ADTRAN 3192 H4TU-C User manual

3192 H4TU-C
1222404L1
DSX
/DS1
ALM
DSL 1
DSL 2
R
S
2
3
2
LBK
ESF
/SF
B8ZS
/AMI
H TUC
TX
RX
TX
RX
DSX MON
DSX EQ
3192 H4TU-C
CLEI: T1L56YSC_ _
LED STATUS
DSL1/DSL2 ●Green Loop 1/ Loop 2 synchronization achieved and signal is present.
No errors currently detected, and SNR margin ≥3 dB.
●Red Loop 1/ Loop 2 synchronization not achieved, in sync with errors,
or SNR margin < 3 dB.
DSX ●Green DSX-1 signal present and no errors currently detected.
●Red In framed mode, denotes loss of framing or loss of sync at the
DSX-1 input. In unframed mode, denotes loss of signal DSX-1
input.
ALM ●●Off No T1 alarms are active.
●Red Loss of DSX-1 signal from the network.
●Yellow Loss of DS1 signal from the CPE.
ESF/SF ●●Off Unit has detected Unframed data.
●Yellow Unit has detected ESF framing data.
●Green Unit has detected SF framing data.
B8ZS/AMI ●Yellow Unit has detected B8ZS line coding data.
●Green Unit has detected AMI line coding data.
LBK ●●Off No local loopbacks active.
●Yellow Local loopback active.
DSX EQ SPLITTING JACKS
TX DSX-1 transmit toward the local loop (intrusive)
RX DSX-1 receive from the local loop (intrusive)
DSX MONITOR JACKS
TX DSX-1 transmit toward the local loop (nonintrusive)
RX DSX-1 receive from the local loop (nonintrusive)
COMPLIANCE
WARNING: Up to –200 VDC might be present on telecommunications wiring. Ensure chassis
ground is properly connected. The DSX-1 interface is intended for connection to
intra-building wiring only.
This product is intended for installation in restricted access locations only and in equipment
with a Type “B” or “E” enclosure.
This product provides span powering voltage (negative only with respect to ground, –190 VDC
nominal, GFI protection < 5 mA) and meets all requirements of Bellcore GR-1089-CORE (Class A2),
and ANSI T1.418-2002. This product is NRTL Listed to the applicable UL standards.
POWERING MODE
The H4TU-C provides –190 VDC span powering voltage and will provide powering to the H4Rs
and the H4TU-R. The –190 VDC span powering voltage is provided on Loop 2.
■ For a complete Installation and Maintenance Practice (P/ 61222404L1-5): 877-457-5007, Faxback Document 885. Please have your fax number ready. ■
C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
utCode I put Output
Power Code (PC) F C
Telecommunication Code (TC) – X
Installation Code (IC) A –
1
2
3
4
5
6
7
8
9
10
A
B
C
D
E
F
H
J
K
L
R1 Rx DSX (Out to DSX)
R Tx DSX (In from DSX)
GND
R1 HDSL4 Loop 2
—48V
R HDSL4 Loop 1
T Tx DSX (In from DSX)
T1 Rx DSX (Out to DSX)
RCV LOS (to Alarm Module)
T1 HDSL4 Loop 2
Frame Ground
T HDSL4 Loop 1
Fuse Alarm (to Alarm Module)
H4TU-C EDGE CONNECTOR WIRING
JOBAID
61222404L1-22D
0311
#61222404L1-22D#
DEFAULT PROVISIONING VALUES
Provisio i g Optio s Optio Setti gs Default Setti gs
1. DSX-1 Line Build Out 0-133 Feet 0-133 Feet
133-266 Feet
266- 399 Feet
399-533 Feet
533-655 Feet
2. DSX-1/DS1 Line Code AMI, B8ZS B8ZS
3. DSX-1/DS1 Framing SF, ESF, Unframed, Auto ESF
4. Forced Frame Conversion Enabled, Disabled Disabled
5. Smartjack Loopback Enabled, Disabled Enabled
