3M 8212 User manual

1
8212
Particulate Respirator N95
3M recommended for welding, brazing, metal pouring and cutting
User Instructions
IMPORTANT: Keep these User Instructions for reference.
98-0060-0145-1/3
XX-XXXX-XXXX-X
7/22/2022

2
This respirator helps protect against certain particles. Misuse may result in sickness or death. For correct
use, consult supervisor and these User Instructions, or call 3M at 1-800-247-3941 in U.S.A., or 1-800-267-
4414 in Canada.
This product contains a small portion of exposed aluminium. It may present a risk in an explosion protected
area or any area where sparks created by contact of the aluminium with rusty iron might cause a hazard.
IMPORTANT
Before use, wearer must read and understand these User Instructions. Keep these User Instructions for
reference.
Use For
Helping to reduce exposure to certain airborne particulates such as coal, silica, iron ore, metal, wood,
biological and certain other particles, and liquid or non-oil based particles from sprays that do not also emit
oil aerosols or vapors. Use for certain metal fumes produced from welding, brazing, cutting and other
operations involving heating of metals. Follow all applicable local regulations For additional information on
3M use recommendations for this class of respirator please consult the 3M Respirator Selection Guide found
at www.3M.com/respiratorselector or call 1-800-247-3941 in U.S.A. In Canada, call 1-800 267-4414.
Do Not Use For
Do not use for gases and vapors, oil aerosols, asbestos, or sandblasting, unless nozzle and blast are physically
separated from the operator in an exhaust-ventilated enclosure; particulate concentrations that exceed either
10 times the occupational exposure limit or applicable government regulations, whichever is lower.* This
respirator does not supply oxygen.
In the U.S., do not use when OSHA substance specific standards, such as those for arsenic, cadmium, lead in
the construction industry, or 4,4’-methylene dianiline (MDA), specify other types of respiratory protection.
Use Instructions
1. Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this
respirator during all times of exposure can reduce respirator effectiveness and may result in sickness or
death.
2. Before occupational use of this respirator, a written respiratory protection program must be implemented
meeting all the local government requirements. In the United States, employers must comply with OSHA
29 CFR 1910.134 which includes medical evaluation, training, and fit testing.
3. The particles which can be dangerous to your health include those so small that you cannot see them.
4. Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress
occurs.
5. Store the respirator away from contaminated areas when not in use.

3
6. Inspect respirator before each use to ensure that it is in good operating condition. Examine all the
respirator parts for signs of damage including the two headbands, noseclip, and if applicable: nosefoam,
valve, and faceseal.
•Ensure two headbands are securely fastened to the respirator.
•For respirators with nosefoam, inspect nosefoam to ensure it is fully adhered to the respirator, not
torn, not degraded, and is centered under noseclip.
•Inspect noseclip to ensure it is fully adhered to the respirator and there are no sharp edges protruding
from the respirator.
•Inspect the respirator for holes, tears or separated seams.
•For valved respirators, ensure respirator valve diaphragm is present and functioning properly.
•For respirators with adjustable straps, ensure straps maintain tension when donned.
•For respirators with a faceseal, ensure faceseal is fully adhered to the respirator and not torn or
degraded.
The respirator should be disposed of immediately upon observation of damaged or missing parts. Filtering
facepiece respirators are to be inspected prior to each use to ensure there are no holes in the breathing zone
other than the punctures around staples and no damage has occurred. Enlarged holes resulting from ripped or
torn filter material around staple punctures are considered damage. Immediately replace respirator if
damaged. Small punctures around the staples are normal and do not interfere with the respirator’s
compliance with NIOSH approval requirements.
7. Dispose of used product in accordance with applicable regulations.
Use Limitations
1. This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.
2. Do not use when concentrations of contaminants are immediately dangerous to life or health, are
unknown or when concentrations exceed 10 times the permissible exposure limit (PEL) or according to
specific OSHA standards or applicable government regulations, whichever is lower.*
3. Do not alter, wash, abuse or misuse this respirator.
4. Do not use with beards or other facial hair or other conditions that prevent a good seal between the face
and the sealing surface of the respirator.
5. Respirators can help protect your lungs against certain airborne contaminants, however, they will not
prevent entry through other routes such as the skin, which would require additional personal protective
equipment (PPE).
6. This respirator is designed for occupational/professional use by adults who are properly trained in their
use and limitations. This respirator is not designed to be used by children.
7. Individuals with a compromised respiratory system, such as asthma or emphysema, should consult a
physician and must complete a medical evaluation prior to use.
8. When stored in accordance with temperature and humidity conditions specified below, the product may
be used until the “use by” date specified on the packaging.

