Additel 260Ex User manual

1
260Ex
Handheld Multichannel Reference Recorder

ADT260Ex Handheld Multichannel Reference Recorder
-------User Manual
[Version:2211V01]
Additel Corporation

STATEMENT
This user manual provides operating and safety instructions for the ADT260Ex Handheld
Multichannel Reference Recorder. To ensure correct operation and safety, please follow the
instructions in this manual. Additel Corporation reserves the right to change the contents and other
information contained in this manual without notice.

I
Content
Safety instructions............................................................................................................................................................ 1
Special safety requirements............................................................................................................................................. 2
Intended use ...................................................................................................................................................................... 6
1. Introduction ................................................................................................................................................................... 7
1.1 Product Overview................................................................................................................................................... 7
1.2 Technical specification ........................................................................................................................................... 8
1.2.1 General specification........................................................................................................................................... 8
1.2.2 Signal measure specification (environmental temp.: 20±10℃, 1 year accuracy)....................................... 10
1.2.3 Simulate RTD measure accuracy (environmental temp.: 20±10℃) ........................................................... 11
1.3 Basic Structure..................................................................................................................................................... 14
1.4 Standard package include.................................................................................................................................... 16
1.5 Power supply description ..................................................................................................................................... 17
2.1 Main interface....................................................................................................................................................... 19
2.1.1 Status bar................................................................................................................................................... 19
2.1.2 APPs list..................................................................................................................................................... 19
2.1.3 Main function guide.................................................................................................................................... 20
2.2 Control center....................................................................................................................................................... 21
2.2.1 Date and battery ........................................................................................................................................ 21
2.2.2 Diagnostic center and screenshot.............................................................................................................. 21
2.2.3 Shortcut settings ........................................................................................................................................ 21

II
3. Data logger .................................................................................................................................................................. 22
3.1 Pressure Measurement........................................................................................................................................ 23
3.2 RTD measurement............................................................................................................................................... 25
3.3 Electrical signal measurement ............................................................................................................................. 26
3.3.1 DC Voltage measurement.......................................................................................................................... 26
3.3.2 Current measurement ................................................................................................................................ 26
3.3.3 Switch measurement ................................................................................................................................. 27
3.3.4 Pulse measurement................................................................................................................................... 27
3.3.5 Frequency measurement ........................................................................................................................... 27
3.4 Filtering ................................................................................................................................................................ 28
3.5 Scaling ................................................................................................................................................................. 29
4. System settings........................................................................................................................................................... 31
4.1 Bluetooth communication..................................................................................................................................... 31
4.2 Power management............................................................................................................................................. 31
4.3 System calibration................................................................................................................................................ 31
4.4 Services ............................................................................................................................................................... 32
4.4.1 Maintenance .............................................................................................................................................. 32
4.4.2 Restore to factory....................................................................................................................................... 32
4.4.3 Running information................................................................................................................................... 32
4.4.4 System upgrade......................................................................................................................................... 32
4.5 Personalization..................................................................................................................................................... 33
4.5.1 Sound ........................................................................................................................................................ 33

III
4.5.2 Language................................................................................................................................................... 33
4.5.3 Date & Time ............................................................................................................................................... 33
4.6 Product information.............................................................................................................................................. 34
5. Data management ....................................................................................................................................................... 35
6. Data logger .................................................................................................................................................................. 36
6.1 Display mode ....................................................................................................................................................... 36
6.1.1 Single-channel mode ................................................................................................................................. 36
6.1.2 Multi-channel list mode .............................................................................................................................. 38
6.2 Channel data........................................................................................................................................................ 39
6.3 Channel curve...................................................................................................................................................... 39
6.3.1 Following Mode.......................................................................................................................................... 39
6.3.2 Eye pattern mode....................................................................................................................................... 39
6.4 Save the data....................................................................................................................................................... 39
7. Applications................................................................................................................................................................. 40
7.1 Differential pressure module ................................................................................................................................ 40
7.2 Units converter..................................................................................................................................................... 41
7.3 Wiring help ........................................................................................................................................................... 41
7.4 Leak test .............................................................................................................................................................. 41
7.4.1 Leak Test Performing ................................................................................................................................. 42
7.5 PSV test ............................................................................................................................................................... 43
7.5.1 PSV test performing................................................................................................................................... 43
7.6 Sensor library....................................................................................................................................................... 44