6. Loopback Timeout one, 120 Minutes 120 Minutes
7. Latching Loopback Mode T1 (Disabled), FT1 (Enabled) T1 (Disabled)
8. DS1 TX Level 0 dB, –7.5 dB, –15 dB –7.5 dB
9. Span Power Enabled, Disabled Enabled
10. Customer Loss Indicator AIS, AIS/CI, Loopback AIS/CI
11. PRM Setting one, SPRM, PRM, Auto Auto
12. Loop Atten Alarm Threshold 0 (Disabled) 34 dB
1-99 dB
13. S R Margin Alarm Threshold 0 (Disabled) 4 dB
1-15 dB
14. Remote Provisioning Enabled, Disabled Enabled
HDSL4 TROUBLESHOOTING GUIDE
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtra .com
61222404L1-22D
LOOPBACK AND CONTROL CODES
Patter Descriptio Requires Armi g?
1in3 Loop down all units and disarm. o
2in5 Arming Pattern, H4TU-R will loop up if Smartjack LB is enabled. o
3in5 Disarm and loop down all units. Restores LB TMO after D5D6. o
1in6 etwork Arming Pattern. If Smartjack LB is enabled, HTU-R will loop toward network. o
2in6 H4R LB to etwork. o
3in6 H4R LB to etwork. o
4in6 H4R LB to Customer. o
5in6 H4R LB to Customer. o
3in7 H4TU-R LB to etwork. o
4in7 H4TU-C LB to etwork. o
5in7 H4TU-R LB to Customer. o
6in7 H4TU-C LB to Customer. o
3F1E H4TU-C LB to Customer. o
3F02 H4TU-R LB to Customer. o
3F04 H4R LB to Customer. o
3F06 H4R LB to Customer. o
6767 Disable span powering while present. Yes
9393 Loop down H4TU-C, Repeaters - all loopbacks. Loop down H4TU-R - Cust LB always.
Will only loop down H4TU-R etwork LB if IU is disabled. Does not disarm units if they
are armed. o
C741 H4R #1 loop up pattern. 10 bit error injection. Yes
C742 H4TU-R loop up pattern. 20 bit error injection. Yes
C754 H4R #2 loop up pattern. 200 bit error injection. Yes
D3D3 H4TU-C loop up pattern. 231 bit error injection. Yes
D5D5 Query Loopback Pattern (error injection)
H4TU-C: 231 Errors, H4R #1: 10 Errors, H4R #2: 200 Errors, H4TU-R: 20 Errors o
D5D6 Loopback Timeout Override: Disables LB timeout. Restores original LB timeout when unit
is disarmed. Yes
FF48 FDL Arming Pattern (ESF only). Arms all units, H4TU-R will LB to etwork if IU Enabled
(if pattern sources at network). o
FF24 FDL Disarm Pattern (ESF only). Loop down and disarm all units o
FF1E H4TU-C LB to etwork. Will not loop up H4TU-C if H4TU-C already in LB to Customer. o
FF02 H4TU-R LB to etwork. Will not loop up H4TU-R if any unit already in LB to Customer. o
FF04 H4R LB to etwork. o
FF06 H4R LB to etwork. o
WARRANTY
ADTRAN will replace or repair this product within the warranty period if it does not meet its published
specifications or fails while in service. Warranty information can be found at
www.adtran.com/warranty. U.S. and Canada customer Faxback: 877-457-5007, Document 414.
ADTRAN HDSL4 equipment is designed with troubleshooting-at-a-glance features. The following information provides
suggestions for troubleshooting as a result of LED indications which are indicative of loop trouble.
NOTE: Pressing “ESC”while on any screen will go back to the previous screen.
INDICATIONS AND POSSIBLE CAUSES
DSL LED Red
Connect a terminal or PC to the RS-232 (DB-9) craft interface on the front panel. The terminal must be VT100 or compatible
