AEMC 5070 User manual

MEGOHMMETER 5070
ENGLISH User Manual

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: 2130.30
Model #: 5070
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.aemc.com

Megohmmeter Model 5070
1
Table of Contents
1. INTRODUCTION ................................................................................. 4
1.1 International Electrical Symbols...........................................................5
1.2 DenitionofMeasurementCategories.................................................5
1.3 ReceivingYourShipment.....................................................................5
1.4 OrderingInformation ............................................................................6
1.4.1 AccessoriesandReplacementParts......................................6
1.5 AccessoryInformation..........................................................................6
1.5.1 DataView®Software................................................................6
2. PRODUCT FEATURES......................................................................... 7
2.1 ControlFeatures ..................................................................................8
2.2 DisplayFeatures ................................................................................10
3. SPECIFICATIONS............................................................................. 11
3.1 ReferenceConditions.........................................................................11
3.2 Voltage ...............................................................................................11
3.3 InsulationResistance.........................................................................11
3.4 PowerSupply.....................................................................................16
3.5 EnvironmentalSpecications.............................................................17
3.6 MechanicalSpecications..................................................................17
3.7 SafetySpecications..........................................................................17
3.8 VariationsinOperatingRange ...........................................................18
4. SPECIAL FUNCTIONS....................................................................... 19
4.1 SET-UPFunction ...............................................................................19
4.1.1 DefaultCongurations ..........................................................19
4.1.2 InstrumentCongurationParameters...................................20
4.1.3 SET-UPMenu .......................................................................27
4.2 MODE/PRINTButton .......................................................................28
4.2.1 PrimaryFunction-MODE.....................................................28
4.2.2 SecondaryFunction-PRINT................................................32

2
Megohmmeter Model 5070
4.3 DISPLAY/GRAPHButton .................................................................33
4.3.1 PrimaryFunction-DISPLAY.................................................33
4.3.2 SecondaryFunction-GRAPH..............................................46
4.4 Left/TEMPButton.............................................................................46
4.4.1 PrimaryFunction-Left.........................................................46
4.4.2 SecondaryFunction-TEMP.................................................46
4.5 Down/SMOOTHButton....................................................................48
4.5.1 PrimaryFunction-Down ......................................................48
4.5.2 SecondaryFunction-SMOOTH...........................................48
4.6 Up/ALARMButton ............................................................................49
4.6.1 PrimaryFunction-Up...........................................................49
4.6.2 SecondaryFunction-ALARM...............................................49
4.7 Right/BacklightButton......................................................................49
4.7.1 PrimaryFunction-Right .......................................................49
4.7.2 SecondaryFunction-Backlight ............................................49
4.8 MEM/MRButton ...................................................................50
4.8.1 PrimaryFunction-MEM(Save)............................................50
4.8.2 SecondFunction-MR(Recall).............................................51
4.9 ClearingtheMemory..........................................................................52
4.10 CalculationofΔTfromStoredData....................................................53
4.11 MaximumOutputVoltage...................................................................54
4.12 ListofErrorCodes .............................................................................54
5. MEASUREMENT FUNCTIONS ........................................................... 55
5.1 AC/DCVoltage ...................................................................................55
5.2 InsulationMeasurement.....................................................................55
5.3 CapacitanceMeasurement ................................................................58
5.4 ResidualCurrentMeasurement .........................................................58
6. OPERATION..................................................................................... 59
6.1 PerformingMeasurements.................................................................59
6.2 StepFunctionMode...........................................................................60
6.3 OperationExamples...........................................................................62

