3Com Token Ring User manual

Token Ring
Network Interface Card
Getting Started Guide
Part No. 1.024.1317-00

®
http://www.3com.com/
Token Ring
Network Interface Card
Getting Started Guide
Part No. 1.024.1317-00

3Com Corporation
5400 Bayfront Plaza
Santa Clara, California
95052-8145
Copyright © 1999, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced
in any form or by any means or used to make any derivative work (such as translation, transformation, or
adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time
to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty of any kind, either implied or expressed,
including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
3Com may make improvements or changes in the product(s) and/or the program(s) described in this
documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this documentation and the software described herein are
provided to you subject to the following:
United States Government Legend: All technical data and computer software is commercial in nature and
developed solely at private expense. Software is delivered as Commercial Computer Software as defined in
DFARS 252.227-7014 (June 1995) or as a commercial item as defined in FAR 2.101(a) and as such is provided
with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is
provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14
(June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided
on any licensed program or documentation contained in, or delivered to you in conjunction with, this
User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may
not be registered in other countries.
3Com and the 3Com logo are trademarks of 3Com Corporation.
Other brand and product names may be registered trademarks or trademarks of their respective holders.
YEAR 2000 INFORMATION:
For information on Year 2000 compliance and 3Com products, visit the 3Com Year 2000 web page:
http://www.3Com.com/products/yr2000.html

CONTENTS
1OVERVIEW
Contacting 3Com................................................................................... 1-1
Document Conventions.......................................................................... 1-2
Product Description ................................................................................ 1-3
Product Compatibility ............................................................................. 1-3
2INSTALLATION
Installation Tools..................................................................................... 2-1
Installation Procedure ............................................................................. 2-1
3NETWORK INTERFACE CARD CABLING
Physical Interfaces .................................................................................. 3-1
Accessing the User Interface................................................................... 3-2
ATECHNICAL SPECIFICATIONS
Technical Specifications
Certification ...................................................................................... A-1
Regulatory Compliance Statements ................................................... A-1
United States ...............................................................................A-1
FCC Part 15 Compliance Statement ............................................. A-1
Interface Specifications...................................................................... A-2
Serial Port (RS-232 CH1 and CH2)................................................ A-2
Token Ring (STP Connector) ......................................................... A-2
Token Ring (UTP Connector)......................................................... A-3
Current Draw .................................................................................... A-4
Environment...................................................................................... A-4
Shipping and Storage................................................................... A-4
Operating .................................................................................... A-4
Physical Dimensions .......................................................................... A-4

1OVERVIEW
This chapter provides an overview of:
■Contacting 3Com
■Document conventions
■Product description
■Product compatibility
Contacting 3Com Call the appropriate toll free number listed below for technical support.
For European countries that do not have a toll free number listed,
call +31 30 602 9900.
Country Toll Free Number Country Toll Free Number
Austria 06 607468 Netherlands 0800 0227788
Belgium 0800 71429 Norway 800 11376
Canada 1800 2318770 Poland 00800 3111206
Denmark 800 17309 Portugal 0800 831416
Finland 0800 113153 South Africa 0800 995014
France 0800 917959 Spain 900 983125
Germany 0800 1821502 Sweden 020 795482
Hungary 00800 12813 Switzerland 0800 553072
Ireland 1800 553117 UK 0800 966197
Israel 0800 9453794 United States 1800 2318770
Italy 1678 79489 All Other Locations
(Outside Europe)
1847 7976600

1-2 CHAPTER 1: OVERVIEW
Refer to the Total Control Hub Documentation CD-ROM for more
information regarding product warranty.
For information about Customer Service, including support, training,
contracts, and documentation, visit our website at
http://totalservice.3com.com
Document
Conventions
These tables list conventions used throughout this guide.
Icon Notice Type Description
Information note Information that contains important features or
instructions.
Caution Information to alert you to potential damage to a
program, system, or device.
Warning Information to alert you to potential personal injury
or fatality. May also alert you to potential electrical
hazard.
ESD Information to alert you to take proper grounding
precautions before handling a product.
Convention Description
Text represented as a
screen display This typeface represents displays that appear on your
terminal screen, for example:
Netlogin:
Text represented as
commands This typeface represents commands that you enter for
example:
setenv TCMHOME directory
This guide always gives the full form of a command in
uppercase and lowercase letters. However, you can
abbreviate commands by entering only the uppercase letters
and the appropriate value. Commands are not case-sensitive.
Text represented as
menu or sub-menu
names.
This typeface represents all menu and sub-menu names
within procedures, for example:
On the File menu, click New.