IV
Figure Content
Figure 1 Basic Structure.................................................................................................................................................... 14
Figure 2 Adaptor and the power plug ................................................................................................................................ 17
Figure 3 Main interface...................................................................................................................................................... 18
Figure 4 Control center...................................................................................................................................................... 20
Figure 5 Calibrator main screen........................................................................................................................................ 23
Figure 6 RTD measurement.............................................................................................................................................. 25
Figure 7 Voltage/ frequency/ pulse/ switch wiring.............................................................................................................. 26
Figure 8 Current measurement ......................................................................................................................................... 27
Figure 9 Filter settings....................................................................................................................................................... 28
Figure 10 Scaling configurations....................................................................................................................................... 30
Figure 11 Single-channel mode......................................................................................................................................... 37
Figure 12 Multi-channel list mode ..................................................................................................................................... 38

1
Safety instructions
Warning:
To prevent the user from injury, please follow this user manual for use.
To prevent fire, electric shock, or personal injury, please do as follows:
Normal:
Please read the user manual before using the product, especially the Safety Instructions;
Please charge the battery when a low battery level is displayed in case of the measurement abnormal;
Do not expose the battery to fire or short circuit the battery;
Before using the product, please check the appearance of the product for any damage;
If the product is damaged or malfunctions, do not use it, and contact Additel;
Do not touch the metal part of the probes or test cables during use;
Please remove unnecessary probe, cable, or other accessories before using the product;
Do not use damaged or worn cable.
Attention:
To prevent damage this product or the device under tested, please obey the instruction manual for use
Do not use the instrument in a high vibration environment;
Use only the Additel power adaptor and designated battery models;
In case of working with external pressure module, refer to the Safety instructions of its manual.

2
Special safety requirements
1. WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
2. WARNING – DO NOT CHARGE THE BATTERY IN HAZARDOUS LOCATION
3. WARNING – USE ONLY the approved batteries, see Ex instruction
4. The equipment should be protected from high energy impacts
5. Do not touch the non-metallic enclosure or touch with the insulating materials only
6. The batteries used in the equipment should be the same manufacturer, model and electrochemical system
7. The conformal coating applied to PCB boards was declared meet the requirements of IEC 60664-1 and IEC 60664-
3 by manufacturer
8.Tamb:-20℃to +50℃
9. USB port should only be used in Non-hazardous areas.
10.PX connections to be made with pressure measuring module CDPX-Ex only, the connected cables and flexible
hose used for the external pressure modules are made of insulation materials, so end user should consider the risk of
electrostatic discharge during material selection and installation process
11. Metallic parts (only fasteners) presented a maximum capacitance of total 110pF, end user should consider this risk
for suitable applications
12. No additional input energy limitation are required for Type-C USB port and DC charging port when Um does not
exceed 250V (internal OVP/OCP are designed in line with IEC 60079-11)

3
13. Do not remove the silicone rubber protective sleeve from the enclosure of equipment in Hazardous area
14. IS parameters must be observed for different external measuring ports on the different models in accordance with
Ex instruction strictly and completely
15. Intrinsically safe electrical system between IS apparatus and Associated apparatus or other IS apparatus:
Item I.S Interface External Measuring Instrument System
Equipment group IIC IIC IIC
Level of protection ia ia ia
Temperature class T4 T4 T4
Ambient temperature -20°C~+50°C -20°C~+50°C
Voltage Uo Ui(30V)
Current Io Ii(100mA)
Power Po Pi(0.75W)
Cable parameters
Capacitance Co Ci Cc
Inductance Lo Li Lc
L/R ratio / / /
Grounding Isolated Isolated Isolated
Uo ≤Ui
Io ≤Ii

4
Po ≤Pi
Co ≥Ci+Cc
Lo ≥Li+Lc
Standard Compliance
EN IEC 60079-0:2018
EN 60079-11:2012
IEC 60079-0:2017 Edition 7.0
IEC 60079-11:2011 Edition 6.0
Ex information for equipment name
National regulations: ATEX directive 2014/34/EU and IECEx scheme 02
Certificate No.:TÜV 20 ATEX 8509 X and IECEx TUR 20.0009X
Ex Marking for EU-Type Examination: II 1 G Ex ia IIC T4 Ga
Ex Marking for IECEx CoC: Ex ia IIC T4 Ga
Ex Marking for UKCA certificate: CSAE 22UKEX1201
Tamb: -20℃~+50℃
IP Rating:IP20
I.S Parameters:

5
Additel 260Ex
Handheld Multichannel Reference Recorder
Input parameters, simple connection
Connection Function Ui/V Ii/mA Pi/mW Ci/nF Li/mH
J1, J3 HART (external power and external resistance) 30 100 750 10 0
J2, J3 Current measurement 30 100 750 1 0
J4, J3 Voltage, frequency, and switch measurement 30 100 750 1 0
J1, J2 Loop Circuit Transmitter Current Measuring /
HART(Internal Power and Resistance) 30 100 750 10 0
J5-J8 J9-J12 Resistance measuring 30 100 750 20 0

6
Output parameters, simple connection
Connection Function Uo/V Io/mA Po/mW Co/µF Lo/mH
J1, J3 HART (external power and external
resistance) 25.2 79.16 499 0.107 9
J2, J3 Current measurement 5 0.85 1.1 87 100
J4, J3 Voltage, frequency, and switch
measurement 5 0.85 1.1 87 100
J1, J2
Loop Circuit Transmitter Current
Measuring / HART(Internal Power and
Resistance)
25.2 79.16 499 0.107 9
J5-J8 J9-J12 Resistance measuring 5 21 26.3 85 30
Intended use
●The equipment to be used in Zone 0 hazardous area with gas group IIC.
●The equipment is used in oil and gas platforms, oil refineries, chemical and petrochemical plants, pharmaceutical
industry, energy and gas processing industries.

7
1. Introduction
1.1 Product Overview
ADT260EX is an intrinsically safe pressure and temperature logger provided by Additel. It can be used in zone 0
environment and has an 8-channel combination capability, supports measurement and logging of pressure, temperature,
barometric pressure and electrical signals. It can keep 10 million records, display the trend curve, and support Bluetooth
communication. Powerful logging capability and high-level intrinsically safe make it widely used in ex-proof pipeline field
/container pressure test, air leak test, inlet and outlet pressure test of pump station, safety valve and ex-proof membrane
test, wellhead pressure test, pipeline filter test, differential pressure transmitter/flow computing test, as well as used in the
routine calibration of pressure devices.
How to contact us
TEL:1-714-998-6899
Or visit Additel website:www.additel.com

8
1.2 Technical specification
1.2.1 General specification
Table 1 General specification
General Specification
Input Channel
Top: 2 channels RTD measurement, 1 channel electric signal measurement, φ4mm banana jacks
Right side: 2 channels for external digital pressure module, Lemo style connection
Bottom: embedded digital pressure module (model ADT158Ex) field switchable.
Internal: 1 embedded atmospheric pressure sensor
Barometric Accuracy ±55Pa
Measurement Rate
mV, V, mA & frequency and RTD: 3 times/ sec
Pressure module: 1~10 times/sec selectable (3 as default)
Barometric: 1 times/ sec
Data Storage Logging interval: from 0.1~9999 seconds, log up to 10 million readings (single channel)
Power
4000mAh, 14.4Wh explosion-proof intelligent lithium battery, charging time is 6~8 hours, the battery can be
charged independently
Typical working time 100 hours (measurement mode)
Environmental Guaranteed temperature range of technical specifications: (-10 ~ 50)°C
*Temperature coefficient: ±5 ppm FS/°C (-20 to -10)°C

9
Operating temperature: (-20 ~ 50)°C
Storage temperature range: (-30 ~ 70)°C
Humidity: 0% to 95% RH, non-condensing
Altitude: 3000 meters
Warm Up Time 10 minutes to fully meet technical specifications
Port Protection Voltage 30V max
Explosion-proof Grade
ATEX & IECEX: Ex ia IIC T4 Ga (Ta = -20°C to +50°C)
CSA: Class I, Division 1, Group A,B,C and D, T4 Class I, Zone 0, AEx ia IIC T4 Ga
Ta = -20°Cto + 50°C Ex ia IIC T4 Ga
UKCA-EX
CE Certification TUV IEC61326, IEC61010
Rohs Compliance Rohs II Directive 2011/65/EU,EN50581:2012
Protection Level IP67, 1 meter drop test
Communication Isolate USB-TYPEC (slave), Bluetooth
Display 4.4-inch color display capacitive screen, transflective, with LED backlight
Size 6.97" x 4.13" x 2.04" (177 mm x 105 mm x 52 mm) which does not include the bottom mount ADT158Ex if
installed.
Weight 1.65 lb. (0.75 kg)
Warranty Time 1 year