Megohmmeter Model 5070
3
6.4 PrintingMeasuredValues(MODE/PRINTButton)....................64
6.5 InstantaneousPrintingofMeasurements(PrintResult)................64
6.6 PrintingDatainMemory(PrintMemory) ....................................67
7. DATAVIEW®SOFTWARE................................................................... 71
7.1 InstallingDataView®...........................................................................71
7.2 ConnectingtheModel5070toyourComputer ..................................75
7.3 EstablishingCommunicationtotheInstrument..................................75
7.4 ConguringtheInstrument.................................................................76
7.5 RunningtheTest ................................................................................79
7.6 ExportingtheReporttoaPDFFile ..................................................82
7.7 DataView®MegohmmeterTemplates.................................................83
7.7.1 MegohmmeterSummaryReportTemplate ...........................83
7.7.2 TitlePage..............................................................................84
8. MAINTENANCE................................................................................ 85
8.1 RechargingtheBattery ......................................................................85
8.2 FuseReplacement.............................................................................86
8.3 Cleaning.............................................................................................86
8.4 Storage...............................................................................................86
APPENDIX A: UTILIZING THE GUARD TERMINAL.................................. 87
APPENDIX B: SERIAL CABLE REQUIREMENTS ..................................... 89
APPENDIX C: V DISTURBANCE/V OUTPUT FEATURE............................ 90
RepairandCalibration.................................................................................91
TechnicalandSalesAssistance ..................................................................91
LimitedWarranty .........................................................................................92
WarrantyRepairs ........................................................................................92

4
Megohmmeter Model 5070
CHAPTER 1
INTRODUCTION
WARNING
Thesesafetywarningsareprovidedtoensurethesafetyofpersonnel
andproperoperationoftheinstrument.
• Donotattempttoperformanytestswiththeseinstrumentsuntil
youhavereadtheinstructionmanual.
• Safetyistheresponsibilityoftheoperator!
• Tests are to be carried out only on non-energized circuits!
Checkforlivecircuitsbeforemakingresistancemeasurements
(SafetyCheck).
• High voltage is present, as is the sample connected to it.
Anyoneperformingorassistingintestingmustfollowallsafety
precautions to prevent electrical shock to themselves and to
others.
• AEMC®considerstheuseofrubberglovestobeanexcellent
safetypractice,eveniftheequipmentisproperlyoperatedand
correctlygrounded.
• Whentestingsampleswithacapacitivecomponent,makesure
they have been properly discharged and are safe to touch.
Dielectric insulation samples should be short-circuited for at
leastvetimestheamountoftimetheywereenergized.
• Megohmmetersshouldneverbeusedinanexplosiveenviron-
ment.
• Onlyusetheleadsthataresuppliedwiththemegohmmeter.If
theyaredefectiveorworn,replacebeforetesting.
• Thisinstrumentcanbeusedoninstallationsrated for 1000V
CATIIIor2500VCATI.

Megohmmeter Model 5070
5
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or reinforced
insulation.
This symbol on the instrument indicates a WARNING and that the operator must refer
to the user manual for instructions before operating the instrument. In this manual,
the symbol preceding instructions indicates that if the instructions are not followed,
bodily injury, installation/sample and product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may be
dangerous.
In conformity with WEEE 2002/96/EC
1.2 Definition of Measurement Categories
CAT II: For measurements performed on circuits directly connected to the
electricaldistributionsystem.Examplesaremeasurementsonhousehold
appliancesorportabletools.
CAT III: Formeasurementsperformedinthebuildinginstallationatthedistribution
level such as on hardwired equipment in xed installation and circuit
breakers.
CAT IV: Formeasurementsperformedattheprimaryelectricalsupply(<1000V)
suchasonprimaryovercurrentprotectiondevices,ripplecontrolunits,
or meters.
1.3 Receiving Your Shipment
• Matchthecontentswiththeorderinginformation.
• Notifyyourdistributorofanymissingitems.
• If the equipment appears to be damaged, le a claim immediately with the
carrierandnotifyyourdistributoratonce.
NOTE: Charge the instrument fully before use.

