Accora CV1 User manual

COVID-19 Treatment Bed
INSTRUCTION MANUAL (CV1)
Welcome
The Covid-19 treatment bed (CV1) is a nursing bed classified as a Class 1 Medical
Device in accordance with the Medical Device Regulation 2017/745.
Intended Use
The Covid-19 bed is intended for an adult population and can be used in all fixed and
temporary hospital and nursing environments.
WARNINGS
•Always keep this manual available for future reference.
•Only use compatible mattresses with this bed. Refer to specification for
dimensions.
•A patient risk assessment must be carried out before both the bed
frame and / or the side rails are used.
•Always fully decontaminate the bed in between users.
•Always lock the folding arm of the legs in place by using the locking
ring to slide over the hinge at each end of the bed.
•Care should be used when using the CPR Handle, there is a risk of
entrapment when the backrest falls to flat position.
Notice to user
If a serious incident occurs in relation to this medical device, affecting the user or the patient,
then the user or patient should report the
serious incident to the medical device manufacturer
(or distributor) and, in the European Union, the user should also report the serious incident to
the Competent Authority in the member state where they are located.
IV Pole (Option: IVP-0-CV1-000)
The IV pole should be fitted to the bed frame at the head end of the bed:
Height Extension (Option: KITHA-0-CV1-000)
Maintenance, Guarantee & Disposal
Regularly check: side supports are fitted securely; legs are locked in position. The
warranty period for the Covid-19 bed is 2 years. In the event of the disposal of the
Covid-19 bed, end-of-life parts must be disposed of in accordance with current
environmental regulations.
Specification & Decontamination
Description
Value
Bed frame fits mattress dimensions
900 x 2000 mm
Height
450 mm platform height + 150 mm mattress
Safe working load / Max. patient weight
185 kg / 150 kg
Backrest positions
Pre-set positions: 30/45/60°
Cleaning and decontamination
Use hospital-grade disinfection protocols
Symbols:
Design Policy and Copyright
® And ™ are trademarks belonging to Accora Ltd unless otherwise stated. As our policy is
one of continuous improvement, we reserve the right to modify designs without prior notice.
IFU-CV1-001EN Rev 01
Accora Limited, Barrington Road, Orwell,
Cambridge SG8 5QP, United Kingdom
Tel: 01223 206100
E-mail: info@accora.uk.com
Website: www.accora.uk.com
Place the IV pole
brackets over the
main bed
frame
Insert screws
(x2)
from
inside and
tighten
1
x2
2 bolts & wing
nuts
each end
Tighten
the
wing nuts
2
3
IV Pole (Option: IVP-0-CV1-000)
Headboard
CPR Handle
Manual Backrest
Side Rails set (3 positions):
Head End, Middle, Foot End
(Option:
SDR-0-CV1-000)
Footboard
Folding legs
(locked)
Bed frame
COVID-19 Treatment Bed (CV1)
Part No: NSB
-0-CV1-000
1
4
Refer to Instruction Manual
Physical description of Adult

Assembly
Unpack and check all components. The headboard and footboard use the same
side support component.
Put mattress platform on its side. Fold out legs and straighten supporting bar.
Move locking ring so that supporting bar is locked into position. Return bed to
normal position. Check that locking ring still locks the supporting bar from moving.
To fit the headboard and footboard, hold it so the base of the support fits over the
edge of the mattress platform. Then push down gently until the side support locks
into place.
Fit the side support in a similar manner, hold it so the base of the support fits over
the edge of the mattress platform. Then push down gently until the side support
locks into place. The 3 possible positions (A, B & C) are illustrated below:
Operation
Adjusting the backrest
Using the CPR
Accessories
Siderails (Option: SDR-0-CV1-000)
The siderails come in a set of two and use the same side support component as
the head and footboard. They may be fitted to the bed in three positions on each
side of the bed. There is a blocking bar to prevent the side support being fitted in
the wrong place and creating an entrapment hazard.
To fit a side support, hold it so the base of the support fits over the edge of the
mattress platform. Then push down gently until the side support locks into place.
1
2
Fold out legs (x2)
Slide leg lockout
ring
over hinge (x2)
3
4
Align the head/
footboard brackets
over the bed frame
and push down to
click in place
Make sure
the locking
tab is locked
under the
frame
A
B
C
Bars on frame stop side
rails being fitted in
between positions
to
avoid entrapment
hazards
WARNING
S
•
Always make
sure the locking arm is
firmly locked into its position.
•
When lowering the backrest, take
the weight of the patient and slightly
lift to reposition the locking arm.
To use the Backrest:
1. Firmly take hold of the backrest at
point (a) on either side of the bed.
2. Lift the backrest until the locking
arm locks into the desired position.
1= 30°, 2= 45°, 3= 60°
1
2
3
(a)
Locking arm
CPR Handle
To Activate:
WARNING
- Make sure all limbs are
clear of the backrest.
Push the CPR handle down. This will
disengage the backrest locking arm
and allow the backrest to drop to flat.
1
2
3
NOTE:
Positions A, B & C
apply to both sides of the
bed. Shown
on either side
here for clarity.
3
2