Product Description 1-3
Product
Description
The Token Ring NIC provides a Token Ring interface between a particular
NAC in the 3Com Total Control chassis and your network.
This NIC features one IEEE 802.5 compliant Token Ring interface capable
of data transfer rates of 4 or 16 Mbps. Type 1 (STP) and Type 3 (UTP)
physical ports are available for this interface. In addition, this NIC also
features a RS–232 user interface console port capable of data transfer
rates up to 57.6 Kbps.
Product
Compatibility
The Token Ring NIC is compatible with the NETServer, NetServer PRI and
the 486 Network Management Card (NMC) NAC.

2INSTALLATION
This chapter contains the Token Ring Network Interface Card (NIC)
installation information.
Installation Tools To install this NIC in the Total Control chassis, you need a #2 Phillips and
flat-head screwdriver.
Installation
Procedure
To install this NIC:
ESD: To reduce the risk of electrostatic discharge (ESD), take proper
grounding precautions before handling the NIC.
Install the NIC with or without power applied to the chassis.
1Configure the NIC via the DIP switches.
O N
12 3 4

2-2 CHAPTER 2: INSTALLATION
2Select a slot at the rear of the Total Control chassis for installing the NIC.
Install this NIC in slot(s): 1–17
For managed chassis, slot 17 is reserved for the Network Management
Card (NMC) NIC.
DIP Switch Number Function
1■OFF: Unshielded Twisted Pair (UTP) Token Ring cable
used
■ON: Shielded Twisted Pair (STP) Token Ring cable used
2■Off: 4 Mbps Token Ring speed connection
■ON: 16 Mbps Token Ring speed connection
3■Off: Token Ring NIC installed behind an NMC NAC
(slot 17 only)
■ON: Token Ring NIC installed behind any other NAC
(Slot 1–16)
4■OFF: Reserved

Installation Procedure 2-3
3Use a #2 Phillips screwdriver to remove the safety panel covering this slot.
4Insert the NIC between the slot’s upper and lower card guides.

2-4 CHAPTER 2: INSTALLATION
5Slide the NIC into the chassis, until the front of the NIC is flush with the
chassis.
6Use a flat-head screwdriver to tighten the screws on the front panel.
7Cover any unused chassis slots with safety panels.
8Install the Network Application Card (NAC) corresponding to this NIC.
Refer to the NAC’s Getting Started Guide for more information.

3NETWORK INTERFACE CARD
CABLING
This chapter provides information about the physical interfaces of the
Token Ring Network Interface Card (NIC) and instructions for accessing
the corresponding Network Application Card (NAC) through the user
interface (UI).
Physical Interfaces The Token Ring NIC has the following physical interfaces:
Callout Number Interface Description
1CH1: RJ-45 RS–232 DTE Port
Used to access the corresponding NAC’s UI
console. This port’s speed is determined by
DIP switch setting on the NAC.
2CH2: RJ-45 RS–232 DTE Port
Used as a dedicated SLIP port when behind
the Network Management Card (NMC). It
is reserved when behind any other NAC.
3STP: DB-9 IBM Type 1 Token Ring port.
4UTP: RJ-45 IBM Type 3 Token Ring port.
TOKEN
RING NIC
RS-232
RS-232
TOKEN
RING
TOKEN
RING
C
H
1
C
H
2
U
T
P
S
T
P
2
3
1
4

3-2 CHAPTER 3: NETWORK INTERFACE CARD CABLING
Accessing the User
Interface
To access the UI of the corresponding NAC, connect the following cables
to the NIC’s console port.
Callout Number Description
1RJ-45 connector to NIC’s console port
2DB-25 male connector to modem for remote operations
3DB-25 female-to-female null modem adapter to PC or
terminal COM port
TOKEN
RING NIC
RS-232
RS-232
TOKEN
RING
TOKEN
RING
C
H
1
C
H
2
U
T
P
S
T
P

ATECHNICAL SPECIFICATIONS
Technical
Specifications
Certification
Regulatory
Compliance
Statements
United States
FCC Part 15 Compliance Statement
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
EMI/RFI ■FCC 15A
■EN55022A
■VCCI
■AUSTEL
■IEC 1000-3-2 Fluctuating Harmonic Flicker
■IEC 1000-4-2 ESD
■IEC 1000-4-3 RF Immunity
■IEC 1000-4-4 Electrical Fast Transcients
■IEC 1000 4-5 Lightning Surge
Safety ■UL 1950
■C-UL
■EN 60950