6
Megohmmeter Model 5070
1.4 Ordering Information
Megohmmeter Model 5070.............................................................Cat. #2130.30
Includes extra large tool bag, set of three 10 ft (5kV) leads (red/black/blue) with integral
hippo clips (5000V), one guard terminal jumper lead, RS-232 DB9 F/F 6 ft null modem cable,
RS-232 to USB adapter, US 115V power cord, rechargeable battery pack, and a USB stick
with DataView®software and user manual.
1.4.1 Accessories and Replacement Parts
Cable,PCRS-232,DB9F/F6ftNullModemCable........................ Cat. #2119.45
Setof3,color-coded10ftsafetyleads(5000V),3color-coded
alligatorclips(600VCATIV)............................................................. Cat. #2119.76
Lead–Replacement1ftjumperlead............................................... Cat. #2119.78
Fuse,setof3,0.1A,380V,5x20,.10kA ......................................... Cat. #2119.84
ReplacementLead–Setof3,Color-coded10ft(5kV)Safetywith
IntegralHippoClips(JUMPER LEAD INCLUDED) .................................... Cat. #2119.85
Lead–Setof3,Color-coded25ft(5kV)Safetywith
IntegralHippoClips(JUMPER LEAD NOT INCLUDED) ............................. Cat. #2119.86
Lead–Setof3,Color-coded45ft(5kV)Safetywith
IntegralHippoClips(JUMPER LEAD NOT INCLUDED) ............................. Cat. #2119.87
ExtraLargeClassicToolBag ...........................................................Cat. #2133.73
Inverter–12VDC to 120VAC200WattforVehicleuse......................Cat. #2135.43
Battery–Rechargeable9.6V ...........................................................Cat. #2960.21
US115VPowerCord .......................................................................Cat. #5000.14
Adapter–RS-232toUSB2.0 ..........................................................Cat. #5000.60
1.5 Accessory Information
1.5.1 DataView®Software
DataView®softwaremakesitpossibleto:
• Retrievedatafrommemoryandplotgraphsofthechangesininsulation
asafunctionofthetimeoverwhichthetestvoltageisapplied,R(t).
• Printoutprotocolsofpersonalizedtests,dependingontheuser’sneeds.
• Createtextlesforuseonspreadsheets.
• SetupandcontroltheinstrumententirelybytheRS-232.

Megohmmeter Model 5070
7
CHAPTER 2
PRODUCT FEATURES
TheModel5070megohmmeterisatop-of-the-linemeasuringinstrument,portable,
inaruggedhousingwithagraphicdisplay.Itiscapableofoperatingfrominternal
batteryorlinepower.
Main Functions:
• Automatic detection and measurement of voltage/frequency/input cur-
rent
• Quantitativeandqualitativeinsulationmeasurement
− Measurement at 500/1000/2500/5000VDC or other test voltage
between 40 and 5100VDC(adjustablevoltage)
− Measurementinvoltagestepmode(theappliedvoltageincreasesin
steps)
− AutomaticcalculationofDAR/PIandDD(dielectricdischargeindex)
qualityratios
− Automaticcalculationofmeasurementresultreferredtoareference
temperature
• Automaticcapacitancemeasurement
• Automaticmeasurementofresidualcurrent
Thismegohmmeterhelpsensurethesafety ofelectrical installationsandequip-
ment. Theoperationis controlled by amicroprocessorfordataacquisition, pro-
cessing,anddisplayofmeasurementsandthestorageandprintingofresults.
Advantages:
• Digitallteringofinsulationmeasurements
• Automaticvoltagemeasurement
• Automatic detection of external AC or DC voltages on the terminals,
beforeorduringinsulationmeasurements,disablingorstoppingthemea-
surementswhenmeasurementaccuracyisnolongerguaranteed
• Thresholdprogrammingtotriggeraudiblealarms
• Timerformeasurementtimechecks
• Fuseprotectionoftheinstrumentwithdetectionanddisplayofdefective
fuses
• Operatorsafetybyautomaticdischargeofresidualhigh voltageonthe
equipmenttested

8
Megohmmeter Model 5070
• Automaticshutdownoftheinstrumenttosavebatterypower
• Batterychargeindication
• Largebacklitgraphicdisplaythatisveryeasytoread
• Memory(128KB),realtimeclock,andserialinterface
• ControlandprogrammingoftheinstrumentfromaPC
(usingDataView®software)
• Directprintingwithaserialprinter(optionalaccessory-Cat.#2140.21)
2.1 Control Features
1
7
2
8
6
4
35
1. Safetyterminals:“+”,“G”and“-”
2. Protectivefuseaccess
3. ACpowerplug(directoperationonACandbatteryrecharge)
4. Back-litliquidcrystaldisplay
5. RS-232serialinterfacemaleplug(9-pin)
• ForconnectiontoaPCorprinter
6. Rotaryselectorswitchwith8positions:
• OFF-Instrumentisoff

