LOOPBACK TESTING
Initiate loopback testing from the maintenance menus or use the MODE and SEL
pushbuttons. The in-band codes shown below can be sent by a test set.
Copies of this publication or the technical practice (LTPH-TP-1115-xx) can be downloaded
from the ADC website at www.adc.com. To order a hard copy, please contact your sales
representative.
HDSL2
STATUS
H
2
T
U
•
C
3
8
8
L
R
S
2
3
2
DCE
M
O
D
E
S
E
L
HiGain
HDSL2
2
SETUP
106
105
104
103
102
101
100
DSX-1OUT
DSX-1IN
205
204
203
202
201
200
119
118
117
116
115
114
113
112
111
110
Ground Ground
Frameground
Fusealarm*
Ring1
Tip1
Management bus
Ring
Tip
Factory use only
-48Vdc
219
218
217
216
215
214
213
212
211
210
209
208
207
206
109
108
107
* Fuse alarm is normally floating
and at -48 Vdc when activated.
RS-232 Craft port
The Bantam 210 jack provides bidirectional communication
between the H2TU-C and a maintenance terminal
for access to maintenance, provisioning, and
performance screens. Use jack adapter 120-1035-01
to connect a standard 9-pin terminal cable between the
serial port on a PC and the H2TU-C craft port.
CLEI code label
Four-character display
Displays status, provisioning, and
alarm messages. See tables below
for a list of message descriptions.
Status LED
System option buttons (for manual setting of
system parameters)
Use MODE and SEL to manually modify user options,
initiate loopbacks, and display DSX-1 line parameters.
1
2
3
4
Press the MODE button for 1 second and release.
The front panel alternately displays the first
system parameter and its current setting.
Press SEL to step through all possible
settings for the displayed parameter.
Press MODE to update the parameter and advance
to the next parameter.
After scrolling through all the parameters, press SEL
to confirm changes when prompted with a CONF NO
message, or press MODE to cancel all changes.
9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control: OFF
Terminal emulation software: VT100
Maintenance Terminal Modem Settings Card-edge Connector
A Customer Remote (CREM) loopback
or a Network Local (NLOC) loopback
is in effect.
Green LED Normal operation.
Red LED Fuse alarm.
Flashing Red LED HDSL2 acquisition or system alarm.
Yellow LED
Flashing Yellow LED System is in Armed (ARM) mode.
Off Line power is off. HDSL2span
Ring
Tip
List number
GNLB Loopback Commands
Loopback In-Band Code Description
NLOC 1111000 DSX-1 signal is looped back to the network at the H2TU-C.
NREM 1110000 DSX-1 signal is looped back to the network at the H2TU-R.
SMJK 11000 DSX-1 signal is looped back to the network at the H2TU-R SmartJack
module.
CREM 1111110 DS1 signal from customer is looped back to the customer at the H2TU-C.
CLOC 1111100 DS1 signal from customer is looped back to the customer at the H2TU-R.
Loopdown 11100 Deactivates any of the above loopbacks.
Front-Panel Alarm Messages (a)
(a) Front-panel alarm messages are listed in order of priority. ALRM displays prior to any alarm message.
Pressing the SEL pushbutton initiates an Alarm Cutoff (ACO) message.
Message Description (listed in priority order)
PWR FEED SHRT(b)
(b) Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.
A short between the Tip and Ring of the HDSL2 pair.
PWR FEED GND (b) The HDSL2 loop is grounded.
PWR FEED OPEN(b) A line-power open condition.
LOSW The HDSL2 loop has lost synchronization.
LLOS No signal is detected at the DSX-1 input to the H2TU-C.
RLOS No signal is detected at the DS1 input to the H2TU-R.
LAIS Line Alarm Indication Signal.
RAIS Remote Alarm Indication Signal.
LRAI An RAI condition is detected at the remote and the signal from the line unit is
error-free.
RRAI An RAI alarm (yellow) from the Customer Premises Equipment (CPE) with errors from
the line unit or network.
xxx-LOF DS1 input does not contain ESF or SF frame pattern setting of the FRMG option. (xxx
denotes either TUC or TUR.)
xxx-DBER A system DS1 Bit Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
PRMF H2TU-R Performance Report Messaging BER threshold exceeded at far end.
PRMN H2TU-R Performance Report Messaging BER threshold exceeded at near end.
xxx-HBER A system HDSL2 Block Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
xxx-MAL The margin on the HDSL2 loop has dropped below the threshold setting. (xxx denotes
either TUC or TUR.)
xxx-LA The attenuation on the HDSL2 loop has exceeded the maximum threshold value. (xxx
denotes either TUC or TUR.)