A-2 APPENDIX A: TECHNICAL SPECIFICATIONS
to cause harmful interference in which case the user will be required to
correct the interference at their own expense.
Interface
Specifications
Serial Port (RS-232 CH1 and CH2)
RS-232 CH1 and CH2 Cable Specifications
Token Ring (STP Connector)
Electrical Specification: RS-232, 8-position modular jack
(EIA/TIA-232-E Standard)
Connector: Modular Jack:
Stewart 88-360808 or equivalent
Configuration: Data Terminal Equipment (DTE)
Transmission Method: Unbalanced RS-232
Transmission Rate: 57.6 Kbps maximum
Wire Type: Belden 9538 or equivalent, 8 conductor, shielded
Maximum Cable Distance: 50 Feet, 15 Meters
Nominal Direct Current
Resistance:
Center Conductor:
■24 gage (7strand 32 gage)
■.61 millimeter diameter
■23.7 ohms/1000 feet
■77.8 ohms/kilometer
Shield:
■15.5 ohms/1000 feet
■50.9 ohms/kilometer
Nominal Outside Diameter: .265 inch; 6.73 millimeter
Capacitace Between
Conductors:
30 picofarads/feet; 98 picofarads/meter
Cabling: 8-position modular jack to DB-25 (IBM AT pin-out.
Electrical Specification: IEEE 802.5
Connector: DB-9, AMP 747844-3
Accessing Scheme: Token Passing
Topology: Star Wired Ring
Maximum Nodes for
Physical Network:
250

Technical Specifications A-3
STP Connector Cable Specifications
Token Ring (UTP Connector)
Transmission Medium: Type 1-Individual Shielded Pair
Network Lobe Distance: 100 meters (328 feet) suggested maximum
Data Transfer Rate: 4 or 16 Mbps
Wire Type: Belden 96888 or equivalent, 4 conductors in two
individually shielded pairs, copper braid shield overall
Maximum Cable Distance: 328 feet, 100 meters
Nominal Direct Current
Resistance:
■22 gage solid copper
■.0255 inches diameter
■16 ohms/1000 feet
■52.5 ohms/kilometer
Nominal Outside Diameter: .310 inch x .455 inch
Nominal Impedance: 150 ohms
Nominal Velocity of
Propagation:
■8.5 picofarads/foot
■27.9 picofards/meter
Electrical Specification: IEEE 802.5
Connector: 8-position modular jack, Stewart 88-360808 or
equivalent
Accessing Scheme: Token Passing
Topology: Star Wired Ring
Maximum Nodes for
Physical Network:
72
Transmission Medium: Type 3-unshielded Twisted Pair
Network Lobe Distance: 100 meters (328 feet) suggested maximum, Level 4
Data Transfer Rate: 4 or 16 Mbps

A-4 APPENDIX A: TECHNICAL SPECIFICATIONS
UTP Connector Cable Specifications
Current Draw
Environment Shipping and Storage
Operating
Physical Dimensions
Wire Type: Belden 1154A or equivalent, 8 conductors in 4 twisted
pairs
Maximum Cable
Distance:
328 feet, 100 meters
Nominal Direct Current
Resistance:
■24 gage solid copper
■.020 inches diameter
■25.7 ohms/1000 feet
■84.3 ohms/kilometer
Nominal Outside
Diameter:
.185
Nominal Impedance: 105 ohms
Nominal Velocity of
Propagation:
60%
Nominal Capacitance
Between Conductors:
■15.0 picofarads/foot
■49.2 picofards/meter
Cabling: 8-position modular plug
Voltage Current Draw (Typical) Current Draw (Maximum)
+5 VDC 1.2 A 1.5 A
+12 VDC 3 mA 50 mA
Temperature: -25 to 75°C, -13 to 167°F
Relative Humidity: 0 to 100%, Non-condensing
Temperature 0 to 40°C, 32 to 104°F
Relative Humidity: 0 to 95%, Non-condensing
Inches Centimeters
Length: 5.30 13.46
Width: .79 2.00
Height: 6.90 17.53

3Com Corporation
5400 Bayfront Plaza
P.O. Box 58145
Santa Clara, CA
95052-8145
©1999
3Com Corporation
All rights reserved
Printed in the U.S.A.
Part No. 1.024.1317-00
Table of contents
Other 3Com Computer Hardware manuals

3Com
3Com Megahertz 10 User manual

3Com
3Com 3CCFE575CT Manual

3Com
3Com 3CCFE575CT User manual

3Com
3Com 3CRWE62092A User manual

3Com
3Com ETHERLINK III User manual

3Com
3Com WL-305 User manual

3Com
3Com 3CRWB6096 User manual

3Com
3Com SuperStack II User manual

3Com
3Com 3CRWB6096 User manual

3Com
3Com 3CCFEM556 User manual

3Com
3Com 3CRSHPW796 User manual

3Com
3Com 35 series User manual

3Com
3Com 3CCFE575CT User manual

3Com
3Com 3CRSHPW196 User manual

3Com
3Com PC Card User manual

3Com
3Com 3CRGPC10075 Reference guide

3Com
3Com OfficeConnect 3CRWE154A72 User manual

3Com
3Com 3CRPAG175B User manual

3Com
3Com EtherLink 3C905C-TX-M User manual

3Com
3Com FEM656C User manual