Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 2
1. Introduction
KZC-800-U/H/M KZC-900-U/H
Integrated access controllers/readers
The KZC-800-U/H/M i KZC-900-U/H access control units realize the card reading
and keypad operation functions, lock, alarm, ring bell, exit button and the mag-
netic contact switch on the door. Those units can be use as standalone controller
or standard Wiegand reader.
These models supports 13.56MHz IC Mifare cards (KZC-800-M) or 125KHz EM,
HID Prox cards (KZC-800-U/H i KZC-900-U/H ). It controls 1 door, supports up
to 2000 users in total, each user have one card and one PIN (PIN - 1234 as de-
fault, should be change for normal using).
The access control unit supports 1 master code, one manager add card, one
manager delete card, 1 anti-duress card and 1 anti-duress PIN, providing users
with easy operation and safe guarantee.
Main Features
Aluminum alloy case, waterproof, fully potted, confirms to IP65
Touch panel
Built-in 125KHz (EM, HID card) and 13.56MHz(IC, CPU card, ISO14443A)
reader ( KZC-800-M only)
Digital backlit key. The back light can be set to Normal ON, Normal OFF or
Auto.
With door bell function, build-in or external door bell optional.
Multi-function, operating as slave reader, single door, anti-pass back func-
tion, etc., suitable for various occasions.

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 3
Detail features
2 000 users with card and PIN
3 identification modes: card, PIN, card + PIN
Read both 125KHz EM & HID card
PIN length: 4-8 digits
Pulse mode, Toggle mode of lock relay
Wiegand 26-37 input & output
Can be worked as controller or reader
One relay output for door opening, inputs for door status detecting and open door by button
Card block enrollment
Manager cards for adding or deleting card user easily
Very low power consumption (35mA)
Backlight keypad
Light and sound of keypad can be set on/off
Support door bell connection
Built in light dependent resistor (LDR) for anti tamper
Built in buzzer
Red, yellow and green LED display the working status
12-24V DC
Operating Voltage 12~24V DC
User Capacity 2 000 with card and PIN (1234 - default PIN)
Keypad 12 keys, 3 x 4 digits and 2 x 6 digits (KZ-900)
Card Type EM & HID 125 KHz card, Mifare (13,56 MHz)
Card Reading Distance 3~6 cm (125 kHz), 2~5 cm (13,56 MHz),
Recommended supply power 2A (controller unit plus electric lock)
Idle Current ≤35mA
Lock Output Load Maximum 1A
Alarm Output Load Maximum 1A
Bell Output Load Maximum 1A
Operating Temperature -20~60℃
Operating Humidity 0%~95% (non condensing)
Environment Confirms to IP65
Adjustable Door Relay time 1~99 seconds, 3s - factory default
Adjustable Alarm Time 0~3 minutes, 1 min. - factory default
Wiegand Interface Wiegand 26~37 input & output
Wiring Connections Electric lock, External alarm, Door status (NC),
Exit button (NO), Bell
Dimensions:
KZC-800-U/H/M
KZC-900-U/H
125 x 83 x 22 mm (HxWxD)
159 x 43 x 22 mm (HxWxD)
Technical specifications

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 4
Unit installation
Put the paper sticker (included in box) on the wall in correct horizontal and
vertical position in the place where controller should be locate
Drill 4 holes diameter 6mm(rubber bungs)on the wall for the screws and
1 hole 30 or 22mm for the cable - as written on the sticker (figure 1)
Fix the metal product bracket firmly on the wall with 4 flat head screws
Thread the cable through the cable hole
Attach the unit to the metal bracket (figure 2)
Fix 2 pcs. safe screws at the bottom of the unit using supplied tools (fig. 3)

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 5
2. Access standalone controller mode
In this mode unit works as standalone controller. This is factory default
mode (command 7-1-1-#). It’s possible to connect additional reader for two way
control and activate anti-passback feature. To change unit for Wiegand reader
mode please use command: 7-1-0-# (this mode is describe on next pages) .
Wiring diagram
Color Function Description
Light green BELL_A Bell control output
Pink BELL_B Bell control output
Red +12V Supply power input (12~24V DC)
Black GND Supply power input (12~24V DC)
Green D0 Wiegand input
White D1 Wiegand input
Brown D_IN Door contact input
Yellow Open Request to Exit Button input
Blue NO Lock relay output
Purple COM Lock relay output
Orange NC Lock relay output
Gray ALARM Alarm output
Lock A connection - for NC type - Normally Close - locked without supply power
Lock B connection - for NO type - Normally Open - locked with supply power