Assembly
Unpack and check all components. The headboard and footboard use the same
side support component.
Put mattress platform on its side. Fold out legs and straighten supporting bar.
Move locking ring so that supporting bar is locked into position. Return bed to
normal position. Check that locking ring still locks the supporting bar from moving.
To fit the headboard and footboard, hold it so the base of the support fits over the
edge of the mattress platform. Then push down gently until the side support locks
into place.
Fit the side support in a similar manner, hold it so the base of the support fits over
the edge of the mattress platform. Then push down gently until the side support
locks into place. The 3 possible positions (A, B & C) are illustrated below:
Operation
Adjusting the backrest
Using the CPR
Accessories
Siderails (Option: SDR-0-CV1-000)
The siderails come in a set of two and use the same side support component as
the head and footboard. They may be fitted to the bed in three positions on each
side of the bed. There is a blocking bar to prevent the side support being fitted in
the wrong place and creating an entrapment hazard.
To fit a side support, hold it so the base of the support fits over the edge of the
mattress platform. Then push down gently until the side support locks into place.
1
2
Fold out legs (x2)
Slide leg lockout
ring
over hinge (x2)
3
4
Align the head/
footboard brackets
over the bed frame
and push down to
click in place
Make sure
the locking
tab is locked
under the
frame
A
B
C
Bars on frame stop side
rails being fitted in
between positions
to
avoid entrapment
hazards
WARNING
S
•
Always make
sure the locking arm is
firmly locked into its position.
•
When lowering the backrest, take
the weight of the patient and slightly
lift to reposition the locking arm.
To use the Backrest:
1. Firmly take hold of the backrest at
point (a) on either side of the bed.
2. Lift the backrest until the locking
arm locks into the desired position.
1= 30°, 2= 45°, 3= 60°
1
2
3
(a)
Locking arm
CPR Handle
To Activate:
WARNING
- Make sure all limbs are
clear of the backrest.
Push the CPR handle down. This will
disengage the backrest locking arm
and allow the backrest to drop to flat.
1
2
3
NOTE:
Positions A, B & C
apply to both sides of the
bed. Shown
on either side
here for clarity.
3
2

COVID-19 Treatment Bed
INSTRUCTION MANUAL (CV1)
Welcome
The Covid-19 treatment bed (CV1) is a nursing bed classified as a Class 1 Medical
Device in accordance with the Medical Device Regulation 2017/745.
Intended Use
The Covid-19 bed is intended for an adult population and can be used in all fixed and
temporary hospital and nursing environments.
WARNINGS
•Always keep this manual available for future reference.
•Only use compatible mattresses with this bed. Refer to specification for
dimensions.
•A patient risk assessment must be carried out before both the bed
frame and / or the side rails are used.
•Always fully decontaminate the bed in between users.
•Always lock the folding arm of the legs in place by using the locking
ring to slide over the hinge at each end of the bed.
•Care should be used when using the CPR Handle, there is a risk of
entrapment when the backrest falls to flat position.
Notice to user
If a serious incident occurs in relation to this medical device, affecting the user or the patient,
then the user or patient should report the
serious incident to the medical device manufacturer
(or distributor) and, in the European Union, the user should also report the serious incident to
the Competent Authority in the member state where they are located.
IV Pole (Option: IVP-0-CV1-000)
The IV pole should be fitted to the bed frame at the head end of the bed:
Height Extension (Option: KITHA-0-CV1-000)
Maintenance, Guarantee & Disposal
Regularly check: side supports are fitted securely; legs are locked in position. The
warranty period for the Covid-19 bed is 2 years. In the event of the disposal of the
Covid-19 bed, end-of-life parts must be disposed of in accordance with current
environmental regulations.
Specification & Decontamination
Description
Value
Bed frame fits mattress dimensions
900 x 2000 mm
Height
450 mm platform height + 150 mm mattress
Safe working load / Max. patient weight
185 kg / 150 kg
Backrest positions
Pre-set positions: 30/45/60°
Cleaning and decontamination
Use hospital-grade disinfection protocols
Symbols:
Design Policy and Copyright
® And ™ are trademarks belonging to Accora Ltd unless otherwise stated. As our policy is
one of continuous improvement, we reserve the right to modify designs without prior notice.
IFU-CV1-001EN Rev 01
Accora Limited, Barrington Road, Orwell,
Cambridge SG8 5QP, United Kingdom
Tel: 01223 206100
E-mail: info@accora.uk.com
Website: www.accora.uk.com
Place the IV pole
brackets over the
main bed
frame
Insert screws
(x2)
from
inside and
tighten
1
x2
2 bolts & wing
nuts
each end
Tighten
the
wing nuts
2
3
IV Pole (Option: IVP-0-CV1-000)
Headboard
CPR Handle
Manual Backrest
Side Rails set (3 positions):
Head End, Middle, Foot End
(Option:
SDR-0-CV1-000)
Footboard
Folding legs
(locked)
Bed frame
COVID-19 Treatment Bed (CV1)
Part No: NSB
-0-CV1-000
1
4
Refer to Instruction Manual
Physical description of Adult
This manual suits for next models
1
Other Accora Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual