2gig Technologies Go!Control Panel User manual

WARNING: OWN ER’S I NS TRUCTI ON NOT ICE
Not to be removed by anyone except occup ant
Go!Control Panel
User Guide
ENGLISH
(Internaonal)
WIRELESS SECURITY SYSTEM


CONTENTS
Copyright © 2015 Nortek Security & Control LLC 1
SystemOverview ..................3
Features .............................3
BasicOperation .......................4
SensorTypes/Zones .................4
Smoke,Heat,andFreezeProtection....4
BurglaryProtection ..................4
UserCodes .........................4
Alarms ............................4
Messages..........................4
TroubleAlerts ......................4
WirelessSensors....................4
ControlPanelFeatures.................5
MainDisplayScreens ..................6
HomeScreen.......................6
SecurityScreen .....................6
ReadytoArmScreen.................6
MenuScreen.......................6
StatusScreen .......................6
BurglaryProtection................7
SampleFloorPlan .....................7
SensorStatus.........................8
checkingforclosedSensors.............8
ViewingEachSensor’sStatus............9
DealingwithaSensorFalseAlarm........9
SensorBypassing.....................10
ForceBypassAllSensors .............10
Bypassing/Un‐BypassingSensors ......10
StayMode..........................11
EntryDelayinStayMode............11
QuickExitinStayMode .............12
SilentControlinStayMode............12
ArmingtoStayMode ...............12
Awaymode .........................13
ExitandEntryDelaysinAwaymode...13
ExitDelayRestart...................13
SilentControlinAwayMode.........13
QuickExitinAwayMode ............14
AutoStayMode ....................14
ArmingtoAwayMode ..............14
DisarmingtheSystem .................15
DisarmingfromStayMode...........15
DisarmingfromAwayMode..........16
IfaBurglaryAlarmOccurs .............16
BurglaryAlarmSiren ................16
AlarmMemory ....................16
Optional2‐WayVoiceCommunications 17
KeyFob:ArmingandDisarming.........17
ArmtheKeyfob....................17
DisarmtheKeyfob ..................17
ActivatetheEmergencyAlarm........17
ActivatetheAuxiliaryOutput .........17
WirelessKeypad:ArmingandDisarming .18
ArmtheKeypad ....................18
DisarmtheKeypad .................18
ActivateaFireEmergency ...........18
ActivateaPoliceEmergency..........18
Smoke,HeatandFreezeProtection ..19
InitiatingaFireAlarmManually.......19
IftheFireAlarmSoundsAutomatically . 19
SilencingaFalseFireAlarm ..........20
RecommendedFireAlarmLocations.....21
NFPAStandard#72.................21
DoNotMountanAlarmHere:.......21
EmergencyActionPlan .............22
EmergencyFunctions .............23
24‐HourEmergencyButtons...........23
SystemTroubleAlerts.............24
TroubleAlertIcon ...................24
ViewtheCurrentTroubleAlerts ........24
TroubleAlertBeepHold‐off ...........24
SystemStatusIcons ..............25
ACPowerOn .......................25
ACPowerOFF.......................25
PhoneLineFailure ...................25
SounderDisabled....................25
LowBackupBattery ..................25
TestMode ..........................25
Touc hScreenKeypadTraffic ...........25
CellRadio..........................25
Interiorsensoropen .................25
Messaging ......................26
DisplayingMessages .................26
ReadingMessages...................26
ReadingConfidentialMessages .........27
FilteringMessages ....................27
SortingMessages .....................27
RemoteControlbyTelephone ......28
CallingtheSystem...................28
ControllingtheSystemRemotely .......28
BypassingSensorsRemotely...........29
SystemToolbox ..................30
Usermanagement ...................30
UserCodeSetup...................30
AddingaUserCode................30
UserCodeAccessSchedules .........31
UserCodes .......................32
DuressUserCodeSetup ............33
SecretDuressButton ...............33
SystemHistory......................34
SystemTest . ........................34
SensorTest .......................35
PanelTest ........................35
TelephoneTes t ....................35
CellPhoneTest ....................36
ChimeOptions.......................37
AdjustingtheBrightness/Volume.......38
AdjustingtheBacklightTime‐out.......38
CleaningtheTouc hScreen ............38
Touc hScreenCalibration..............39
SetDateandTime ...................40
DisplayFirmwareVersion .............40
InstallerProgrammedOptions......41
SirenRunTime....................41
SensorTriggerLimit ................41
FireHornRunTime ................41
ExitDelay ........................41
EntryDelay.......................41
24‐HourEmergencyFunctions.......42
QuickArming .....................42
QuickBypass......................42
QuickExit ........................42
AutoUn‐bypass ...................42

Go!Control Wireless Security System | User Guide
2Copyright © 2015 Nortek Security & Control LLC
AutoStay .........................42
KeyFobSound.....................42
KeyFobDisarmAfterSound .........43
KeyFobOptions ...................43
WirelessKeypadEmergencyKeys .....43
ExitDelayRestart ..................43
CancelDisplay .....................44
CancelTime .......................44
DialerDelay .......................44
2‐WayVoice.......................44
TelephoneRemoteControlAnswer ...44
InstallerSpecificInformation.......45
ServiceInformation ...............46
AlarmDialingEquipment ..........47
RegulatoryInformation............48
ImportantNotice .................49
AlarmSystemLimitations .............49
LimitedWarranty.................51