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 6
Installation and Wiring Diagram
Principle of Electronic Lock
The relay will close contact to unlock the lock and will re-
lease after unlocking
COM: common, relay contact
NC: normal close, normally keep closed to COM
NO: normal open, normally keep opened to COM
Wiring of electronic lock
Connect COM and GND, connect two ends of electronic
lock with +12V and NO(or NC), complete the circuit.
Type A electronic lock: Fail Secure lock (Unlock when
power on), such as Electronic Controlling Lock, smart lock
etc.
Type B electronic lock: Fail Safe lock (Unlock when power
off), such as Electromagnetic Lock, Electronic Bolt Lock,
etc.
1N4004 Diode: prevent high voltage to two ends of the
electronic lock while the contact of relay disconnect .
Without diode, there will be high voltage pulse interfer-
ence to circuits and the life time of the relay will be
greatly reduced.
Principle of Alarm Connector
The field-effect tube will be conducted when alarm is acti-
vated; It will be not conducted when alarm is removed
Principle of Door Bell Connector
Each press of door bell button, contact of relay in
BELL_A and BELL_B will close contact for 200mS then
release.

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 7
3. Manager Card operation
3.1 Add user card(s)
Cards can be added continuously.
3.2 Delete user card(s)
Cards can be deleted continuously.
4. User Operation
4.1 To unlock the lock by one card
4.2 To unlock the lock for card and PIN users
4.3 To unlock the lock for card or PIN users
4.4 To unlock the lock for multi cards
Time interval can not exceed 5s. Precondition: Set the door entry by card only,
and set “2-10” for opening the door by multi cards.
4.5 Toggle Mode
In normal mode, every time a valid card/tag read or PIN input, the relay will op-
erate, for the pre-set relay pulse time.
In Toggle mode, every time a valid card/tag read or PIN input, the relay changes
state, which will not turn back until read card/tag or input PIN again.
Read manager add card Read User card Read manager add card
Read manager delete card Read User card Read manager delete card
Read valid card once Lock will be unlocked
Read valid card once Input 4-6 digits PIN # Lock will be unlocked
Read valid card once, or Input 4-6 digits PIN # Lock will be unlocked
Read 2-10 valid card Lock will be unlocked

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 8
* Read card Input old PIN # Input new PIN # Input new PIN #
* User ID
number
Input old PIN # Input new PIN # Input new PIN #
4.6 To change the PIN of a PIN user
Or
Remark:
For the users with card and default PIN “1234”, must read card to change the
PIN for the first time.
For users without card, must get ID number and initial new PIN from previous.
4.7 Door Bell
Press the door bell button on the access control unit, the buzzer will sound ring
back tone, at the same time, the I box's built-in door bell or the outer door bell
will ring.
5. Alarm
5.1 Anti-tamper Alarm
When the access control unit is disassembled illegally, the access control unit's
buzzer and the external alarm will operate.
5.2 Door status contact
When connect with door status contact, if the door is opened illegal, the access
control unit's buzzer and the external alarm will operate.
5.3 Anti-duress alarm
When read duress card / input 8 digits duress PIN#, the corresponding lock will
open, at the same time, the external alarm will operate, but the access control
unit's buzzer will not operate.
5.4 To remove the alarm
Read valid card or input master code can remove the alarm. If there is no opera-
tion, the alarm will remove automatically after 1 minute.
6. Keypad lockout or alarm
To prevent consecutive enter of an invalid master code, user password, or anti-
duress or invalid card, this function will be activated after 10 times consecutive
errors input. There are 3 mode available: No keypad lockout or alarm, keypad
locked for 10 minutes, alarm for 1-3 minutes.
7. To Reset to Factory Default
Power off, power on, the LED will turn in orange after 1 second, press *within
1 second (when LED is orange), release it until hearing two shot beep, then
hearing a long beep, enter normal mode - it means reset to factory default set-
ting is successfully.
Remark: Reset to factory default, the users' information is still retained.

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 9
8. Sound and light indication
9. Master setting
Enter Master Operation Mode. It will return to normal mode if there is no right
Master PIN input in 5 seconds. After input of right master PIN, it will also return
to normal mode if there is no valid operation in 30 seconds. Press “#” to confirm
the input number, return to previous menu by press “*”, the logo light will indi-
cate the operation mode.
Note that to undertake the following programming, the master user must be
logged in.

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 10
9.1 Basic Operation:
5 s
50 ms

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 11
In 10 minutes, if there's 10 times ⑨
invalid card or wrong password, the
device will lock on for 10 minutes.