4
Storage Conditions and Shelf Life
Before use, store respirators in the original packaging, away from contaminated areas, dust, sunlight, extreme
temperatures, excessive moisture and damaging chemicals. When stored in accordance with temperature
and humidity conditions specified below, the product may be used until the “use by” date specified
on packaging. Always inspect product and conduct a user seal check before use as specified in User
Instructions. If you cannot achieve a proper seal, do not enter the contaminated area. See your
supervisor.
Time Use Limitation
If respirator becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area
immediately and replace the respirator.
Fitting Instructions:
Must be followed each time respirator is worn.
Fig. 1 Fig. 2 Fig. 3a
-4oF
-20
o
C
+86oF
+30
o
C
<80%
End of Shelf Life
Use respirators before the “use by” date specified on packaging
Storage Temperature Range
-20°C (-4°F) to +30°C (+86°F).
Storage Maximum Relative Humidity
<80% RH

5
Fig. 3b Fig. 4 Fig. 5
1. Keep elastic strap flat (untwisted) and thread the top elastic strap through the top buckle. Repeat for the
bottom elastic strap. Place the bottom elastic strap around the head, just below the ears. Untwist the strap.
2. Pull the top strap over your head, resting it above the ears at the top back of your head. Untwist the strap.
3. Adjust the strap tension by pulling the straps as shown (Fig. 3a). Strap tension may be decreased without
removing respirator from the head by pushing out on the back of the buckle (Fig. 3b).
4. Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose
area to the shape of your nose by pushing inward while moving your fingertips down both sides of the
nosepiece.
!Pinching the nosepiece using one hand may result in improper fit and less effective respirator
performance. Use two hands.
5. Perform a User Seal Check prior to each wearing. To check the respirator-to-face seal, place both hands
completely over the respirator and inhale sharply. Be careful not to disturb the position of the respirator.
A negative pressure should be felt inside the respirator. If any leakage is detected, readjust the position of
the respirator according to Steps #3 and #4. If you CANNOT achieve a proper fit, DO NOT enter the
contaminated area. See your supervisor.
Removal Instructions
See Fig, 3b of Fitting Instructions and decrease strap tension as described. Cup respirator in hand to maintain
position on face and pull bottom strap over head. Still holding respirator in position, pull top strap over head
and remove respirator.
NIOSH Approved: N95
At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.

6
This respirator contains no components made from natural rubber latex.
FOR MORE INFORMATION
In United States, contact:
Website: 3M.com/PPESafety
Technical Assistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or
1-651-737-6501
3M Personal Safety Division
3M Center, Building 0235-02-W-70
St. Paul, MN 55144-1000
3M and Cool Flow Valve are trademarks of 3M
Company, used under license in Canada.
© 3M 2022 . All rights reserved.
98-0060-0145-1/3
3M
ST. PAUL, MN, USA
1-800-243-4630
THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATION:
TC-
Protection
1
Respirator Cautions and Limitations
2
8212 8214 8512 8514
84A-0454 N95 X X X X ABCJMNOP
1. PROTECTION
N95 - Particulate Filter (95% filter efficiency
level) effective against particulate aerosols
free of oil; time use restrictions may apply.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks. B-6/13/98
Other manuals for 8212
1
Table of contents
Other 3M Respiratory Product manuals
Popular Respiratory Product manuals by other brands

Cerva
Cerva OTTO SCHACHNER 243004 Instructions for use

Respirex
Respirex SIMB023 instruction manual

FLAEM NUOVA
FLAEM NUOVA Pro Line Neo Spire P0713EM Instructions for use

Phenotype
Phenotype PE-05 User instruction

Trudell Medical International
Trudell Medical International AeroChamber Plus Flow-Vu Chamber quick start guide

Spasciani
Spasciani SK 1203 manual