Copyright © 2015 Nortek Security & Control LLC 3
SYSTEM OVERVIEW
Thissystemprovidesthree(3)formsofprotection:burglary,fire,andemergency,depending
ontheoptionssetbyyourinstaller.ThesystemconsistsoftheControlPanelwithacolor
touchscreen,wirelesssensorsthatprovideperimeterandinteriorburglaryprotection,and
wirelesssmokeandcarbonmonoxidedetectors.Inaddition,optionalremotecontrolkeyfobs,
wirelesspanicbuttonsandkeypadsmayhavebeenprovidedorinstalled.
Thesystemmonitorsallprotection“zones”andthesystem’sstatus.TheControlPaneldisplays
monitoringinformationandcontrolsthealarmsiren.Yoursystemmayalsohavebeensetup
tosendalarmandstatusreportstoaCentralStationandhasthecapabilityfor2‐wayvoice
communicationswiththealarmmonitoringoperator.
FEATURES
Followingisalistofstandardfeaturesandoptionsthatcanbeincludedinyoursystem.Ask
yourinstallerwhichoptionsareavailabletoyouandchecktheboxesthatapply.
•StayandAwayarmingmodes:Staymodearmsthesystemperimeteronlyandisused
typicallyatnightwhenthepremisesareoccupied.Awaymodearmsthesystemperimeter
andinterior;it’susedwhenthepremisesareunoccupied.
•32user‐unique4‐digitcodestooperatethesystem:Thesystemsupportsone(1)master
usercodethatcanassignandmaintaintheotherusercodes.
•Oneofthe32usercodesfunctionsasaduresscode.Controllingthesystemwiththiscode
givestheappearanceofnormaloperation,butusingitsendsasilentduressreporttothe
CentralStationtoinitiateasilentalarmcallforhelp.
•VoiceannouncementsfromtheControlPanel:Thesystemhasavocabularyofdescriptive
wordsthatcanbeassignedtosensorssoeachhasauniqueannouncementsuchas“front
door”or“bedroomwindow”ifdesired.
•Homeautomationwiththebuilt‐inZ‐WavecontrollerforremotecontrollingZ‐Wave
enabledhomeappliances(optionalfeature).
•Alarmhistorywithsystemeventlog:Eachalarmandsystemalertisloggedintothe
system’smemory.TheseeventscanbedisplayedandreviewedattheControlPanelor
remotelybytheCentralStation.
•Realtimeclockandcalendarshowsonthesystem’sdisplayandisusedtotimestamp
itemsintheeventlog.
2‐wayvoicecommunication:Afteranalarm,thesystemcanautomaticallyconnectwitha
CentralStationoperatorsotheycanconversewithpeopleinthepremises.
Remotecontrolofthesystemoverthetelephone.1
RemotecontrolofthesystemusingaWeb‐enableddevicethroughtheInternet2
Threeoptional24‐houremergencyfunctions:Panic,Fire,andEmergency.Thesefunctions
canbeactivatedbybuttonsontheControlPanel,usingwirelesssensors,fromthe
wirelesskeypad,orfromportablependantdevices(suchasthepanicbuttonremote).
1. RequirestheoptionalPOTSmodule,whichisonlyavailableintheUnitedStatesand
Canada.
2. RequirestheoptionalCellularRadioModule.

Go!Control Wireless Security System | User Guide
4Copyright © 2015 Nortek Security & Control LLC
BASIC OPERATION
Followingaregeneraloperationalconcepts
thatyoursystemsupports.Understanding
theseconceptswillhelpyoutouseyour
securitysystemtoitsfullestextent.
Sensor Types/Zones
Thesystem’swirelesssensorshavebeen
assignedtoselected“types”(oftencalled
“zones”).Thesensortypedetermineshow
andwhenthesystemwillreacttoasignal
fromthesensor.Somesensorsarearmed24
hoursaday,othersensorsareonlyarmed
whenthesystemisarmed.
Smoke, Heat, and Freeze
Protection
Ifwirelesssmoke,heatandfreezedetectors
havebeeninstalledinyoursystem,theyare
armed24hours‐a‐day,Theywillsoundan
alarmwhensmokeisdetectedandcan
reportthefirealarmtotheCentralStation.
See"Smoke,HeatandFreezeProtection"on
page19foremergencyplanningand
evacuationinformation.
Burglary Protection
Burglaryprotectionisprovidedbyperimeter
andinteriorsensors.Whenthesystemis
armedintheAwaymode,bothperimeter
andinteriorsensorsarearmedandcan
triggeranalarm.Whenthesystemisarmed
intheStaymode,onlytheperimetersensors
arearmedandcantriggeranalarm.
BotharmingmodesofferanExitDelaythat
allowstimetoexitthepremiseswithout
triggeringthealarm.Uponre‐entry,anEntry
Delayisenabledthatallowsyoutimeto
disarmthesystem.
Youcansetsensorstosoundachimeand/or
avoiceannouncementwhentheyare
triggered.Soyoucanmonitoryourdoors
andwindowswhilethesystemisdisarmed.
Formoredetails,see"BurglaryProtection"
onpage7.
User Codes
Thesysteminstallerhasalready
programmedamasterusercodeforyour
system.Thiscodecanbeusedtocontrolthe
systemaswellasassignandchangethe
otherusercodes.Themasterusercodecan
alsoaccessseveralsystemsetupsettingsin
theUserToolbox.
Alarms
Whenanalarmoccurs,theControlPanel’s
sirenandanexternalsiren(ifinstalled)
soundsforapresettime.Duringalarmsand
afterdisarming,thealarmhistorybutton
displaysallthealarmsthathaveoccurred,
andwhichsensorswereinvolved.Thealarm
historyclearsthenexttimethesystemis
armedorcanbeclearedmanually.
Messages
Yoursecuritysystemsupportsreceiving
messagesfromtheCentralStation.The
messagescanbeaboutsystemupgrades,
additionalservices,specialregionalweather
alerts,etc.
Trouble Alerts
Thesystemmonitorsitselfforabnormal
operatingconditionsandwillalertyouif
troubleisdetected.Troubleconditionscan
bereportedtotheCentralStation.
Wireless Sensors
Yoursecuritysystemcomeswithwireless
sensors.Somesensorsarevisible,others
maybehiddenbydoorjambsorwherethe
sensorismounted.Dependingonyourtype
ofinstallationandhowmanysensorsare
installedwiththeControlPanel,sensorscan
includebutarenotlimitedtothefollowing:
Door/WindowSensor MotionDetector
GlassBreakSensor Smoke/Heat/Freeze
Alarm
COSensor PanicButtonRemote
Keyfob WirelessKeypadand
WirelessTouchScreen
Keypad

System Overview
Copyright © 2015 Nortek Security & Control LLC 5
CONTROL PANEL FEATURES
SeethetablebelowforfulldescriptionsofControlPanelFeatures.
AAlarmSounderandSpeaker Soundsallsystemlocalalarms,voiceprompts,systemsounds,and
audiofor2‐wayvoicecommunicationswiththeCentralStation
BColorDisplaywith
Touchscreen
Showsallsysteminformation,status,programming,andfunctionsas
thekeypad.Taptoswitchbetweentheclock,calendar,andweather
andweatherdisplay.
CMicrophone ForvoicecommunicationwiththeCentralStation
DEmergencyButton/Indicator LightsWHITEwhenenabledforemergencyalarms.FlashesWHITE
duringemergencyalarms
EHomeButton/Indicator SensorStatus
LightsGREENwhenallsensorsareclosed(readytoarm)
Notlitwhenanysensorisopen(notreadytoarm)
ArmingStatus
LightsREDwhensystemisarmed
FlashesREDduringtheEntryDelay
AlarmMemory
FlashesREDduringanalarm
FlashesREDafteranalarmwhilesystemisstillarmed
PowerOutage
FlashesWHITEduringpoweroutage(systemonbatterybackup)
FlashesGREENwhenallsensorsareclosed(readytoarm)
FlashesORANGEwhenanysensorisopen(notreadytoarm)
FlashesREDwhilesystemisarmed

Go!Control Wireless Security System | User Guide
6Copyright © 2015 Nortek Security & Control LLC
MAIN DISPLAY SCREENS
Usethetouchscreentocontrolandoperate
theControlPanel.Thetouchscreenincludes
avarietyofbuttons,indicators,andtextfor
navigationandsystemoperation.
Atthetop‐leftoftheHomescreen,youcan
viewthecurrentsystemstate.Scrollingtext
showinganypendingalerts.Therightsideof
thescreenrevealsavarietyofsystemstatus
icons.
Home Screen
TheHomescreenshowssystemstatuswith
iconstoindicatesystemconditions.Italso
displaysthetimeanddate.TheHomescreen
hasSecurity,Services,SilentControland
DisplayOffbuttons.
TIP: TaptheServicesbuttontogainacessto
featuresforcontrollingZ‐Wavedevices.
IftheZ‐Wavefeaturesarenot
programmed,thisbuttonwillnotappear.
•TaptheHomebuttononthepanel
torevealtheHomescreen.
Security Screen
UsetheSecurityscreentoaccesstheArm,
Menu,andStatusscreens.Thisscreenalso
showsthecurrenttimeanddate.If
messages,alarms,ortroublealertsare
pending,squarebuttonsandindicatesthe
numberofpendingalarmsormessages
Ready to Arm Screen
UsetheReadytoArmscreentoarmthe
securitysysteminStayandAwaymode.You
alsohavetheoptiontoselecttheEntry
DelayandSilentExitcheckboxestoturn
thosefeaturesON.
Menu Screen
UsetheMenuscreentogainaccesstothe
ReadytoArm,Emergency,orToolbox
screen.
Status Screen
UsethecontrolsintheStatusscreentoview
thesystem’scurrentstatusandtoreviewa
scrollinglistofalertsinalogformat.The
date,timeandnatureofanyalertsarelisted
inthedisplayedlog.
•TaptheSilencebuttontostopthe
systemstatusvoiceannouncement.
•Tapthe↑or↓arrowstoscrollthrough
theliststatusmessages.

Copyright © 2015 Nortek Security & Control LLC 7
BURGLARY PROTECTION
Whenyoursystemwassetupbyyourinstaller,wirelesssensorswereplacedtomonitor
specificdoorsandwindows.Theinstallerselectedthesedoorsandwindowsaslikelyplaces
whereanunlawfulintrusionmightoccurandcouldbedetected.Eachsensorwas
programmedtohavethesystemreactinaspecificway.See“InstallerProgrammedOptions”
onpage41forspecificsabouteachsensor.
Somesensortypessuchassmokedetectors,carbonmonoxidedetectors,panicbuttons,etc.
arealwaysactiveandcantriggeranalarmatanytime.Othersensorsonprotecteddoorsand
windowsarepartoftheburglaryprotectionpartofthesystem,andcanbeturnedonoroff.
Turningontheburglaryprotectionpartofthesecuritysystemiscalled“ArmingtheSystem”.
Theburglaryprotectionpartofthesystemcanbearmedintwomodes:StaymodeorAway
mode.
SAMPLE FLOOR PLAN
Refertothefloorplanbelow.Itshowsatypicalresidentialinstallationandthevarioustypesof
wirelesssensorsandtheirfunctions.
AFrontandsidedoorsensorshaveExit/Entrydelay SMKE Smokedetector
BSideandmaingaragedoorsensorshaveExit/Entrydelay CO Carbonmonoxidedetector
CP Controlpanel GB Glassbreaksensor
DW Door/windowsensor PAD Wirelesskeypad
PIR Motiondetector ES Externalsiren

