Aaeon AOP-8070 User manual

Operator Panel AOP-8070
AOP-8070
Marvell PXA270
520MHz Processor
Fanless Operator Panel PC
With 7” 16:9 WQVGA
TFT LCD
AOP-8070 Manual 3rd Ed.
January 2011

Operator Panel AOP-8070
i
Copyright Notice
This document is copyrighted, 2011. All rights are reserved. The
original manufacturer reserves the right to make improvements to
the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated, or
transmitted in any form or by any means without the prior written
permission of the original manufacturer. Information provided in
this manual is intended to be accurate and reliable. However, the
original manufacturer assumes no responsibility for its use, or for
any infringements upon the rights of third parties that may result
from its use.
The material in this document is for product information only and is
subject to change without notice. While reasonable efforts have
been made in the preparation of this document to assure its
accuracy, AAEON assumes no liabilities resulting from errors or
omissions in this document, or from the use of the information
contained herein.
AAEON reserves the right to make changes in the product design
without notice to its users.

Operator Panel AOP-8070
ii
Acknowledgments
All other products’ name or trademarks are properties of their
respective owners.
•Award is a trademark of Award Software International, Inc.
•RTL is a trademark of Realtek Semi-Conductor Co., Ltd.
•Microsoft Windows®is a registered trademark of Microsoft
Corp.
•IBM, PC/AT, PS/2, and VGA are trademarks of International
Business Machines Corporation.
•ESS is a trademark of ESS Technology, Inc.
•UMC is a trademark of United Microelectronics Corporation.
•SMI is a trademark of Silicon Motion, Inc.
•Creative is a trademark of Creative Technology LTD.
All other product names or trademarks are properties of their
respective owners.

Operator Panel AOP-8070
iii
Packing List
Before you begin operating your PC, please make sure that the
following materials are enclosed:
•AOP-8070 Fanless Panel PC
•Mounting bracket, screws and sponge
•CD-ROM for manual (in PDF format) and Windows CE
SDK
If any of these items should be missing or damaged, please contact
your distributor or sales representative immediately.

Operator Panel AOP-8070
iv
Safety & Warranty
1. Read these safety instructions carefully.
2. Keep this user's manual for later reference.
3. Disconnect this equipment from anyAC outlet before cleaning. Do
not use liquid or spray detergents for cleaning. Use a damp cloth.
4. For pluggable equipment, the power outlet must be installed near
the equipment and must be easily accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a firm surface during installation. Dropping
it or letting it fall could cause damage.
7. The openings on the enclosure are for air convection. Protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct before
connecting the equipment to the power outlet.
9. Position the power cord so that people cannot step on it. Do not
place anything over the power cord.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the
power source to avoid damage by transient over-voltage.
12. Never pour any liquid into an opening. This could cause fire or
electrical shock.
13. Never open the equipment. For safety reasons, only qualified
service personnel should open the equipment.
14. If any of the following situations arises, get the equipment
checked by service personnel:
a. The power cord or plug is damaged.
b. Liquid has penetrated into the equipment.
c. The equipment has been exposed to moisture.

Operator Panel AOP-8070
v
d. The equipment does not work well, or you cannot get it
to work according to the user’s manual.
e. The equipment has been dropped and damaged.
f. The equipment has obvious signs of breakage.
15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT
WHERE THE STORAGE TEMPERATURE IS BELOW -20°C
(-4°F) OR ABOVE 60°C (140°F). IT MAY DAMAGE THE
EQUIPMENT.
FCC
This device complies with Part 15 FCC Rules.
Operation is subject to the following two
conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received including
interference that may cause undesired
operation.
Caution:
There is a danger of explosion if the battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the
manufacturer’s instructions and your local government’s recycling or
disposal directives.

Operator Panel AOP-8070
vi
Below Table for China RoHS Requirements
产品中有毒有害物质或元素名称及含量
AAEON Panel PC/ Workstation
有毒有害物质或元素
部件名称 铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
印刷电路板
及其电子组件 ×○○○○○
外部信号
连接器及线材 ×○○○○○
外壳 ×○○○○○
中央处理器
与内存 ×○○○○○
硬盘 ×○○○○○
液晶模块 ×○○○○○
光驱 ×○○○○○
触控模块 ×○○○○○
电源 ×○○○○○
O:表示该有毒有害物质在该部件所有均质材料中的含量均在
SJ/T 11363-2006 标准规定的限量要求以下。
X:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出
SJ/T 11363-2006 标准规定的限量要求。
备注:
一、此产品所标示之环保使用期限,系指在一般正常使用状况下。
二、上述部件物质中央处理器、内存、硬盘、光驱、触控模块为选购品。

Operator Panel AOP-8070
vii
Contents
Chapter 1 General Information
1.1 Introduction................................................................1-2
1.2 Specification..............................................................1-3
1.3 Dimension .................................................................1-8
Chapter 2 Hardware Installation
2.1 Panelmount Installation.............................................2-2
2.2 COM Connector ........................................................2-3
2.3 DIO & RS-485 (D-sub 9 Female Connector) ............2-3
Chapter 3 Software Installation Guide
3.1 Introduction................................................................3-2
3.2 Permanent Storage...................................................3-2
3.3 Boot Up Execution File ............................................3-2
3.4 Hive Based Registry..................................................3-2
3.5 Demo Applications ....................................................3-3
3.6 SDK Installation.........................................................3-3

Operator Panel AOP-8070
Chapter 1 General Information 1- 1
General
Chapter
1
Information

Operator Panel AOP-8070
Chapter 1 General Information 1- 2
1.1 Introduction
The AOP-8070 operator panel is a Marvell Xscale processor
computer that is designed to serve as a human machine interface
(HMI). It is a PC-based system with 7” 16:9 WQVGA TFT LCD
display, onboard Ethernet controller and multi-COM port interfaces.
With a built-in CompactFlash socket, the AOP-8070 is as compact
and user friendly as a multi-function computer. In addition, its "fit
anywhere" design makes it very flexible and is able to be used in
many different kinds of installations. It can be wallmount,
panelmount or mounted on DIN Rail.
For system integrators, this simple, complete, compact and highly
integrated system let you easily build an operator panel into your
applications. Common industrial applications include factory
automation systems, precision machinery, and production process
control. It is also suitable for many non-industrial applications,
including vending machine, and car park automation. Our operator
panel is a reliable, cost-effective solution to your application's
processing requirements.

Operator Panel AOP-8070
Chapter 1 General Information 1-3
1.2 Specification
System
•CPU Marvell PXA270 520MHz
Processor
•Memory Onboard 128MB SDRAM
•LCD/CRT Controller Marvell PXA270-shared
system
•Ethernet Davicom DM9000AEP
10/100Base-TX RJ-45
connector x 1
•I/O Port 2 serial ports:
RS-232 x 1 (D-SUB 9
connector), RS-485 x 1
(D-SUB 9 female connector);
4 USB 1.1 ports; 1 digital I/O
(supports up to 6 in and 6 out)
•Storage Disk Drive Type II CompactFlash slot
•OS Support Windows CE 6.0
Mechanical
•Construction Plastic chassis (IP65 certified
front panel)
•Front Panel Color Black
•Mounting Panel Mount, VESA 75mm

Operator Panel AOP-8070
Chapter 1 General Information 1- 4
holes, DIN Rail (Optional)
•Dimension 8.9” (W) x 6.1” (H) x 1.97” (D)
(225mm x 156mm x 52mm)
•Gross Weight 1.65 lb (0.75 kg)
Environmental
•Operating Temperature 32oF~113oF (0oC~50oC)
•Storage Temperature -4oF ~140oF (-20oC ~60oC)
•Operating Humidity 10% to 90%@40oC,
non-condensing
•Vibration Random Operation 1G,
5-500Hz
•Shock 15G peak acceleration (11
msec. duration)
•EMC CE/FCC Class A
•Safety UL60950
•Power Supply DC Input 25W
Input: +10V DC~24V DC
LCD
•Display Type 7” 16:9 WQVGA
•Max. Resolution 480 x 234
•Max. Colors 262K
•Dot Size 0.204mm x 0.204mm
•Luminance 350cd/m2 (TYP.)

Operator Panel AOP-8070
Chapter 1 General Information 1-5
•Viewing Angle 120o(H) x 100o(V)
Touch screen
•Type 4-wire, analog resistive
•Light Transmission 80%
•Lifetime 1 million activations
•OS Support Windows CE. 6.0
Note: All AAEON's LCD products are manufactured with High
precision technology. However, in all LCD panels there maybe a small
number of defective pixels that do not change color. This is a normal
occurrence for all LCD displays from all manufacturers and should not
be noticeable or objectionable under normal operation. AAEON qualify
the LCD panel following industry standard: total 7 dead pixels on a
screen or if there are 3 within 1 inch square area of each other on the
display.

Operator Panel AOP-8070
Chapter 1 General Information 1- 6
IP65 Certified front
panel with
touchscreen
Ethernet port
RS-485+DIO port
RS-232 port
Dual USB ports
Power
Connector USB Client
Dual USB ports

Operator Panel AOP-8070
Chapter 1 General Information 1-7
CompactFlash
Card Slot
V
ESA 75mm
Screws

Operator Panel AOP-8070
Chapter 1 General Information 1- 8
1.3 Dimension

Operator Panel AOP-8070
Chapter 2 Quick Installation Guide 2-1
Hardware
Installation
Chapter
2

Operator Panel AOP-8070
Chapter 2 Quick Installation Guide 2 - 2
2.1 Panelmount Installation
The display panel can be mounted into the wall. You will need the
screws along with the mounting brackets, which be packed in the
accessory box. Follow the steps below:
Before you start to follow the instructions, please place the
display panel into the wall. See the following illustration on the
left.
Step 1: Place the mounting brackets and plug the screw.
Step 2: Aim the mounting set at the hole on the monitor.
Step 3: Fix the monitor with the mounting set by screwing it.
Step 4: You’ve completed the preliminary when the mounting set
is tightened. Next, repeat the steps and tighten all
mounting set around the monitor until the monitor is
firmly mounting on the wall.

Operator Panel AOP-8070
Chapter 2 Quick Installation Guide
2 - 3
2.2 COM Connector
Pin Signal Pin Signal
1 DCD1 2 RXD1
3 TXD1 4 DTR1
5 GND 6 DSR1
7 RTS1 8 CTS1
9 RI1
2.3 DIO & RS-485 (D-Sub 9 Female Connector)
Pin Signal Pin Signal
1 RS-485 Data - 2 DIO Input/Output 1
3 RS-485 Data + 4 DIO Input/Output 2
5 GND 6 DIO Input/Output 3
7 DIO Input/Output 4 8 DIO Input/Output 5
9 DIO Input/Output 6

Operator Panel AOP-8070
Chapter 3 Software Installation Guide 3-1
Software
Chapter
3
Installation
Guide
Table of contents
Other Aaeon Control Panel manuals
Popular Control Panel manuals by other brands

Garmin
Garmin G1000 NXi Cockpit reference guide

Altec Lansing
Altec Lansing 1605C SIGNAL PROCESSING manual

Servotronix
Servotronix CDHD2 manual

Gira
Gira System 3000 operating instructions

Dyer
Dyer PS-24-1-U Original instructions

Kentec Electronics
Kentec Electronics Solo 2 Lite Installation commissioning and operating manual