C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
DS3
DS3 NIU MTC
P/N 1212071L1
CLEI: NCC1SN0D
DS3 NIU Monitor and Test Card
NIU3
1212071
ONLINE
IN TO NTWK
OUT FROM
NTWK
NTWK TO CUST
MON
IN TO CUST
OUT FROM
CUST
CUST TO NTWK
MON
ENVIRONMENTAL SPECIFICATIONS
♦Operating temperature: –40°C to +70°C
♦Storage temperature: –40°C to +85°C
♦Relative humidity: 95% noncondensing maximum
COMPLIANCE
♦NEBS Level 3
♦Meets FCC Part 15, Class A Requirements
♦Meets UL 60950 Requirements
The following table shows the compliance codes for the DS3 Monitor and
Test Card. The DS3 Monitor and Test Card is NRTL listed to the applicable
UL standards.
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
NOTE: Changes or modifications not expressly approved by ADTRAN could void
authority to operate this equipment.
Compliance Code Input Output
Power Code (PC) F –
Telecommunication Code (TC) – –
Installation Code (IC) A –
GENERAL
This job aid provides instructions for using the ADTRAN DS3 NIU Monitor
and Test Card (DS3 NIU MTC) to provide a quick, reliable means for craft
personnel to monitor and test both the network side and customer side data
loops. The DS3 MTC is compatible with any DS3 NIU3 chassis:
♦DS3 NIU Single Slot Housing
♦DS3 NIU 3-Slot Shelf
♦DS3 NIU 12-Slot Shelf
Digital Network Loopback Test
The DS3 MTC inserts into any empty slot in the DS3 NIU chassis desig-
nated for test. There are six front panel midsize connectors labeled as shown:
♦NTWK TO CUST MON
♦OUT FROM NTWK
♦IN TO NTWK
♦CUST TO NTWK MON
♦OUT FROM CUST
♦IN TO CUST
The OUT FROM X test jacks receive network or customer data entering the
DS3 MTC and pass that data to the test device. The IN TO X test jacks inject
network or customer test signals from the test device into the DS3 MTC for
transmission into the respective loop. The MON jacks monitor the network-
to-customer or customer-to-network loop.
A green ONLINE status LED verifies that the card has ±24 VDC or
–48 VDC applied, and the cut-through relays are energized. If the LED is
off, the card does not have power, and the cut-through relays are de-ener-
gized. Cut-through relays are mounted separately on the housing, not on the
DS3 MTC.
The DS3 MTC is not intrusive during monitoring functions but is intrusive
and will disrupt data flow during testing functions.
INSTALLATION
After unpacking the unit, inspect it for damage. If damage is noted, file a
claim with the carrier, and then notify ADTRAN. See Warranty section.
Insert the card in the empty slot designated for test. Ensure the edge connec-
tor seats firmly into the backplane. Secure the card in place with the thumb-
screws.
61212071L1-22C