10
1.2.2 Signal measure specification (environmental temp.: 20±10℃, 1 year accuracy)
Table 2 Signal measure specification
Specification Range Accuracy Resolution Note
RTD Measurement
Accuracy 0~400Ω 0.01%RDG+0.005%FS[1] 1mΩ Excitation current: 1 mA
Voltage Measurement ±300mV 0.015%RDG + 0.005%FS 1uV Impedance: >100MΩ
±30V
0.015%RDG + 0.005%FS
0.1mV
Impedance: >1MΩ
Current Measurement
±30mA
0.015%RDG + 0.005%FS
0.1uA
Impedance: < 40Ω
Frequency Measurement 0.01~50000Hz (auto range) 0.005% RDG + 2 last digit 6-digit auto-
resolution Min threshold voltage: 2.5V
Units: Hz, kHz, MHz, CPM, CPH, s, ms, us
Switch On-Off
Measurement
Inspection voltage: (3 ~ 30)V
Response speed: < 10ms, supports wet and dry switch
Pulse Count
0 ~ 9999999, optional rising edge and falling edge Min threshold voltage: 2.5V
Loop Power
20V ± 10%, max output impedance: 320Ω, max load current: 25mA
Note 1:When the environmental temperature is (-20~-10) ℃, the temperature coefficient is:
(1)Measure of voltage, current and RTD:±5ppmFS/℃.
Note 2:Input characteristics:
(1) Voltage range:-300~300mV input impedance >100 MΩ;

11
(2) Voltage range:-30~30V input impedance >1MΩ;
(3) Current measure:input impedance<40Ω;
Note 3: The excitation power supply for RTD measure is 0.2mA, and each position has 4-wire, 3-wire, and 2-wire
methods. The accuracy is as follows: (given accuracy data in the table in based on 4-wire)
(1) The accuracy of the 3-wire method is 10mΩ more than the accuracy of the 4-wire method;
(2) The accuracy of the 2-wire method is 50mΩ more than the accuracy of the 4-wire method.
Note 4:Minimum threshold voltage for frequency and pulse measure:2.5V;
Note 5:The frequency measure supports following units: Hz, kHz, MHz, CPM, CPH, s, ms, μs
Note 6:There are rising edge and falling edge trigger mode available for pulse measure.
1.2.3 Simulate RTD measure accuracy (environmental temp.: 20±10℃)
Table 3 Simulate RTD measure accuracy
Sensor type Temperature(℃) Annual accuracy(℃)
PT10(385) -200~850
-200~200 0.59
200~600 0.72
600~850 0.82
PT25(385) -200~850 -200~200 0.27
200~600 0.35

12
600~850 0.41
PT50(385) -200~850
-200~200 0.16
200~600 0.22
600~850 0.27
PT100(385)
PT100(391)
PT100(3916)
PT100(3926)
-200~850
-200~200 0.10
200~600 0.16
600~850 0.20
PT200(385) -200~850
-200~200 0.32
200~300 0.34
300~600 0.41
600~850 0.48
PT400(385) -200~850
-200~0 0.15
0~200 0.18
200~600 0.25
600~850 0.30
PT500(385) -200~850
-200~200 0.16
200~600 0.22
600~850 0.27
PT1000(385) -200~850 -200~200 0.10

13
200~600 0.16
600~850 0.20
Cu10(427) -200~260 -200~260 0.56
Cu50(428) -50~150 -50~150 0.13
Cu100(428) -50~150 -50~150 0.08
Ni100(617)
Ni100(618) -60~180 -60~0 0.06
0~180 0.05
Ni120 (672) -80~260 -80~260 0.05
Ni1000 -50~150 -50~150 0.07
Note: It complies with the international temperature scale ITS90, depends on the maximum tolerance of the RTD
measurement and simulate signal output.
Table of contents
Other Additel Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

PIETRO FIORENTINI
PIETRO FIORENTINI RSE 1,2 LA N1 Use and maintenance manual

Fine Offset Electronics
Fine Offset Electronics WH5360B manual

VOLTCRAFT
VOLTCRAFT ENERGY LOGGER 3500 operating instructions

IFM
IFM SD26 Series operating instructions

Ballantine
Ballantine 340 instruction manual

IMS
IMS 8072A instruction manual