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 12
Remark:
①Every time a valid card/tag read or PIN input in in Toggle mode, the relay
changes state, which will not turn back until read card/tag or input PIN again.
②The door will open only when read the valid card quantity up to the quantity
set. It is only for Card Only mode.
③The card number must be consecutive, Card quantity is between 1-2000.
④After unlocking, enter the normal working state.
⑤After closed the alarm, anti tamper, anti-duress and door magnetic alarm are
invalid.
⑥Refers to static state, normal indication according to operation.
⑦Enter the administrator password correctly, the buzzer alarm in the normal
phonation.
⑧Each key press or read card, keypad backlight will light 30 sec. delay after the
close, in close state , the first press key is just to start the keyboard light,
no any function.
⑨10 times consecutive errors including: enter an invalid master code, user
password, or anti-duress or invalid card.
10. Set Wiegand ouput format option (7-2->26 to 37 bits) concern EM (Unique)
card. HID Prox output format depends of number of bits programing on card.
10. Various Working Modes Application
The device has 3 working modes:
1. Wiegand Reader
2. Standalone for single door (Factory default setting)
3. Anti-pass back for single door
Through Wiegand data lines , can make the device and external card reader are
connected together, to realize of various functions.
Card number and PIN etc information will store in the device.
The external reader only read card or as a device for input PIN, you can connect
with a numbers of readers , but function all same.
Standalone for single door Anti-pass back for single door
Access
Host
(Outside Door)
Access
Host
(Outside Door)
External
Reader
(Inside Door)

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 13
11. Wiegand Reader Mode
In this mode unit works as reader (7-1-0-#). It can be connect to the stand-
ard controller with Wiegand port. To change unit for Access Controller mode
please use command: 7-1-1-# (this mode is describe on previous pages).
11.1 Wiegand reader mode
When LED level is low, logo light will turn into Green, after 30 seconds or LED
level rising, Logo light will back to normal.
When BZ level is low, the Buzzer will beep, after 30 seconds or BZ level rising,
the Buzzer will back to normal.
When the access controller worked as reader, both card number and keypad
transmits in Wiegand format, the output data are shown by the Low Level of
D0&D1 cable:
D0: Low level means 0, green cable
D1: Low Level means 1, white cable
The Pulse Width of Low level is 40uS, Bit period is 2mS.
The digit of Card number can be set to 26~27Bit, should be matched with the
controller. (Factory default is 26Bit) Wiegand 26 card reader, HID card can out-
put Wiegand 26~37 automatically, other cards are output Wiegand 26 compul-
sively. Wiegand 27~37 card reader, all cards are forced output Wiegand 27~37.

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 14

Integrated Access Controller – Installaon manual
All rights reserved. © AAT HOLDING S.A. 15
Keypad transmission can be set in the following 3 models:
Model 0
The Reader will transmit the PIN data in card number format when it receives
the last key (#) press after PIN code
Format: Decimal card number with 10-digit , Facility Code(1st ~ 4th digit)+ PIN
Code (5th ~ 10th digit)
(Facility code is any digits between 0~15, PIN code is 4~6 digits)
Example: Facility code:15
PIN code: 2999 -> Press 2999#, then output format will be: 0015002999
PIN code: 999999 -> Press 999999#, then output format will be: 0015999999
Model 1: 4-Bit
The output data is provided in following format after every key is pressed:
1 (0001),2 (0010),3 (0011)
4 (0100),5 (0101),6 (0110)
7 (0111),8 (1000),9 (1001)
* (1010),0 (0000),# (1011)
Model 2: 8-Bit
The output data is transmitted in following format after every key is pressed:
1 (11100001),2 (11010010),3 (11000011)
4 (10110100),5 (10100101),6 (10010110)
7 (10000111),8 (01111000),9 (01101001)
* (01011010),0 (11110000),# (01001011)
11.2 Standalone for Single door
In this mode, the access host uses can open the door by valid card or PIN, it
supports connecting external card reader for exiting door.
11.3 Anti-pass back for Single Door
In this mode, access host install outside is for entering door, external reader
inside for exiting door, they build up a single door anti-pass back system,
access host is the anti-pass back master unit.
Read valid card or input PIN on access host, door will open; read valid card
or input PIN on external reader, door will open.
When input duress PIN/Card, the door will open, at the same time, the ex-
ternal alarm operates
When input duress PIN/Card on external reader, the door will open, at the
same time, the external alarm operates.
Open type forced Card Only, the user PIN is invalid.
he users can only enter door when read valid card on access host, and exit
from the inside external reader. If without the entering record from access
host, the users can not exit from the inside reader, also the users can't en-
ter in twice without the first exit record.