To comply with the intrabuilding wiring requirements of GR-1089
CORE, Section 4.5.9, the shields of the ABAM-type cables that
connect the H2TU-C-388 List 2 DSX-1 output ports to the
cross-connect panel must be grounded at both ends.
Network
Customer
Premises
H2TU-C H2TU-R
TLOS*
NLOC CREM CLOC
1111000
NREM
1110000 1111100
1111110
11000
SMJK
When enabled, TLOS is an automatic loopback
that occurs with an LOS at the remote DS1 input.
*
DS1DSX-1
Front Panel Diagnostic Messages (normal operating messages in bold)
Display Code Description (normal operating messages in bold)
A=xx(a)
(a) Normal operating range.
The loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ The multiplexers of the H2TU-C and H2TU-R are trying to establish synchronization.
ARM Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT? The H2TU-C is not receiving a response from the H2TU-R.
FERR A framing bit error occurred at H2TU-C DSX-1 input.
FLDL Flash download of firmware updates. (Contact Customer Service for update procedures.)
HES H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.
LBPV A local bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx(a) Indicates the power of the received HDSL2 signal relative to noise (S/N with respect to
21.5 dB). Any value of 6 dB or greater is adequate for reliable system operation.
MNGD The H2TU-C is under control of the HMU-319 network management unit.
PWR FEED OFF HDSL2 span power is turned off.
PWR FEED ON Indicates that the HDSL2 loop is not grounded or shorted.
SIG The transceivers of the H2TU-C and H2TU-R are trying to establish contact with each
other on the HDSL2 loop.
Front-Panel Configuration Options Using MODE and SEL (a)
(a) Front panel configuration options display in the order listed.
Display Code Description (default values in bold)
EQL Sets the DSX-1 Equalizer to: 0 (0 to 133 ft.), 133 (133 to 266 ft.), 266 (266 to 399 ft.),
399 (399 to 533 ft.), 533 (533 to 655 ft.).
RLBO Sets the H2TU-R line buildout to 0 dB, -7.5 dB, or -15 dB.
LPBK Enables (ENA) or disables (DIS) SmartJack loopback commands.
SPLB xxxx Configures the system for generic (GNLB) or special inband loopback commands (A1LB,
A2LB, A3LB, A4LB, A5LB).
PWRF OFF = disables HDSL2 powering. ON = HDSL2 line voltage is -185 Vdc maximum.
HBER 1E-6 or 1E-7 = alarm activates when the HDSL2 BER alarm threshold exceeds 10-6 or 10-7.
NONE = prevents generation of a system alarm due to BER.
DBER Enables (ENA) or disables (DIS) fixed 24-hour DSX-1 BER alarm threshold.
LBTO Loopback timeout = NONE, 20, 60, 120 minutes; 8 hours, 24 hours.
DS1 DSX-1 line code = AUTO, B8ZS, AMI.
FRMG DS1 frame formatting = AUTO (auto framing mode), UNFR (unframed mode), SF
(SuperFrame) and ESF (Extended SuperFrame).
RDA Enables (ENA) or disables (DIS) alarm indications due to remote DS1 LOS at the H2TU-R
input.
ALMP Enables system to output an alarm pattern: AIS or LOS.
BPVT Enables (ENA) or disables (DIS) Bipolar Violation Transparency.
NLBP Enables the H2TU-R to transmit either AIS or LOS towards the CI for any network loopback.
TLOS Enables (ENA) or disables (DIS) a logic loopback at the H2TU-R when an LOS occurs at its
DS1 input.
RTPV Enables (ENA) or disables (DIS) remote provisioning.
PBON Configures the power output levels of the H2TU-C network unit toward the customer to
comply with Default (DEF) or Enhanced (ENH) templates.
PBOC Configures the power output levels of the H2TU-C customer unit toward the network to
comply with Default (DEF) or Enhanced (ENH) templates.
Front-Panel System Information Messages (Scroll Mode) (a)
(a) To scroll through system information messages, press the MODE button for 3 or more seconds.
Code Description Code Description
CODE xxxx Line code setting (AMI, B8ZS). LIST xx Product list number.
FRM xxxx Frame pattern received from the
DSX-1 (SF, ESF, UNFR). MARG xx Margin threshold (0 to 15 dB).
Default is 4.
LATT xx Loop attenuation threshold
(0 to 40 dB). Default is 35. VER x.xx Firmware version.