Go!Control Wireless Security System | User Guide
8Copyright © 2015 Nortek Security & Control LLC
SENSOR STATUS
Thesecuritysystemconstantlymonitorsallofthesensorsattachedtotheprotecteddoors
andwindowsinyourhomeorbusiness.TheControlPanelknowsifeachdoororwindowwith
sensorsisopenorclosed.Theopenorclosedconditionoftheprotecteddoorsandwindowsis
calledthesensorstatus.
Formaximumsecurity,allthedoorsandwindowsonyourpremisesshouldbeclosedwhen
youleavethebuilding.Insomecases,suchaswhenusingthesecuritysystemwhenyoustay
athome,youmaywanttoleavesomedoorsorwindowsopen.Thesystemrecognizes
bypassestoresolvetheopendoorsorwindows.See"Bypassing/Un‐BypassingSensors"on
page10.
NOTE: Beforeyoucanarmthesystem,youmustcloseorbypassalldoorsandwindows
withsensors.
CHECKING FOR CLOSED SENSORS
Inmostcases,youwillbearmingthesecuritysystemwithallofthesensor‐protecteddoors
andwindowsclosed.TheControlPanelprovideseasywaystoverifythatallthesensor‐
protecteddoorsandwindowsareclosedbeforearmingthesystem:
•TheHomebuttonlightsgreenwhenallperimetersensorsareclosed.The Home
buttonisnotlitifanyperimetersensorisopen.Openinteriorsensorsdonotchangethis
indication.
•TheSecuritybuttononthedisplay’sHomescreenlightsgreenwhenallperimetersensors
areclosed.TheSecuritybuttonislitorangeifanyperimetersensorisopen.Openinterior
sensorsdonotchangethisindication.
•TheArmbuttononthedisplay’sSecurityscreenandMenuscreenlightsgreenwhenall
perimetersensorsareclosed.Ifanyinteriorsensorsareopen(orwhenanymotion
detectoristriggered),ahouseiconisdisplayedonthestatusbar.TheArmbuttonislit
orangeifanyperimetersensorisopen.

Burglary Protection
Copyright © 2015 Nortek Security & Control LLC 9
VIEWING EACH SENSOR’S STATUS
TheControlPanelwillalsoshowyouwhichsensor‐protecteddoorsandwindowsareopen.
Yourinstallerhasprogrammeddescriptivenamesforeachsensor‐protecteddoorand
window.TheControlPanel’scolordisplaywillshowthenamesofwhichdoorsandwindows
areopen.
•ThetopofthedisplayontheHome,Security,andMenuscreenssensorstatus.See
“SystemStatusIcons”onpage25.
TappingtheStatusbuttonalsodisplaysalistofopensensorsandgeneralsystemstatus
andalerts.
ATheStatusBarshowsthesystemmodeandshowssystemstatusicons.See“SystemStatusIcons”
onpage25.
BTheArmbuttononthesecurityandmenuscreenslightsgreenwhenallperimetersensorsare
closed.TheArmbuttonlightsorangeifanyperimetersensorisopen.
CTheHomebuttonlightsgreenwhenallperimetersensorsareclosed.TheHomebuttonisnotlitif
anyperimetersensorisopen.
DTheicondisplayedshowsthataninteriorsensorisopen.Othericonscanappearhereaswell.See
“SystemStatusIcons”onpage25.
DEALING WITH A SENSOR FALSE ALARM
TheControlPanelreportsalarmconditionsonallsensorswhenarmedbothvisually(onthe
statusbar,andthroughasystemalerticon)andaudibly(throughvoiceandchime
announcements).Therearetimes,thoughrare,thatansensorwillsendanalarmconditionto
theControlPanelwhennoalarmexists.Theconditionsofafalsealarmvarydependingonthe
typeofsensorandhowthatsensorcommunicateswiththeControlPanel.
•PerformaSystem,Sensor,andPanelTesttofindanyfalsealarmconditions.See"System
Test"onpage34.See"SensorTest"onpage35.See"PanelTest"onpage35.

Go!Control Wireless Security System | User Guide
10 Copyright © 2015 Nortek Security & Control LLC
SENSOR BYPASSING
Beforethesystemcanbearmed,all
protecteddoorsandwindowsmustbe
closedorbypassed.Youcanbypassopen
sensorsonprotecteddoorsorwindows
beforearmingthesystem.Whenasensoris
bypassed,thesystemignoresthatthedoor
orwindowisopen.Therearetwotypesof
sensorbypassesavailable:
•Forced
•Manual
Insomecases(suchaswhenusingthe
securitysystemforprotectionwhenstaying
athome)itmaybedesirabletoleavesome
sensor‐protecteddoorsorwindowsopen.
Temporari ly bypassingasensorforthisuseis
calledForceBypassing.
NOTE: Forcebypassesare
automaticallyremovedwhenthe
systemisdisarmed.
Sensorbypassingisalsosometimesused
whenasensorisrequiringservice.Asensor’s
magnetmightbemissing,oranexternal
switchcontactconnectedtoasensormight
befaulty,causingthesensortobedetected
asopenbytheControlPanel.Inthese
conditions,youmayneedtoschedulea
servicecallwithyourqualifiedalarmservice
techniciantorepairorreplacethetroubled
sensor.Ifthesecuritysystemneedstobe
armedbeforethesensorcanbeserviced,
thesensorcanbemanuallybypassedsothe
restofthesystemcanbearmed.Depending
onprogramming,manualbypassescan
remaininplaceuntiltheyaremanually
removed.
NOTE: Bypassedsensorsofferno
protectionandcannotcausean
alarm.Usebypassifyouwantto
armyoursystemwithoneormore
sensorsopenandintentionally
unprotected.
Force Bypass All Sensors
Ifanysensorsareopenwhenthesystemis
disarmed,theArmbuttononthepanelturns
YELLOW.WhenyoutaptheArmbutton,the
systemautomaticallyrevealstheBypass
screenwhichletsyouarmthesystemwhile
forcingittobypassallopensensors.
Toforcebypassallopensensors:
1Ensureasensorisopen,suchasadoor
orwindow.
2AttheSecurityorMenuscreen,tapthe
YELLOWArmbutton.
3AttheBypassscreen,tapBypassAll.
Thisforcesthesystemtobypassallof
theopensensorsinthelist,including
anyopeninteriorsensors.
4AttheEnterCodescreen,enteravalid
usercodetobypassthesensor.
NOTE: TheQuickBypassfeaturecan
alsobeconfiguredbytheinstaller.
Fordetails,refertotheControl
Panel’sInstallation&
ProgrammingGuide.
5AttheReadytoArm(SensorsBypassed)
screen,tapStayorAwaymode.
Later,whenyoudisarmthesystem,the
bypassedsensorsarereturnedtotheir
normalstate.
Bypassing/Un-Bypassing
Sensors
Toaddorremovesensorsonthesystem’s
bypasslist:
1AttheHomescreen,tapMenu.
2AttheMenuscreen,tapToolbox.
3Enteravalidusercodetogainaccessto
theToolbox.
4AttheToolbox(1of3)screen,tap
BypassedSensors.
5AttheBypassedSensorsscreen,choose
oneoftheseoptions:
•Addasensortothebypassedlist.
TaptheBLUEbuttonthat
correspondstothedesiredsensor.
WhenthebuttonturnsYELLOW,the
systemwillbypassthesensor.

Burglary Protection
Copyright © 2015 Nortek Security & Control LLC 11
•ViewOnlyBypassedSensors.Place
acheckmarkintheShowBypassed
Onlybox.
•Removeasensorfromthebypassed
list.TaptheYELLOWbuttonthat
correspondstothedesiredsensor.
ThebuttonturnsBLUEwhenitisno
longeronthebypassedlist.
6Whenfinished,tapBack.
STAY MODE
UseStaymodetopartiallyarmthesystem
whenindividualswillbeoccupyingthe
premises.Thisarmsonlythesensor‐
protectedperimeterdoorsandwindows.It
leavesinteriormotionsensorsorother
interiordoorsunarmed.Inahomesetting,
Staymodeistypicallyusedduringthe
eveninghourswhenoccupantsarenolonger
expectedtoleaveorenterthepremises.This
allowsoccupantstomoveaboutthe
premiseswithouttriggeringtheburglary
alarm.Becausealltheinteriorburglary
protectionisOFF,analarmwouldonlybe
triggeredwhenasensor‐protected
perimeterdoororwindowisopened.
Entry Delay in Stay Mode
Certainsensors,suchasadoor,canbe
configuredbyyourinstallertouseadelay
timerbeforetriggeringanalarm.This
providesawayforanauthorizedperson
returningtoenterusingapredetermined
dooranddisarmthesystembeforeanalarm
istriggered.
ToarmthesystemusinganEntryDelay:
1AttheSecurityorMenuscreen,tapthe
Armbutton.
2AttheReadytoArmscreen,placea
checkmarkintheEntryDelaybox.Thisis
thedefaultsetting.
NOTE: Ifyouremovethecheckmark
fromtheEntryDelaybox,analarm
willbetriggeredwhenthesensor
isopenedwhilethesystemis
armedinStaymode.
3TapStaytoarmthesystem
NOTE: Whenre‐enteringthepremises,
theusermustenterthroughthe
door(s)programmedtousethe
entrydelaytimer.Thisgivesthe
useraspecifiedamountoftimeto
disarmthesystem.Ifthesystemis
notdisarmedintime,analarmis
triggered.

Go!Control Wireless Security System | User Guide
12 Copyright © 2015 Nortek Security & Control LLC
Quick Exit in Stay Mode
Aprogrammableoption,calledQuickExit
maybedisplayedontheSecurityscreen
whilethesystemisarmedinStaymode.Tap
theQuickExitbuttontostartatimerto
allowsomeonetoexitorenterthrougha
sensor‐protecteddoorprogrammedfor
delaywithouthavingtodisarmtheentire
system.Whenthedelaytimerrunsout,the
systemreturnstothenormalStaymode.
TheQuickExitoptioncanbeturnedonoroff
byyourinstaller,see"InstallerProgrammed
Options"onpage41tounderstandthe
optionsthathavebeenprogrammedfor
yoursystem.
SILENT CONTROL IN STAY
MODE
Threeoptionsforsilencingthebeepsand
announcementsareavailablewhenarming
ordisarmingthesysteminStayMode.
•AttheHomeorSecurityscreen,tapthe
SilentControlbutton.
•AttheReadytoArmscreen,selectthe
SilentExitcheckbox.
•OntheExitDelayscreen,tapSilence.
Selectinganyoftheseoptionssilencesthe
ControlPanelbeepsandannouncements,
andwhenarming,selectingtheoption
doublesthelengthoftheExitDelay.
Arming to Stay Mode
UseStayModetoarmthesystemwhen
anyoneisathome.StayModenormallyhas
anEntryDelaysoauserwithausercodecan
re‐enterwithoutcausinganalarm.
1Closeallprotectedperimeterdoorsand
windowsbeforearming.
2Verifythatthe buttonontheControl
PanelislitGREENindicatingthatthe
systemisreadytoarm.TheSecurityand
ArmbuttonsonthedisplayisGREEN
whenallsensorsareclosed.
NOTE: Ifyouwanttoarmthesystem
quietlywithoutsoundingany
announcements,tap before
performingthesesteps:
•AtReadytoArmscreen,placea
checkmarkintheSilentExitbox.
Or
•DuringexitdelaytapSilence.
3AttheSecurityorMenuscreen,tap
Arm.
NOTE: Ifthereareanyopenperimeter
doororwindowsensors,the
Bypassscreenappears.Closeall
thesensorsdisplayedortap
BypassAlltoforcebypassthe
displayedsensors.
NOTE: Bypassedsensorsdonottrigger
analarm.(Tobypasssensors,enter
ausercodeunlesstheinstallerhas
setthesystemforQuickBypass).
4OntheReadytoArmscreen,selectthe
EntryDelaycheckboxwhenarmingthe
systeminStaymode.
Ifnooneisexpectedtore‐enter,the
systemcanbearmedwithoutanEntry
Delay.Allperimeterdoorswilltriggerthe
alarminstantly.Toarmwithallexit/
entryperimeterdoorsasinstant,remove
thecheckmarkfromtheEntryDelaybox.
5TapStaytoarmthesystem.
NOTE: Toarmthesystem,youmay
needtoenterausercodeifyour
installerhasturnedoffthe
system’sQuickArmingfeature.
6ThesystemwillarmandshowstheExit
Delaycountingdown.WhentheExit
Delayexpires,thesystemisfullyarmed
intheStaymode.

Burglary Protection
Copyright © 2015 Nortek Security & Control LLC 13
AWAY MODE
Awaymodeisforarmingthesystemwhen
everyoneisleavingthepremises.Away
modearmsallsensor‐protectedperimeter
doorsandwindows,interiormotionsensors,
interiorglassbreaksensors,andanyother
sensor‐protectedinteriordoors.The
premisesmustbeunoccupiedwhilethe
systemisarmed.Awaymodeistypically
usedforarmingthesystemduringthe
daytimehoursinaresidentiallocation,and
non‐businesshoursinacommerciallocation.
WhenthesystemisarmedinAwaymode,
youcannotmoveaboutthepremises
withouttriggeringtheburglaryalarm(ifthe
systemisinstalledwithinteriormotion
detectors).Analarmalsooccursifany
sensor‐protecteddoororwindowisopened
orglassbreakageisdetected(ifglass
breakagedetectorsareinstalledinyour
system).
Exit and Entry Delays in Away
mode
Certainsensors,suchasadoor,canbesetup
byyourinstallertohaveadelaybefore
triggeringanalarm.Thisprovidesawayfor
anauthorizedpersontoexitandreenterthe
premiseswithouttriggeringanalarm.
•ExitDelayallowstimetoleaveafter
armingthesystem.
•EntryDelayallowstimetoenterand
disarmthesystembeforeanalarmis
triggered.
Whenarmingthesystemin
Awaymode,anEntryDelay
checkboxisshownonthe
Armingscreen.Bydefault,
thisoptionischecked,sothe
programmeddelaydoorsallowtimefor
disarmingthesystemafterthedooris
opened.Ifyouun‐checkthisbox,the
delayedalarmtriggerisremovedfromall
sensor‐protecteddoorsprogrammedfor
delay.Thoseentrancesinstantlytriggeran
alarmiftheyareopenedinAwaymode.
NOTE: WiththeEntryDelaydisabled,
youmustremotelydisarmthe
systemwithawirelesskeyfob
beforeentering.
Exit Delay Restart
TheExitDelayRestartoptionextendsthe
ExitDelayonetimeifyouneedtore‐enter
thepremises.WiththeExitDelayRestart
option,whenyoure‐enterthepremises
afteryouhaveleft,butbeforetheExitDelay
timerexpires,willrestarttheExitDelay
timer,givingyouthefulllengthoftimeto
leaveagain.
TIP: TheExitDelayRestartoptiononlyworks
once,eachtimethesystemisarmed.
Silent Control in Away Mode
Threeoptionsforsilencingthebeepsand
announcementsareavailablewhenarming
ordisarmingthesysteminAwaymode.
•OntheControlPanel’sHomeand
Securityscreens,aSilentControlbutton
isdisplayed.
•OntheArmingscreen,aSilentExitcheck
boxisdisplayed.
•OntheExitDelayscreen,aSilence
buttonisdisplayed.
Selectinganyoftheseoptionssilencesthe
ControlPanelbeepsandannouncements,
andwhenarming,selectingSilentControl
doublesthelengthoftheExitDelay.

Go!Control Wireless Security System | User Guide
14 Copyright © 2015 Nortek Security & Control LLC
Quick Exit in Away Mode
AprogrammableoptioncalledQuickExit
maybedisplayedontheSecurityscreen
whilethesystemisarmedintheAway
mode.TappingtheQuickExitbuttonstartsa
timertoallowsomeonetoexitorenter
throughasensor‐protecteddoor
programmedfordelaywithouthavingto
disarmtheentiresystem.Whenthedelay
timerrunsout,thesystemreturnstothe
normalAwaymode.
TIP: Ifinteriorsensorsareinstalledinthe
systemincertainareas,donotviolate
thosesensorswhenusingtheQuickExit
featureinAwaymode.
Auto Stay Mode
Thesystemmayhavebeenprogrammedby
theinstallerforAutoStaymode.Ifthis
optionisonandthesystemisarmedinAway
mode,ifanexit/entrydelaysensorisnot
triggeredbeforetheExitDelayexpires(no
oneleftthepremises),thesystem
automaticallyarmsinStaymodeinsteadof
Awaymode.
NOTE: Quickoptionscanbeturnedon
oroffbyyourinstaller.Referto
"InstallerProgrammedOptions"on
page41,toseewhichoptionshave
beensetforyoursystem.
Arming to Away Mode
UsetheAwaymodetoarmthesystemwhen
everyonewillbeleavingthehome.The
AwaymodenormallyhasanEntryDelayso
someonewithausercodecanre‐enter
withoutcausinganalarm.Interiorand
perimetersensorsarearmedintheAway
mode.
1Closeallsensor‐protecteddoorsand
windowsbeforearming.
2Verifythatthe buttonontheControl
Panelislitgreen,indicatingthatthe
systemisreadytoarm.TheSecurity
buttonandArmbuttononthedisplay
willalsobegreenwhenallperimeter
sensorsareclosed.Iftheiconis
displayedonthestatusbar,aninterior
sensorisopen,besuretocloseor
manuallybypasstheinteriorsensorsor
analarmwilloccur.
3Toarmthesystemquietlywithout
soundinganyannouncements,tapthe
buttonbeforeperformingthenext
steps:
•AttheArmingscreenselectthe
SilentExitcheckbox
Or
•DuringtheExitDelay,tapSilence
4AttheSecurityscreen,ortheMenu
screen,tapArm.
Ifthereareanyopenperimeterdooror
windowsensors,theBypassscreen
appears.Closeallthesensorsdisplayed
ortapBypassAlltoforcebypassthe
displayedsensors.
NOTE: Bypassedsensorsdonottrigger
analarm.
Tobypasssensors,enterausercode
unlesstheinstallerhassetthesystemfor
QuickBypass.
5OntheArmingscreen,theEntryDelay
checkboxoptioncanbeusedwithAway
mode.
•Thesystemcanbearmedwithoutan
EntryDelay.Allperimeterdoorstrigger
thealarminstantly.Thesystemhastobe
disarmedwithawirelesskeyfob.Toarm
withallexit/entryperimeterdoorsas
instant,un‐checktheEntryDelayoption
button.

Burglary Protection
Copyright © 2015 Nortek Security & Control LLC 15
6TapAway.
Toarmthesystem,enterausercodeif
yourinstallerhasturnedoffthesystem’s
QuickArmingfeature.
7ThesystemarmsandshowstheExit
Delaycountingdown.WhentheExit
Delayexpires,thesystemisfullyarmed
intheAwaymode.
NOTE: Whenthesystemisarmedin
theAwaymode,beepssound
duringtheExitDelay(fasterbeeps
duringthelast10seconds).
DISARMING THE SYSTEM
TostoptheControlPanelfromtriggering
burglaryalarms,thesystemneedstobe
disarmed.Disarmingturnsofftheburglary
detectionpartofthesystemforsensorsthat
arenot24‐hoursensors.Disarmingalso
stopsanytypeofalarminprocess.
DisarmthesystemfromStaymodebefore
exitingthepremises.Thesystemshouldbe
disarmedfromAwaymodebeforeorwhile
enteringthepremises.Whendisarmingfrom
theControlPanelorwirelesskeypad,entera
validusercode.Awirelesskeyfobcanalso
beusedtodisarmthesystem.Enteringa
usercodeisnotrequiredwhendisarming
withawirelesskeyfob.
AnimportantfeatureoftheControlPanelis
itsabilitytowarnyouifanalarmhas
occurredwhileyouwereaway.Ifanalarm
wastriggeredwhilethesystemwasarmed,
thealarmsirenrunsforapresetlengthof
timethenstops.Whenyouentertodisarm
thesystem,insteadofsoundingthenormal
EntryDelaybeeps,theControlPanelsounds
repeatedfastbeepstowarnyouthatan
alarmhasoccurredwhileyouwereaway.
Whenyouenteryourhometo
disarmthesystem,ifyouhear
fastrepeatedbeepsinsteadof
thenormalentrydelaybeeps,
UseExtremeCaution!Anintrudermay
stillbepresentinsidethebuilding!Wait
outsideanduseaCellPhonetocalllaw
enforcementforassistance.
Disarming from Stay Mode
DisarmthesystemfromStaymodebefore
exitingthepremises.
1AttheHomescreen,tap forSilent
Control.
2AttheSecurityscreenortheMenu
screen,tapDisarm.Thisactiondisplays
theDisarmCodescreen.
3Theleftsideofthescreenshowsany
eventsthathaveoccurredwhilethe
systemwasarmed.
4Enteravalidusercodetodisarmthe
system.
•Incaseyoutapthewrongkey,the
buttonerasestheentireentry.
•Tapifyoudecidetonotdisarm
thesystematthistime.

Go!Control Wireless Security System | User Guide
16 Copyright © 2015 Nortek Security & Control LLC
Disarming from Away Mode
ThesystemshouldbedisarmedfromAway
modewhileenteringthepremises.
1Enterthepremisesthroughadesignated
EntryDelaysensor‐protecteddoor.
2TheDisarmCodescreendisplaysonthe
ControlPanelandtheEntryDelaybeeps
sound.Theleftsideofthescreenshows
eventsthathaveoccurredwhilethe
systemwasarmed.
3Enteravalidusercodetodisarmthe
system.
•Incaseyoutapthewrongkey,the
buttonerasestheentireentry.
IF A BURGLARY ALARM
OCCURS
Ifanarmedsensoristrippedwhilethe
systemisarmedintheStayorAwaymode,
analarmoccursandthesirensounds.
DelayedsensorsstarttheEntryDelayto
allowtimetodisarmthesystem.Instant
sensorstriggerthealarmrightaway.Most
sensorstriggerthealarmsiren,some
sensorsmaybesettotriggerasilentalarm
withoutsoundingthesiren.
Burglary Alarm Siren
Ifthereisaburglaryalarmtrippedwhilethe
systemisarmed,theControlPanelsounds
thealarmsirenforapresettime(see
"InstallerProgrammedOptions"onpage41).
Afterthetimeexpires,thesirenwillstop
sounding.
Thesystemlimitsthenumberoftimesa
sensorcanre‐triggeranalarmwhilethe
systemisarmed.Thesettingisonetosix
timespersensor,perarmingperiod(see
"InstallerProgrammedOptions"onpage41).
Alarm Memory
Ifanalarmhasoccurredwhilethesystem
wasarmed,theDisarmscreenshowsthe
timeanddateofthealarmandthesensor(s)
thattriggeredthealarm.
Afterthesystemisdisarmed,theAlarm
Memoryscreenappears.TheAlarmMemory
screenshowsthesensor(s)thathavecaused
thealarm.Ifmorethanonesensorhasbeen
triggered,thedisplayshowstheorderin
whichthealarmsoccurred.
Thealarmmemoryautomaticallyclearsthe
nexttimethesystemisarmed.Youcanalso
checktheClearAlarmHistorybuttonand
tapOktomanuallyclearthealarmmemory
(24‐hourfireandCOsensorsthatarestill
violatedremaininalarmmemory).

