– 3 –
*36 ENTRY DELAY 2 (zone type 02) | | [60] [60]
Part. 1 †Part. 2 †00-99 = entry delay 2 time for each
partition; 50 seconds max. for UL installations
*37 AUDIBLE EXIT WARNING [1] [1]
Part. 1 †Part. 2 † 0 = no; 1 = yes
*38 CONFIRMATION OF ARMING DING [0] [0]
Part. 1 †Part. 2 †
0 = no; 1 = yes (wired keypads and RF); 2 = yes, RF only
*39 POWER UP IN PREVIOUS STATE † [1]
0 = no; 1 = yes; “1” for UL installations
DIALER PROGRAMMING (*40–*53)
In fields *40, *41, *42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '*';
#+12 for '#'; #+13 for a pause.
*40 PABX ACCESS CODE | | | | |
Enter 6 digits. If fewer than 6 digits are entered, exit by
pressing * (and press 41, if entering next field). To clear entries
from field, press *40* .
*41 PRIMARY PHONE No. | | | | | | | | | | | | | | |
Enter up to 16 digits; Do not fill unused spaces. If fewer than 16
digits entered, exit by pressing * (and press 42, if entering next
field). To clear entries from field, press * 41* .
*42 SECONDARY PHONE No. | | | | | | | | | | | | | | |
Enter up to 16 digits; Do not fill unused spaces. If fewer than 16
digits entered, exit by pressing * (and press 43, if entering next
field). To clear entries from field, press *42* .
*43 PRIMARY SUBS ACCT # (Part. 1) | | |
*44 SECONDARY SUBS ACCT # (Part. 1) | | |
*45 PRIMARY SUBS ACCT # (Part. 2) | | |
*46 SECONDARY SUBS ACCT # (Part. 2) | | |
NOTE: If using the paging feature, do not enter a
leading 0 in the subscriber account number, and do
not use digits A-F anywhere in the number. Some
paging systems provide voice mail capability, which
is activated by a leading 0 in the message.
For fields *43 - *46:
Enter 0–9; #+11 for B; #+12 for C; #+13
for D; #+14 for E; [#+15 for F]. Enter * as
4th digit, if 3+1 dialer reporting is to be
used. If only 3 digits used, exit by pressing
* (and press next field).
To clear entries from field, press *43*
,*44*, *45*, or *46* .Examples:
For Acct. 1234, enter: 1 | 2 | 3 | 4
For Acct. B234 , enter: #+11| 2 | 3 | 4
For Acct. 123, enter: 1 | 2 | 3 | *
*47 PHONE SYSTEM SELECT †[1]
If Cent. Sta.
IS NOT
on a WATS line: 0 = Pulse Dial; 1 = Tone
Dial; if Cent. Sta.
IS
on
a WATS line: 2 = Pulse Dial ; 3 = Tone
Dial.
*48 REPORT FORMAT [7] [0]
Primary Secondary
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1= 3+1, 4+1 RADIONICS STANDARD
2= 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6or undefined = 4+2 ADEMCO EXPRESS
7= ADEMCO CONTACT ID REPORTING
8= 3+1, 4+1 ADEMCO L/S EXPANDED
9= 3+1, 4+1 RADIONICS EXPANDED
† Entry of a number other than one specified will give unpredictable results.