY FLANGE W / SET SCREW
CHROME TUBE COVER
SW EAT SOLDER ADAPTER
CONTROLSTOP
STOP CAP
SCREW COVER
STEP 6-Vacuum BreakerFlush Connection (Figure6)
Place vacuum breakerandvacuum breakerdiscintube as
shown.Slide the tube nut,spudnut,slipwasher,rubbergasket
andspudescutcheonoverthe vacuum breakertube andinsert
tube into fixture spud.Hand tighten spud nuton to fixture
spud.
STEP 5-ControlStop Installation (Figure5)
Installthe Zurncontrolstopvalve andwallescutcheontothe
watersupplyline withthe outletpositionedasrequired.
NOTE:Forsweatsolderapplications,see recommended
instructionsincludedinthe Zurnsweatsolderkit.
Figure5
Figure6
STEP 10-Flush OutSupplyLine(Figure9)
Close controlstop.Remove valve bodycoverandliftouttrip
mechanism.Reinstallinternalcapandvalve bodycover.Turn
onwatersupplytoflushline ofanydebrisorsediment.After
completion,shutoffcontrolstop,remove coverandreinstall
the trip mechanism.Installthe internalcap and valve body
coverwrenchtight.
STEP 8-CourtesyFlushOption(Figure8)
Productis configured attime ofshipmentfora 168 hour
courtesyflush.(SW 1 inOFF position.) Ifa48 hourcourtesy
flushisdesired,remove rearcoverandsetSW 1 toON position.
Figure8

FV343 Rev N 4/16/10
Page 5
FLASHING RED LIGHT
STEP11-CUSTOMIZED SENSOR RANGESETTING
The ZEMS-IS isfactorysettoaccommodate mostclosetand
urinalinstallations.Ifthisfactorysettingdoesnotaccommo-
date yourspecificenvironment,follow stepsbelow tocustom-
ize yourrange settingsforyourspecificZEMS-IS model.
NOTE: IfyourZEMS-ISactuatorhasarubberoverride button,
consultyourlocalZurn representantive forcustomized
sensorrange settingprocedure.1-800-997-3876.
CALIBRATION INSTRUCTIONSFOR ZEMS-IS
1.Obtainatarget.SEE FIGURE 12.
2.PRESS andHOLD buttonfor10 seconds*untilthe LED
turnssolid.
(*Unitwillblinkand flush once while button isbeing held)
3.RELEASE fingerwhenLED turnssolid.Unitiscalibrating.
4.Settargetatdesireddistance,(Nolessthan16") from sen-
sorface andverifyNO otherobjectsare inview ofsensor
face.
5.Keeptargetsteadyuntilthe calibrationcycle endswithtwo
fastblinks.
6.Forclosetinstallationscontinue to"VERIFYCALIBRATION
FOR CLOSET INSTALLATIONS".
CALIBRATION INSTRUCTIONSFOR ZEMS-IS III
1.Obtainatarget.SEE FIGURE 12.
2.PRESS andHOLD buttonfor10 seconds*untilthe LED
turnssolid.
(*Unitwillblinkfourtim esand flush once while button isbeing held)
3.RELEASE fingerafterLED turnssolid.
4.PRESS andHOLD buttonwhenLED startsblinking.
5.RELEASE fingerwhenLED turnssolid.
6.Settargetatdesireddistance,(Nolessthan16") from sen-
sorface andverifyNO otherobjectsare inview ofsensor
face.
7.Keeptargetsteady-Unitwillblinkwhile calibrating.
8.After15seconds,calibrationendswithafastdouble blink
orasolidLED for5seconds.
9.IF THE LED REMAINS SOLID FOR 5SECONDSAFTER
CALIBRATION,the calibrationwasNOT successful.RE-
PEAT STEPS 2-8
10.Forclosetinstallationscontinue to "VERIFY CALIBRA-
TION FOR CLOSET INSTALLATIONS".
VERIFYCALIBRATION FOR CLOSETINSTALLATIONS
1.Standoutside closetstallandclose door.
2.Slowlyopendoortoclosetstallwhile lookingatZEMS-IS
sensor.
3.Ifledblinkswhile doorisopening,recalibrate toashorter
range. FAILURE TO DO SO W ILLRESULT IN GHOST
FLUSHING.
STEP 12-ActivatingtheMotorActuatorwiththeSensor
Toactivate the motoractuatorwiththe sensor,simplyplace a
targetinfrontofthe sensor.Asingle redlightwillflashindicat-
ingthe sensorhasrecognizedthe target.Ifthe targetstaysin
view forelevenseconds,twoflashingredlightswilloccur.This
indicatesthatthe targethasbeeninview forthe requiredtime
anduponleavingthe view,asignalwillbe senttothe motor
actuatortoflushthe flushvalve.NOTE: Ifthe targetdoesnot
stayinview forthe requiredelevenseconds,aflushwillnot
occur.
Figure10
Figure11
Figure12
Recommended Distance Settings: *
Urinal 22" from sensor face.
Closet 6" - 8" beyond front lip of
toilet bowl.
TARGET
MANUALBUTTON
RECOMMEND
BROW N CARDBOARD
TARGET
(16"X 16")
*W arning: Calibrating to a
distance less than 18"
mayresultin false
activations.

FV343 Rev N 4/16/10
Page 6
Parts Identification
1. Cast Wall Escutcheon
2. Setscrew for Cast Wall Escutcheon
3. Supply Cover Tube
4. Sweat Solder Adapter
5. Stop Body
6. Piston Seal
7. Piston
8. Stop Spring
9. Guide O-Ring
10. Piston Guide
11. Guide Holder
12. Adjusting Screw
13. Stop Cap
14. Snap Cap Screw Cover
15. Vandal-Resistant Control Stop Cover
16. Setscrew for Control Stop Cover
17. Locking Nut
18. Tailpiece O-Ring
19. Snap Ring
20. Tailpiece
21. Valve Body Cover
22. Plastic cover
23. Trip M echanism
24. Diaphragm Repair Kit
25. Valve Body
26. Gasket
27. ZEM S-IS Actuator Assembly
28. Vacuum Breaker Disc
29. Vacuum Breaker
30. 1-1/2" Vacuum Breaker Tube
31. Vacuum Breaker Tube Nut
32. 1-1/2" Spud Nut
33. 1-1/2" Spud Friction Washer
34. 1-1/2" Spud Sleeve
35. Spud Escutcheon
36. 3/4" Vacuum Breaker Tube
37. 3/4" Spud Nut
38. 3/4" Spud Friction Washer
39. 3/4" Spud Sleeve
40. 3/4" Spud Escutcheon
41. Power Cord
42. 120VAC/6 VDC Plug-in Power
Converter (Un-Regulated)
43. Power Converter P6000-HW 6 (Regulated Supply)
®
Covers and Repair Kits Product No.
Outside Cover - Item 21 P6000-LL
Inside Cover - Item 22 P6000-L
High Effeciency Closet Kit - 1.28 gal. flush P6000-ECA-HET
Low Consumption Closet Kit - 1.6 gal. flush P6000-ECA-W S1
Water Saving Closet Kit - 3.5 gal. flush P6000-ECA-W S
Full Flow Closet Kit - 4.5gal. flush P6000-ECA-FF
Ultra Low Flow Urinal Kit - 0.125gal. flush P6000-EUA-ULF
Low Consumption Urinal Kit - 1.0gal. flush P6000-EUA-W S1
Water Saving Urinal Kit - 1.5gal flush P6000-EUA-W S
Full FlushUrinal Kit - 3.0gal. flush P6000-EUA-FF
Repair Parts -Inside Parts Product No.
Urinal Trip M echanism - Item 23 P6000-EUA13
Closet Trip M echanism - Item 23 P6000-ECA13
Aquavantage Rebuild Kits Product No.
Closet and Urinal Rebuild Kits Include
P6000-ECA-WS-RK
Items 18,23,24,26,28,29
P6000-ECA-W S1-RK
P6000-ECA-HET-RK
P6000-EUA-WS-RK
P6000-EUA-W S1-RK
P6000-EUA-ULF-RK
Actuator Assembly and Repair Kits Product No.
M otor Actuator/Sensor (Item 27) PEMS6000-HYM-IS
Power Cord (Item 41) PEM S6000-CW
120VAC/7.6 VDC Plug-in Power Converter (Item 42)P6000-PC6
Power Converter (Item 43) P6000-HW 6
Handle Gasket Includes Item 26 P6000-M 10
ControlStop Repair Kit and Parts Product No.
Control Stop Repair Kit for 1”and 3/4”, P6000-D-SD
Includes Items 6-12
Seal Seat for 1”and 3/4”,Includes Item 6 P6000-D42
Sweat Solder Adapter P6000-YBA
Adjustable Tailpieces Product No.
Adjustable Tailpiece for Standard FlushValve P6000-J1
Includes Items 18-20
Tailpiece Locking Ring Includes Item 19 P6000-C30
Tailpiece O-Ring Includes Items 18 P6000-C31
Coupling Nut Includes Item 17 P6000-C32
Flush Connections and Spud Coupling Kits Product No.
1-1/2" FlushConnection and Spud Coupling P6000-H
3/4" FlushConnection and Spud Coupling P6003-H
Vacuum Breaker Repair Kit Includes Items 28,29 P6000-B
Spud Coupling Assembly (Specify Size ) P6000-HN
AquavantageZEMS-IS PartsBreakdown
RED
VDC
BLUE
GND
CAUTION:
RISKOF ELECTRICSHOCK
DRYLOCATIONUSE ONLY
R
REGULATEDPOWER SUPPLY
PARTNO : 2 00097001
MODELNO :P 6000-HW6
I/P: 120VAC/320mA@Fullload,60Hz
O/P: +7.6.0VDCmin@2Aload
DUTYCYCLE: 2sec"On",60sec"Off"
DeltaElectronics(Thailand)PublicCo.,Ltd.