Megohmmeter Model 5070
9
• MΩ- 500V-Insulationmeasurement(to2TΩ)
• MΩ- 1000V-Insulationmeasurement(to4TΩ)
• MΩ- 2500V-Insulationmeasurement(to10TΩ)
• MΩ- 5000V-Insulationmeasurement(to10TΩ)
• MΩ50V - 5000V-Insulationmeasurementwithselectabletestvoltage
(from 40V to 5100V: 10V steps from 40V to 1000V and 100V steps
1000Vto5000V)
• Step Voltage -Insulationmeasurementwithvoltagestepfunction(up
to5stepscanbecongured)
• SET-UP-Userprogrammingofthemegohmmeterconguration
7. START/STOPbutton(startsandstopsmeasurements)
8. Eightbuttons, each with a primaryand secondary function.The secondary
functionsarehighlightedinyellowitalicsbeloweachbutton:
• 2nd (yellow button)-Selectsthesecondfunctiononeachbutton.
• -Selectsafunctionorincrementstheparameteronwhichthecursor
ispositioned.Pressingandholdingthekeyincreasestherateofchange
oftheparameter.
ALARM -
ActivatesordeactivatesthealarmsprogrammedinSET-UP.
• -Selectsafunctionordecrementstheparameteronwhichthecursor
ispositioned.Pressingandholdingthekeyincreasestherateofchange
oftheparameter.
SMOOTH-Stops/startssmoothingofdisplayedvaluesduringtesting.
•-Selectsaparametertobemodiedtotheleft.
TEMP - activates temperature correction of the measurement to the
referencetemperatureprogrammedinSET-UP.
• -Selectsaparametertobemodiedtotheright.
-TurnsthedisplaybacklightONorOFF.
• MEM-Savesmeasuredvalues.
MR - Recalls saved data.
• MODE-Beforestartingatest,themodefunctionallowsselectionofrun
time,samplerate,DARPIandratiotimes.
PRINT-directprintingoftestresult(s)onaserialorparallelprinter.
• DISPLAY - Browses through the various screens accessible before,
duringandafterthemeasurement.
• GRAPH-Aftera“timedrun”,theGraphmodedisplaysinsulationresis-
tanceversustimeinagraphformat.

10
Megohmmeter Model 5070
2.2 Display Features
REMOTE IndicatesthattheinstrumentiscontrolledremotelyviatheRS-232
interface.Inthismode,allofthekeysandtherotaryswitchareinac-
tive,exceptfortheOFFposition.
COM Flasheswhendataistransmittedtotheserialinterface.Oncontinu-
ouslyifthereisaproblemintransmission.
2nd Indicatesthatthesecondaryfunctionofakeywillbeused.
Indicatesthatthe“programmedtimetest”modewasselectedbefore
themeasurementwasstarted.
DAR Indicatesthatthe“automaticcalculationofDielectricAbsorption
Ratio”modewasselectedbeforethemeasurementwasstarted.
PI Indicatesthatthe“automaticcalculationofPolarizationIndex”mode
wasselectedbeforethemeasurementwasstarted.
DD Indicatesthatthe“automaticcalculationof“DielectricDischarge
Index”modewasselectedbeforethemeasurementwasstarted.
SMOOTH Smoothstheinsulationmeasurementreadingsonthedisplayfor
better visibility.
ALARM Indicatesthatthealarmisactivated.Anaudiblealarmwillsoundif
thevaluemeasuredisabovethelimitdenedintheSET-UPmode.
Indicatesthebatterychargecondition.
Voltagegenerateddangerous,V>120VDC.
Externalvoltagepresent-thissymbolisactivatedwhentheStart
buttonispressedifV>25VRMS.