and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit, no flow control. Select “3”from the ADTRAN HDSL4 Main Menu
screen and “1”from the Span Status Screen. Verify the following conditions on the HDSL4 and T1 Detailed Status Screen:
■Margin ≥3 dB
■Attenuation ≤35 dB (1st segment)
Attenuation ≤31 dB (2nd segment)
■No ES, SES, or UAS (Performance History Screen, Main
Menu Selection 5)
If the above conditions do exist, the circuit should provide
quality service; however, if any of the above conditions do not
exist, a cable problem or excessive loss situation is probable,
and more detailed cable testing should be done to verify all
HDSL4 loop specifications are met. These conditions may also
reflect intermittent cable faults or excessive noise impairments.
If intermittent faults or noise impairments are suspected, review
the Performance History Screen.
HDSL4 DEPLOYMENT GUIDELINES
The guidelines provided below apply to the segments of an
HDSL4 circuit, as follows:
1st segment = between the H4TU-C and H4R
2nd segment = between two H4Rs or single H4R and H4TU-R
3rd segment = between the second H4R and the H4TU-R
These deployment guidelines provide the basics for HDSL4 circuit provisioning. If these parameters are met, then the circuit
will provide quality service. If not, a cable problem or excessive loss situation is probable. In this case, a more detailed cable
analysis is required to ensure that all HDSL4 loop specifications are met. These conditions may also be the result of
intermittent cable faults or intermittent noise impairments. If intermittent problems are suspected, utilize the Performance
History screen to assist in troubleshooting.
1. All loops are nonloaded only
2. Any single bridged tap is limited to 2 kft.
3. Total bridged tap length is limited to 2.5 kft.
4. Bridge tap within 1000 feet of units may affect performance of the
circuit
5. Margin ≥6 dB (Detailed Status Screen)
6. No ES, SES, or UAS (Performance History Screen)
7. Foreign Voltage DC (t-r, t-g, r-g) < 3 VDC
8. Insulation Resistance (t-r, r-g, t-g) > 3.5 MΩ
9. Impulse Noise ≤–40 dBmF (measured with an F filter)
10. Wideband Noise ≤–54 dBmF
11. Longitudinal Noise (Power Influence) < 80 dBrnC OK
80–90 dBrnc Marginal
> 90 dBrnc Unacceptable
NOTE: The insertion loss reading shown on the Detailed Status
Screen is an approximation that is valid for some loops.
Exercise caution when using this value.
Ra ge Limits: 26 Gauge / 70ºF / PIC
Recomme ded Maximum
(DSL Assista t Gree Zo e)
1st segment 10.8 kft.
2nd/3rd segment 10.55 kft.
Ra ge Limits: 24 Gauge / 70ºF / PIC
Recomme ded Maximum
(DSL Assista t Gree Zo e)
1st segment 15.25 kft.
2nd/3rd segment 15.05 kft.
Atte uatio Limits
Recomme ded Maximum
(DSL Assista t Gree Zo e)
Upstream Dow stream
1st segment 31 dB 33 dB
2nd/3rd segment 30 dB 30 dB
NOTE: In three segment circuits (two H4Rs), individual
segment resistance values must be verified. Refer
to the HDSL4 Deployment Guidelines section of
the Installation and Maintenance Practice
(P/N 61222404L1-5x) for those guidelines.

