Aampal TMR 501 User manual

1
MULTI FUNCTION DIGITAL TIMER-TMR_501
OPERATING INSTRUCTIONS
Thank you for purchasing this
Multi-Function Digital Timer.
P l e a s e
read this manual before operating
the unit. Store this manual in a
safe, easily accessible place for
your future reference.
www.aampal.com
FUNCTIONS OF KEYS:
S.NO
SYMBOLS
NAME OF KEY
FUNCTIONS
1
MENU KEY
To Change Settings of Timer.
2
SCROLL KEY
Scroll to next Parameter Configuration.
3
DECREMENT KEY
To Decrease the Value.
4
INCREMENT KEY
To Increase the Value.
5
Enter
Reset
ENTER KEY
To Save New Parameter Values.
CAUTION:
➢To avoid electric shock, power supply of the unit should be kept off while wiring.
➢Wiring should be done strictly as per the terminal layout, given in the manual.
➢This unit is not intended for outdoor use.
➢The power connection cable must have a cross-section of at least 1mm and insula-
tion capacity of at Least 1.5kV.
➢Avoid inflow of dust and contact of conductive material with the internal circuitry
of the unit.

2
SPECIFICATIONS:
➢Display: 6-digit seven segment display0.3” height red color.
➢Supply: 230V AC, 50 Hz.
➢Count Direction: Up or Down.
➢Operating Modes: ON/OFF first One cycle, Number of cycles, Cyclic.
➢Time Ranges :1 to 99999 sec/mins/hrs.
➢Size (in mm): 96(W) X 96(H) X 110(D).
➢Reset Type: Internal or External.
➢Weight: 350 grams.
1.0. View Operation:
ON OFF HM S
To Press Menu Key
ON OFF HM S
To Press Menu Key
ON OFF HM S
To Press Menu Key
ON OFF HM S
To Press Menu Key
ON OFF H M S
.
.
.
Current Timer Value
(Default View)
Set First On time/Off Time
Set Number of Times
.
Set ON Time
.
Set OFF Time

3
To Press Menu Key
ON OFF H M S
ON OFF H M S
To Press Menu Key
ON OFF H M S
To Press Menu Key
ON OFF HM S
To Press Menu Key
ON OFF H M S
To Press Menu Key
ON OFF HM S
2.0. Edit Operation:
2.1 Unlock Editor Window:
Step 1:
Only Enter Password to
Edit Timer Settings
otherwise to not edit.
Step 2:
Using Menu key to go to
password ()Window.
Step 3:
Enter the Password (default password - 1234) to Unlock the Editor Window.
Note:
➢Menu Key use to change View (Number of Times, On Time
Format, Off Time Format, Memory Setting).
➢Scroll key use to select digits.
➢Up& down keys to increment &Decrement Blinking values.
➢Blinking Digits Only Edit.
.
Memory On/ Off
.
Auto Start
.
Password
.
Reset Type
.
Password
.
Set Direction of Timer

4
2.2 Set Number of Times ():
Step 1:
For Default Setting Timer set for Cyclic Mode (Closed Loop).
Step 2:
Using UP & DOWN Key Change Mode. (Ones,2, 3…...…).
2.3 Edit ON Time ():
Step:1
Using Menu Key to go to On Time Setting(H).
Step:2
Set ON-Time Format (Seconds, Minutes, Hours).
Step:3
Using UP & DOWN Key to increment and decrement the ON-Time values and Scroll key use to shift
next digit.
2.3 Edit Off Time ():
Step:1
Using Menu Key to go to Off Time Setting(L).
Step:2
Set OFF-Time Format (Seconds, Minutes, Hours).
Step:3
Using UP & DOWN Key to increment and decrement the OFF-Time values and Scroll key use to
shift next digit.
2.4. Edit Direction ():
Step:1
Using Menu Key to go to Direction setting ()Window.
Step:2
Using UP & DOWN Key to Set Direction of Timer (UP or Down).
2.5. Memory Setting ():
Step:1
Using Menu Key to go to Memory setting ()Window.
Step:2
Using UP & DOWN Key to Change Memory Mode (ON or OFF).
2.6. Enable Auto Start Mode ():
Step:1
Using Menu Key to go to Auto Start setting ()Window.
Step:2
Using UP & DOWN Key to Change Auto Start Mode (ON or OFF).

5
2.7. Reset Type ():
Step:1
Using Menu Key to go to Reset setting ()Window.
Step:2
Using UP & DOWN Key to Change Reset Type (Rising Edge or Falling Edge).
Step:3
If Left Ideal for 10sec Timer editor window automatically close.
TERMINAL CONNECTION:
VIEW: BACK SIDE OF MULTI FUNCTION DIGITAL TIMER
Terminal
Description
1-2-3
Neutral –Line(220v)-Line(440v)
4
Normally Open Terminal for Relay
5
Common Terminal for Relay
6
Normally Close Terminal for Relay
7
+VCC
8
NC
9
Hold / Pause
10
11
Ex-Reset
12
Note:
➢Using Menu Key to View the Timer settings one by one.
➢Without password access Not allowed to edit Timer Setting.
➢If Left Ideal for 10sec Timer editor window automatically close.

6
LOAD CONNECTIONS:
1. For Load current less than 2A: 2. For Heavy Loads Use Contactor:
➢Load Characteristics:
UP TIME DOWN TIME
Document Revision: RTC_02 Rev 1
Last update: July -2019
© 2019 Aampal–All rights reserved.
NOTE:
✓Use snubber as shown above to increase relay life.