Burglary Protection
Copyright © 2015 Nortek Security & Control LLC 17
Optional 2-Way Voice
Communications
2‐wayvoicecommunicationsprovidesa
methodforalarmverificationandcan
provideemergencyassistance.TheControl
Panelcontainsabuilt‐inmicrophonethat
canmonitorsoundsaroundtheareaofthe
ControlPanel.Thebuilt‐inmicrophoneand
speakerallows2‐wayvoicecommunications
withaCentralStationoperatorafteran
alarm.Theoperatorcanconversewith
peopleinthepremisesthroughtheControl
Panel’sspeakerandmicrophone.
Yourinstallercansetthesystemtouse2‐
wayvoicecommunicationsafteranalarm
and/orafterapanicalarmistriggered.
NOTE: Ifapanicalarmorsensorisset
forasilentalarm,theoperatorcan
onlylistenandnotbeabletotalk.
Thisisforyourprotection.
KEY FOB: ARMING AND
DISARMING
Yoursystemmaybeequippedwithoneor
morewirelesskeyfobs.Uptoeightkeyfobs
canbeusedtocontrolthesystemremotely.
Eachkeyfobhasfourbuttonsandcan
performfivefunctions.Ausercodeisnot
requiredwhenarmingordisarmingthe
systemwithawirelesskeyfob.
Thereareseveralkeyfoboptionsthatcanbe
setbytheinstaller.See"Installer
ProgrammedOptions"onpage41.
Arm the Keyfob
Stay Mode
ToarmthesystemtoStaymodeusingakey
fob,taptheStaybutton.
NOTE: Dependingonsetupoptions,if
thereareopenperimeterdoorsor
windows,thesystemmaynot
allowarmingtoStaymodewitha
wirelesskeyfob.See"Installer
ProgrammedOptions"onpage41.
Away Mode
ToarmthesystemtoAwaymodeusingakey
fob,tapthebutton.
NOTE: Dependingonsetupoptions,if
thereareopenperimeterdoorsor
windows,thesystemmaynot
allowarmingtoAwaymodewitha
wirelesskeyfob.See“Installer
ProgrammedOptions”onpage41.
Disarm the Keyfob
Usingakeyfobtodisarmthesystemfrom
StayorAwaymode,taptheDisarm
button.
NOTE: Touseyourkeyfobtodisarm
yoursystem,thisoptionmust
alreadybeenabledbyyour
installer.
Activate the Emergency Alarm
Totriggeranemergencyalarmusingakey
fob,taptheAwaybuttonandDisarm
buttonatthesametimefor5seconds.
NOTE: Ifanemergencyalarmis
triggeredbyakeyfob,itcannotbe
stoppedusingthekeyfobDisarm
button.Thealarmmustbe
canceledattheControlPanel.
Activate the Auxiliary Output
TotriggertheControlPanel’sauxiliary
output,taptheAuxiliarybutton.
IfyouusetheAuxiliarybutton,theauxiliary
outputcontrolsthe_________________...

Go!Control Wireless Security System | User Guide
18 Copyright © 2015 Nortek Security & Control LLC
WIRELESS KEYPAD: ARMING
AND DISARMING
Yoursystemmaybeequippedwithoneor
morewirelesskeypads.Uptofour(4)
wirelesskeypadscanbeusedtocontrolthe
systemremotelyfromthemainControl
Panel.
Twotypesofwirelesskeypadsareavailable.
Awirelesskeypadwithoutascreen,andthe
wirelesstouchscreenkeypad.
Thewirelesstouchscreenkeypadoperates
virtuallythesameastheControlPanel.Each
standardwirelesskeypadhasbuttonsfor
enteringusercodes,StayandAwaymode
buttons,andFireandPoliceemergency
buttons.
ChecktheInstallerSetOptionssectioninthis
guidetoverifywhich24‐hourFireandPolice
emergencybuttonshavebeenenabledby
theinstaller.
Arm the Keypad
Stay Mode
ToarmthesystemtoStaymodeusinga
wirelesskeypad:
1AttheHomescreen,tapSecurity>Arm.
2Enteravalidusercode.
3TaptheStaybutton.
4IfQuickArminghasbeenprogrammed
byyourinstaller,justtaptheStay
button.
Ifthereareopenperimeterdoorsor
windows,thesystemdoesnotallowArming
toStaymodewithawirelesskeypad.All
opensensorsmustbebypassedatthe
ControlPanelfirst.
Away Mode
ToarmthesystemtoAwaymodeusinga
wirelesskeypad:
1AttheHomescreen,tapSecurity>Arm.
2Enteravalidusercode.
3TaptheAwaybutton.
4IfQuickArminghasbeenprogrammed
byyourinstaller,justtaptheAway
button
NOTE: Ifthereareopenperimeter
doorsorwindows,thesystemdoes
notpermityoutouseaWireless
KeypadtoarmthesysteminAway
mode.Allopensensor‐protected
doorsandwindowsmusteitherbe
closedorbypassedattheControl
Panelbeforearmingwitha
wirelesskeypad.
Disarm the Keypad
TodisarmthesystemfromStayorAway
mode,enterausercode.
Activate a Fire Emergency
Totriggeraemergencyfirealarmusinga
wirelesskeypad,taptheFirebuttonfortwo
(2)seconds.
NOTE: Tousewirelesskeypadtotrigger
afirealarm,thisoptionmust
alreadybeenabledbyyour
installer.
Activate a Police Emergency
Totriggeraemergencypolicealarmusinga
wirelesskeypad,tapthePolicebuttonfor
two(2)seconds.
NOTE: Tousewirelesskeypadtotrigger
apolicealarm,thisoptionmust
alreadybeenabledbyyour
installer.
Other manuals for Go!Control Panel