Other manuals for 3192 H4TU-C

2

Other ADTRAN Network Card manuals

ADTRAN AHT1U User manual

ADTRAN

ADTRAN AHT1U User manual

ADTRAN 850 DSX-1 User manual

ADTRAN

ADTRAN 850 DSX-1 User manual

ADTRAN 3000 NTU-8 Instruction Manual

ADTRAN

ADTRAN 3000 NTU-8 Instruction Manual

ADTRAN ATLAS 800 Series Module Nx56/64 Bonding User manual

ADTRAN

ADTRAN ATLAS 800 Series Module Nx56/64 Bonding User manual

ADTRAN AHDSL2 Instruction Manual

ADTRAN

ADTRAN AHDSL2 Instruction Manual

ADTRAN NetVanta 8044M User manual

ADTRAN

ADTRAN NetVanta 8044M User manual

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN 3192 H2TU-C User manual

ADTRAN

ADTRAN 3192 H2TU-C User manual

ADTRAN Total Access 1500 Instruction Manual

ADTRAN

ADTRAN Total Access 1500 Instruction Manual

ADTRAN DDM+ H2TU-C Instruction Manual

ADTRAN

ADTRAN DDM+ H2TU-C Instruction Manual

ADTRAN 239 T1 HDSL4 Instruction Manual

ADTRAN

ADTRAN 239 T1 HDSL4 Instruction Manual

ADTRAN 5000 Series Operating manual

ADTRAN

ADTRAN 5000 Series Operating manual

ADTRAN 1000 239 HRE User manual

ADTRAN

ADTRAN 1000 239 HRE User manual

ADTRAN DS3 User manual

ADTRAN

ADTRAN DS3 User manual

ADTRAN ATLAS 550 User manual

ADTRAN

ADTRAN ATLAS 550 User manual

ADTRAN NetVanta Internet-Based WAN Backup User manual

ADTRAN

ADTRAN NetVanta Internet-Based WAN Backup User manual

ADTRAN TRACER 6000 SERIES User guide

ADTRAN

ADTRAN TRACER 6000 SERIES User guide

ADTRAN 900 Series User manual

ADTRAN

ADTRAN 900 Series User manual

ADTRAN TRACER Protection Switch User manual

ADTRAN

ADTRAN TRACER Protection Switch User manual

ADTRAN OPTI-6100 LMX User manual

ADTRAN

ADTRAN OPTI-6100 LMX User manual

ADTRAN U-BR1TE User manual

ADTRAN

ADTRAN U-BR1TE User manual

ADTRAN Type 400 Instruction Manual

ADTRAN

ADTRAN Type 400 Instruction Manual

ADTRAN 3.125 Gigabit Ethernet User manual

ADTRAN

ADTRAN 3.125 Gigabit Ethernet User manual

ADTRAN NetVanta 1000R Series Operating manual

ADTRAN

ADTRAN NetVanta 1000R Series Operating manual

Popular Network Card manuals by other brands

TP-Link TL-PA4020 Quick installation guide

TP-Link

TP-Link TL-PA4020 Quick installation guide

Cisco IDTA153 installation manual

Cisco

Cisco IDTA153 installation manual

NETGEAR DG814 - DSL Modem Internet Gateway Reference manual

NETGEAR

NETGEAR DG814 - DSL Modem Internet Gateway Reference manual

TRENDnet TEW-642EC Quick installation guide

TRENDnet

TRENDnet TEW-642EC Quick installation guide

Dynex DX-NNBC - N NOTEBOOK CARD WiFi user guide

Dynex

Dynex DX-NNBC - N NOTEBOOK CARD WiFi user guide

SyChip WLAN6065SD user manual

SyChip

SyChip WLAN6065SD user manual

PC LINE PCL-PCI10 quick start guide

PC LINE

PC LINE PCL-PCI10 quick start guide

NexWatch PW-5000 PW5K1EN installation manual

NexWatch

NexWatch PW-5000 PW5K1EN installation manual

National Instruments NI 9478 operating instructions

National Instruments

National Instruments NI 9478 operating instructions

Allwins AWU50G-W user manual

Allwins

Allwins AWU50G-W user manual

Dynex DX-NNBC - N NOTEBOOK CARD WiFi Quick install guide

Dynex

Dynex DX-NNBC - N NOTEBOOK CARD WiFi Quick install guide

Gtran Wireless DotSurfer GPC-2100 user manual

Gtran Wireless

Gtran Wireless DotSurfer GPC-2100 user manual

Sierra Wireless AirCard 880 Wireless Modem quick start guide

Sierra Wireless

Sierra Wireless AirCard 880 Wireless Modem quick start guide

CSL 300149 user manual

CSL

CSL 300149 user manual

Sonnet PRESTO GIGABIT quick start guide

Sonnet

Sonnet PRESTO GIGABIT quick start guide

ICP DAS USA ZT-2018/S quick start

ICP DAS USA

ICP DAS USA ZT-2018/S quick start

Hawking HGU1 Quick installation guide

Hawking

Hawking HGU1 Quick installation guide

3Com 3C589D user guide

3Com

3Com 3C589D user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.