ADEXANO BACOBAN User manual

25/01/2008 IMP-4000.013A
USER’S MANUAL FOR THE BACOBAN® NEBULISING DEVICE
(230V)
I –PRESENTATION OF THE DEVICE
1 –Power Cable
2 –Drawer with fuse
3 –Extra fuse
4 –Used fuse
5 –Switch for power On/Off
6 –Handle
7 –Button / diffuser head
8 –Diffuser Head
9 –Bottle
10 –Button to activate the spray, “Start /on “
button
11 –Jet
12 –Filtering foam pad
13 –Dosing Selector
Characteristics
Power 1000 W
Voltage 230 V mono+T
Frequency 50 to 60 Hz
Intensity 4,5 A
Maximum Intensity 10 A
Speed of rotation of the turbine 22000 rpm
Capacity of the reservoir 0,5 or 1 liter
Full weight 6,5 kg
Non laden weight (without liquid or bottle) 5,8 kg
Operating temperature 5° to 35°C
Performances
Exit speed of the air 80 m/s
Droplet size 5 microns
Maximal volume to be treated 500 m3
Average output of the liquid 1000 ml/h
II –PRECAUTIONS FOR USE
The manufacturer accepts no responsibility for any material or physical incident which occurs due to incorrect or abnormal
use of the device as indicated in the non restrictive list below:
- Use with products other than those within the Adexano® range.
- Ensure that electric power matches designated standards
- Introduce an object or liquid other than Bacoban into the device at any time
- Move the device conatining BACOBAN® when it contains product . The device should be moved in a horizontal mode.
-Not to check the presence of the jet (11)
- Not to remove the bottle of the BACOBAN® for transportation
The device diffuses a chemical substance, therefore it is necessary to pay attention :
- Not to inhale the product
- Not to smoke near the BACOBAN® while it is working
- Not to place it near a source of ignition
- Humans or animals should not be located in the room during the diffusion process.
25/01/2008 IMP-4000.013A
III –USE
- Remove the head of the diffuser ( 8 ) by pressing on the button ( 7 )
- Screw the cartridge of Bacoban in to the device (1 liter )
- Replace the head of the diffuser in the device
- Connect the device with the electrical network 230/50 Hz with the power cable ( 1 )
- Select, with the button ( 13 ), the volume of the room to be treated (it corresponds to a time of use, check table V)
- Press the switch ( 5 ) to the on position to power up the device.
- Orientate the head ( 8 ) towards zones to be diffused using the handle ( 6 )
- Press on the"Start /On" button ( 14 ,) a buzzer rings for 15 seconds, allowing time to leave the area .
The device stops automatically.
- Wait at least for 10 minutes after the device has stooped functioning before re entering the room
- Press on the switch ( 5 ) to power off the device
== > Disconnect the device and to consult your retailerif a problem occurs.
IV –MAINTENANCE
The device should be kept in a dry and clean place remote from any possible projections.
Change or clean the filtering foam pad if necessary ( 12 )
V –How to use the SELECTOR ( 13 )
1 litre of product = 1 hour of spray = 340m3treated
Volume to be treated in cubic
meters
Spray time in mn
Consumption
20
3,36
60 ml
30
4,44
90 ml
40
6,72
120 ml
50
9
150 ml
60
10,08
180 ml
80
13,44
240 ml
100
18
300 ml
200
36
600 ml
300
54
900 ml
EMERGENCY STOP
The device can be stopped at any time by activating the “on/ off “button (5)
IN CASE OF MALFUNCTION
The device does not start and the light on the On/Off switch (5 ) is not illuminated :
- Verify the power of your electrical network
- Verify the fuse ( 4 ) behind of the device (you have an extra fuse (3) in the same drawer)
The device works but does not disperse the product:
- Verify that the jet ( 11 ) is not blocked
Please contact us if you have any questions relating to the functioning of the unit
+49 6821 9 12 77 60
Distributed by ADEXANO® Spezialprodukte für Gesundheit, Pflege und Prävention GmbH
Produced by AIREL - ZA des Grands Godets - 917 rue Marcel Paul - F 94508 Champigny sur Marne Cedex.
Tél : +49 6821 9 12 77 60 - Fax +49 6821 9 12 77 79

Popular Medical Equipment manuals by other brands

SYMPLUS T1032 R manual

SYMPLUS

SYMPLUS T1032 R manual

Guardian MST55 Use & care instructions

Guardian

Guardian MST55 Use & care instructions

Drive 13049SV Assembly instructions

Drive

Drive 13049SV Assembly instructions

Shukla Medical Xtract-All Maxi Surgical Technique Guide

Shukla Medical

Shukla Medical Xtract-All Maxi Surgical Technique Guide

HeartWare Ventricular Assist System Instructions for use

HeartWare

HeartWare Ventricular Assist System Instructions for use

NRS Healthcare P64090 User instructions

NRS Healthcare

NRS Healthcare P64090 User instructions

Olympus ORBEYE OME-V200 instructions

Olympus

Olympus ORBEYE OME-V200 instructions

Delfi PTS ii Operator and  maintenance manual

Delfi

Delfi PTS ii Operator and maintenance manual

laerdal SimPad PLUS Wi-Fi SETUP

laerdal

laerdal SimPad PLUS Wi-Fi SETUP

Otto Bock Malleo Arexa manual

Otto Bock

Otto Bock Malleo Arexa manual

CME America BodyGuard  323 Clinician Quick Reference

CME America

CME America BodyGuard 323 Clinician Quick Reference

Nidek Medical NT-2000 Operator's manual

Nidek Medical

Nidek Medical NT-2000 Operator's manual

Intelect 2778 Service manual

Intelect

Intelect 2778 Service manual

medi travel women Instructions for use

medi

medi travel women Instructions for use

Envitec OxiQuant B Instructions for use

Envitec

Envitec OxiQuant B Instructions for use

CARITAL NeoICU user guide

CARITAL

CARITAL NeoICU user guide

Erbe 20193-008 Notes on Use

Erbe

Erbe 20193-008 Notes on Use

hinor POCA06-5L manual

hinor

hinor POCA06-5L manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.