4 Section 61212075L1-5, Issue 3 61212075L1-5C
If CPE, (e.g. DS3 multi lexer), is within 225 line feet
of the NIU3, enable LBO on SW2-2.
• SW2 Position 2 – ON, LBO toward customer
enabled
• SW2 Position 2 – OFF, LBO toward customer
disabled
LED Indication
Four LEDs on the NIU3 front anel show status
during normal, roblem, and test o eration. Table 1
describes LED indication.
Initiating Loopback with SW1
Front anel LBK SEL ushbutton (SW1) controls
loo back mode as described here:
• To initiate a loo back, de ress SW1 for 5
seconds. During this time the LBK LED flashes
indicating the loo back is “arming.” After 5
seconds the loo back enables, the LED turns ON
solid, and SW1 can be released.
If SW1 is released before the arming eriod ex ires
the loo back does not initiate. This rocess decreases
the chance of an inadvertent loo back.
• If a loo back is in affect, de ressing SW1 will
disable the loo back regardless of initiation
oint.
Loo back riority is in res onse to the most recent
local or remote in ut. The LBK LED shows status.
3. TURNUP
When inserted into a host with ower, the PWR LED
turns ON red while the NIU3 erforms a self-test
during which the remaining LEDs go through an ON/
OFF sequence. If the self-test asses, the PWR LED
turns ON green indicating the NIU3 is online. If the
test fails, the LED remains red and the host by ass
relays will maintain data flow around the NIU3.
4. OPERATION
During normal o eration the NIU3 is trans arent to
the network. In the event of circuit trouble, test
equi ment at the central office can monitor the loo .
When a loo back is initiated, the transmit/receive
aths can be tested to the customer interface. The
NIU3 troubleshooting tests are intrusive to data
transmission.
Monitoring
Front anel mid-size monitoring jacks rovide
nonintrusive monitoring access through a
high-im edance bridging circuit. The monitor level is
nominally 21.5 dB below the signal ower. The signal
from the network is monitored via the NTWK MON
jack; the signal from the customer is monitored via the
CUST MON jack.
Loss of Signal
In the event of a loss of signal, the NIU3 rovides
both a “kee alive” signal and LED notification.
• If there is no signal resent from the network, the
NTWK LED turns ON red and the NIU3 will
transmit an unframed all ones signal toward the
customer.
• If there is no signal resent from the customer,
the CUST LED turns ON red and the NIU3 will
transmit a framed DS3 idle signal toward the
network.
Table 1. LED Indication
DELroloCsutatSnoitpircseD
RWP
neerG
deR
NO
NO
FFO
.noitarepolamroN
.noitcnuflaMdraC
.rewopoN
KWTN deRNO
FFO
.ecafretnikrowtentalangis3SDoN
.ecafretnikrowtentatneserplangis3SD
TSUC deRNO
FFO
.ecafretniremotsuctalangis3SDoN
.ecafretniremotsuctatneserplangis3SD
KBL
wolleYgnihsalF
NO
FFO
.gnimrakcabpooL
.delbanekrowtendrawotkcabpooL
.delbasidkrowtendrawotkcabpooL
.noitcnuflammetsysrehtoro,rewoponsetacidniFFOsDELllA:etoN