LocalEdit Mode givesyouthe abilitytoadjust some individualkeypad functionality.
Including:12/24 hourtime,Temperature display,KPTamper,KPsoftwareversion,KPAddress,
Calibrate Temperature,BacklightBrightness,DisplayContrastandBeeperTone.
To Enter LocalEditMode,pleasepress thenthen
The displaywill thenread
To Exit LocalEditMode,please press then
OnceinLocalEditModeusetheprogrammingaddressesbelowtomake changesif required.
P=E=ToIncreasepress ToDecreasepress
P 900 E 1ON =12-hourclock, 1OFF =24-hourclock
2ON =ClockandTemperature displayedalternatively, 2OFF =ClockOnly
3ON =DisplayTemperaturewhenENTER buttonispressed, 3OFF =Featuredisabled
4ON =EnableKeypad Tamper (Notavailable onthisKeypad)
5ON =All Lightswill turnoff after90secondsofinactivity.
P 901 E Keypad Software Version, theKPcurrentsoftwareversionwill be displayed.
P 902 E Keypad Address (1-8) keypadsonthesamesystemmusteachhave adifferentaddress
P 903 E Calibrate Temperature Sensor, the currenttemperaturewill be displayed.
(Warning don’tadjustthis locationunless youhaveacalibrated temperaturesourceavailable)
P 904 E Backlight Brightness, displaywill readto adjustpress or
P 905 E LCD Contrast, displaywill readto adjustpress or
P 906 E BuzzerTone, displaywill readtoadjustpress or
P 920 E Default all KeypadLocalEditProgrammingOptionswill be returned to factorydefault.
Note,afteradjustinganyprogramming options,mustbepressedto savechanges.
*YoucannotaccessLocalEditModeif the systemisArmedorStayArmed
Page3/8
LightsOutMode: Thisgreatlittle feature isperfectif youfind thekeypadbacklightistoo bright,
wheninstalled inabedroom.Ifoption 5isturnedOnunder LocalEdit Mode address P 900E,the
backlightbehind the displayand the buttonswill turnoff,after90secondsofnozoneactivity.Ifa
zone isthentriggered thebacklightwill come backonfor90 seconds.Thebacklightwill alsocome
backonif a buttonispressed.
EasierProgramming: We’ve addedasimple stepthroughabilitytocommonlyused programming
addresses.ForexampleenrollingRadiopendants,startlikenormalinprogrammodethenP18E21E
once thefirstslot isloaded,pressingwill stepyouto thenextslot forloading andsoon.
Thisfeature worksonmostaddresses,suchasusercodes,userpermissions,phonenumbers&more