ADJ Products, LLC  -  www.adj.com  - Vizi Hybrid 16RX Instruction Manual Page 12
Power Supply:  The  ADJ®  Vizi  Hybrid  16RX  contains  a  electronic 
ballast, which will auto sense the voltage when it is plugged into the 
power  source. With  the  electronic ballast  you  do  not  need  to  worry 
about wall voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers.  A  DMX 
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture 
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 
fixtures (most controllers only have a DATA “OUT” terminal). 
DMX Linking: DMX  is  a  language  allowing  all  makes  and  models 
of  dierent  manufactures  to  be  linked  together  and  operate  from  a 
single  controller,  as  long  as  all  xtures  and  the  controller  are  DMX 
compliant. To  ensure  proper  DMX  data  transmission,  when  using 
several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 
Operation): The  Vizi  Hybrid  16RX  can  be  controlled  via  DMX-512 
protocol. The  Vizi Hybrid  16RX  is  a 19 channel DMX unit. The DMX 
address is set electronically using the controls on  the front panel  of 
the unit. Your unit and your DMX controller require 
a approved DMX-512 110 Ohm Data cable for data 
input and data output (Figure 1).  We recommend 
Accu-Cable  DMX  cables.  If  you  are  making  your 
own cables, be sure to use standard 110-120 Ohm 
shielded  cable  (This  cable  may  be  purchased  at 
almost all professional sound and lighting stores). 
Your  cables  should  be  made  with  a  male  and 
female XLR connector on either end of the cable. 
 Vizi Hybrid 16RX DMX Set Up
Figure 1
Also remember that DMX cable must be daisy chained and cannot be 
split.
 Vizi Hybrid 16RX DMX Set Up
Notice: Be sure to follow gures two and three when making your own 
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces  signal  errors  and
avoids  signal  transmission  problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN  3  (DMX  +) of the  last  fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OT
3-PIN XLR
Figure 2
Figure 3
1 Ground 1 Ground
XLR Male Socket XLR Pin Conguration
3 Hot
2 Cold 2 Cold
3 Hot
XLR Female Socket
Pin 3 = Data True (positive)
Pin 2 = Data Compliment (negative)
Pin 1 = Ground
Special Note: Line Termination.
 When  longer  runs  of  cable  are 
used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ part  number  Z-DMX/T)  will  decrease the  possibilities  of erratic 
behavior. 
DMX512 IN
3-PIN XLR
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
DMX512
DMX+,DMX-,COMMON
1
2
3
Termination reduces  signal  errors  and
avoids  signal  transmission  problems
and interference. It is always advisable
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN  3  (DMX  +) of the  last  fixture.
1
2
3
1
2
3
DMX +
DMX -
COMMON
DMX512 OT
3-PIN XLR
Figure 4
ADJ Products, LLC  -  www.adj.com  - Vizi Hybrid 16RX Instruction Manual Page 13