7.6VDC
OUT
BLACK
BLACKwith
WHITESTRIPE
BLUE(-)
RED(+)
WHITE
BLACK
120VAC
IN
P6000-HW 6 W IRING
TOFAUCET
ORFLUSHVALVE
E323168
MADEINTHAILAND
C US
UL®
"UseCopperconductoronlyand
seedetailsininstructioinmanual"
"ForGroundingConductor,Use18
AWG minimum"
WARNING:
Toreduceriskoffireorelectric
shock-Donotinterconnect
outputterminations.

FV343 Rev N 4/16/10
Page 7
Care of Chrome plated surfaces.
The suggested cleaning of chrome plated surfaces is simply to clean them with soap and water then dry. Commercial cleaning compounds are never
recommended.
Seasonal use.
Valves used in installations subject to shut down because of cold and freezing conditions should be maintained in the following manner. After the main
supply has been shut off and the water drained from the system,remove the stop valve cap and stop internals to allow the water to drain from the
flush valve itself.
Problem
Valve will not operate.
Cause* Corrective Action*
ZEM S-ISAQUAVANTAGE TROUBLE SHOOTING
1.)Stop valve is closed
2.)Supply valve is closed.
1.)Open Stop valve.
2.) Open supply valve.
1.)Stop valve not open enough.
2.)Urinal trip mechanism installed in closet kit. Urinal
kit installed in closet valve,or 1.0gal. urinal kit
installed in place of 1.5gal urinal kit.
3.) Insufficient volume or pressure at supply.
Insufficient volume of water to
adequately flushfixture.
1.)Open stop valve for desired volume of water.
2.)Install appropriate parts or kit.
3.)If gauges are not available to measure supply pres-
sure or volume of water at the valve,completely
remove the working parts and open the stop valve to
allow water to pass throughthe empty valve. If the
water supply proves unsatisfactory,steps should
be taken to increase the pressure and/or supply.
Flushvalve shuts off too quick. 1.)Damaged or punctured diaphragm.
2.)Enlarged by-pass orifice.
1.)Install new replacement kit to remedy the
problem.
2.)Install new replacement kit to remedy the
problem.
3.)Screw the two assemblies hand tight.
4.)Install new Z6000-ECA,Z6000-EUA replace-
ment kit to remedy the problem.
5.)Install closet trip mechanism (white).
3.)Cylinder guide assembly and diaphragm assembly are
not tight.
4. )Enlarged by-pass orifice.
5.)Urinal trip mechanism (black)in closet flushvalves.
Valve is flushing too long or not
shutting off.
1.)Trip mechanism not seating properly due to foreign
material between trip mechanism and retainer disc.
2.)By-pass orifice is plugged or partially plugged.
3.)Line pressure is not adequate to force trip mechanism
to seal.
4.)Cracked cover.
1.)Disassemble parts and rinse thoroughly.
2.)Examine by-pass orifice and clean if necessary being
certain not to enlarge orifice opening.
3.)Pressure is inadequate or has dropped below mini-
mum operating range. Steps should be taken to in-
crease the line pressure.
4.)Replace cover withnew one.
Water splashes out of fixture. 1.)Supply volume is more than is necessary.
2.)Lime accumulation on vortexor spreader holes of
fixture.
1.)Adjust downward on control stop.
2.)Remove the lime build up within the fixture.
Flushis not considered quiet. 1.)Control stop may not be adjusted for quiet
operation
2.)Fixture may be contributing to noise
3.)Piping system may be source of noise.
1.)Adjust the control stop for quiet operation keeping
in mind the fixture evacuation requirements.
2.)Checknoise created by fixture by placing a cover
over the bowl opening to separate valve noise from
bowl noise. If it is determined the fixture is too
noisy consult withfixture manufacturer.
3.)Highpressure in the system can sometimes be con-
trolled by the stop valve. Other sources of noise
may be the absence of air chambers and shockar-
restor,loose pipes,improper size pipes,etc. In
these cases the building engineer should be con-
sulted.
1.)Lens may be dirty.
2.)Power supply output is out of tolerance.
3.)Sensor is viewing stall door.
1.)Clean lens.
2.)DC voltage must be between 7.4-9volts. Check
for power fault or malfunction in a unit or replace
witha Zurn power converter.
3.)Re-calibrate sensor per step 11.
Sensor assembly leaking 1.)Sensor assembly is not tight. 1.)Tighten sensor assembly.
1.)Sensor does not recognize a user.
2.)Power supply may be disrupted.
1.)Re-calibrate sensor per step 11.
2.)Checkavailable voltage where escutcheon is
attached to wall withDC voltmeter. 7.4-9VDC is
required.
Flushvalve does not activate
after user leaves.
Flushvalve "ghost" flushes or
activates randomly withno user
present.
Valve activates repeatedly when
power is provided.
1.)Insufficient DC power level (less then 7.4volts DC) 1.)Upgrade the -HW 6 power supply to the new
ZURN power supply (greater than 7.4volts DC)or
replace the PC6 supply.

FV343 Rev N 4/16/10
Page 8
ZURN INDUSTRIES,LLC.
COMMERCIAL BRASS OPERATION
5900 ELW IN BUCHANAN DRIVE
SANFORD NC 27330
Phone:1-800-997-3876
Fax:919-775-3541
W orld W ide W eb:www.zurn.com