1*17 LOBBY PARTITION [0]
Enter the "common lobby" partition (1-8)
1*18 AFFECTS LOBBY [0]
Enter 1 if this partition affects the common lobby;
enter 0 if it does not
1*19 ARMS LOBBY [0]
Enter 1 if arming this partition attempts to arm lobby;
enter 0 if it does not
1*20 EXIT ERROR LOGIC [0]
1=Enable (E/E and interior zones will be bypassed if faulted
after exit delay); 0=Disable
1*21 EXIT DELAY RESET [0]
0=No; 1=Resets Exit Delay to 60 seconds after
zone is closed.
FIELDS 1*22-1*25: Allow four sets of two zones each to be
linked so that both must fault within a five minute period to
cause an alarm.
1*22 CROSS-ZONING PAIR ONE | |
1*23 CROSS-ZONING PAIR TWO | |
1*24 CROSS-ZONING PAIR THREE | |
1*25 CROSS-ZONING PAIR FOUR | |
1*28 RF TX LOW BATTERY SOUND [0]
1=immediate; 0=when disarmed; Must be "1" for UL
1*29 RF TX LOW BATTERY REPORT ENABLE [0]
1=enable; 0=disable
Must be "1" for UL
1*30 RF RCVR CHECK-IN INTERVAL [06] |
02-15 times 2 hours; 00 disables supervision
Max. "6" (12 hr) for UL
1*31 RF TRANSMITTER CHECK-IN INTERVAL[12] |
02-15 times 2 hours; 00 disables transmitter supervision
Max. "6" (12 hr) for UL
1*32 RF RECEIVER TYPE [0]
1=4281 ( must have correct revision level); 2=5881
1*33 TOUCH-TONE W/ROTARY BACKUP [0]
1=enable; 0=disable
1*34 COMM. SPLIT REPORT SELECTION [0]
0=no; 1=alarms primary, others secondary;
2=open/close, test secondary, others primary; See *51 for
comments.
ALARM REPORT CODE & ID DIGITS FOR ZONES
65-80 & SUPV. & RESTORE CODES [codes default to zero]
1*35 CODE 1*36 ID 1*37 CODE 1*38 ID 1*39
65 | | 73 | | | Alarm Rst.
66 | | 74 | | | Trouble
67 | | 75 | | | Trble Rst.
68 | | 76 | | | Bypass
69 | | 77 | | | Byps Rstt
70 | | 78 | |
71 | | 79 | |
72 | | 80 | |
NON-ALARM DIALER CODES ( Armed Stay, Time Set & Event Logging)
1*40 First Digit 1*41 Second Digit
Armed STAY | |
Time/Date set or event log reset | |
Event log 50% & 90% full | |
Event log overflow | |
Exit Error (Zone) | |
Exit Error (User) | |
Recent Close | |
1*42 CALL WAITING DEFEAT [0]
1=Yes; 0=No
1*43 PERM. KEYPAD BACKLIGHT [0]
1=enable; 0=disable When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
1*44 WIRELESS KEYPAD [0]
TAMPER DETECT ENABLE 1=enable; 0=disable
1*45 EXIT DELAY SOUNDING [0]
1=enable; 0=disable Produces quick beeping during exit
delay if enabled.
1*46 AUXILIARY OUTPUT MODE [0]
0=ground start; 1=open/close trigger; 2=keypad sounding;
3=AAV trigger
1*47 CHIME ON EXTERNAL SIREN [0]
1=enable; 0=disable
1*48 WIRELESS KEYPAD ASSIGNMENT [0]
0=disable; enter partition in which RF keypad used, 1-8.
1*49 SUPPRESS TX SUPERVISION SOUND [1]
1=disable; 0=enable. Must be "0" for UL.
1*52 SEND CANCEL IF ALARM + OFF [0]
1=no restriction; 0=within Bell Timeout period only
1*53 DOWNLOAD CALLBACK [0]
1=callback not required; 0=callback required; Must be "0" forUL.
1*57 5800 RF BUTTON GLOBAL ARM [0]
Enter "1" to have the system arm/disarm following the button
user's global arm settings. Enter "0" if the button is not to be
used to global arm the system.
1*58 5800 RF BUTTON FORCE ARM [0]
Enter "1" to enable. If a zone is faulted after pressing button,
keypad will beep once. User should press button again within
4 sec. to force arm. Enter "0" to disable.
Must be disabled for UL Listed installations.
1*60 ZONE 5 AUDIO ALARM VERIFICATION [0]
Enter 1 if 2-way audio (AAV) is being used; Enter 0 if it
is not.
1*70 EVENT LOG TYPES
1=enable logging; 0=disable Alrm Chck Byps O/C Systm
1*71 12/24 HOUR TIME STAMP FORMAT [0]
0=12 hour; 1=24 hour
1*72 EVENT LOG PRINTER ON-LINE [0]
0=disable; 1=enable
1*73 PRINTER BAUD RATE 1=300; 0=1200 [0]
1*74 RELAY TIMEOUT XX MINUTES [000] | |
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired
for #80 Menu Mode time driven event relay command numbers
"04/09" and #93 Menu Mode Relay Programming output
command "56".