Megohmmeter Model 5070
11
CHAPTER 3
SPECIFICATIONS
3.1 Reference Conditions
Influence Quantity Reference Values
Temperature 23°C ±3°K
Relative Humidity 45 to 55%
Supply Voltage 9 to 12V
Frequency Range DC and 15.3 to 65Hz
Capacitance in parallel with the input
resistance 0µF
Electric Field nil
Magnetic Field <40A/m
3.2 Voltage
Measurement Range 1.0 to 99.9V 100 to 999V 1000 to 2500V 2502 to 4000V
Frequency Range* DC and 15Hz to 500Hz DC Only
Resolution 0.1V 1V 2V 2V
Accuracy 1% of Reading ± 5cts 1% of Reading ± 3ct
Input Impedance 750kΩat 3MΩdepending on measure voltage
*Over 500Hz, the small display indicates “- - - -” and the main display gives only an assess-
ment of the peak value of the measured voltage.
Measurement Category:1000VCATIIIor2500VCATI(transients≤2.5kV)
3.3 Insulation Resistance
Method: Voltage-currentmethodaccordingtoEN61557-2(ed.02/97)
Nominal Output Voltage: 500,1000,2500,5000VDC (orselectablefrom40Vto5100V)
Adjustments Available in Variable Mode: 10Vfrom40Vto1000V
100Vfrom1000Vto5100V
Open-circuit Voltage: ≤1.1xVn±2V(Vn± 2%invariablemode)
Max. Overload of Voltage Vn: (1.05+dISt)Vn+50V
withdlSt=3%,10%or20%
NOTE: Vn = Test Voltage

12
Megohmmeter Model 5070
Nominal Current:>1mADC
Short-circuit Current: <1 .6mA±5%
Load Current: 3mADCapproxwhenstartingmeasurement
Maximum Acceptable AC Voltage:
Vpeak-(1.05+dISt)VnwithdlSt=3%,10%or20%
NOTE: dlStistheratioofVDisturbance/VOutputandisselectablein
SET-UPmode
Measurement Ranges:
500V:30kΩto 1.999TΩ 2500V:100kΩto 9.99TΩ
1000V:100kΩto 3.999TΩ 5000V:300kΩto 9.99TΩ
Variable: 40Vto5100V(seegraphbelow)
12
Rmax (T
Ω)
Variable Voltage (V)
Resistance Range in Voltage Mode
10
8
6
4
2
0
0 1000 2000 3000 4000 5000
300
Rmin (kΩ
)
250
200
150
100
50
0
Resolution and Accuracy Chart (seecurves-pages14and15)
Test
Voltage 500V 500V - 1000V
2500V 500V - 1000V - 2500V - 5000V
Range 30 to
99kΩ
100 to
299kΩ
300 to
999kΩ
1MΩto
3.999MΩ
4.00 to
39.99MΩ
40.0 to
399.9MΩ
Resolution 1kΩ10kΩ100kΩ
Accuracy ±5% of Reading + 3cts
Test
Voltage 500V - 1000V - 2500V - 5000V 1000V - 2500V
5000V
2500V
5000V
Range 400MΩto
3.999GΩ
4.00 to
39.99GΩ
40.0 to
399.9GΩ
400GΩto
1.999TΩ2.000 to 3.999TΩ4.00 to
10.00TΩ
Resolution 1MΩ10MΩ100MΩ1GΩ10GΩ
Accuracy ±5% of Reading + 3cts ±15% of Reading + 10cts

Megohmmeter Model 5070
13
DC Voltage Measurement (duringinsulationtest):
Range Resolution Accuracy
40.0 to 99.9V 0.1V
1% of Reading ± 1ct100 to 1500V 1V
1501 to 5100V 2V
DC Voltage Measurement (afterinsulationtest):
Range Resolution Accuracy
25 to 5100V 0.2% Vn 5% of Reading ± 3cts
Typical build-up time for the measurement according to components tested
(Vdist = 0.03Vn).
Thesevaluesincludetheinuencescausedbythechargeofthecapacitivecom-
ponent,bytheautomaticrangesystemandtothetestvoltagecontrol.
Test Voltage Load
Non Capacitive
(unsmoothed
measurement)
With capacitance
of 1µF (smoothed
measurement)
500V 1MΩ3s 4s
100GΩ8s 40s
1000V 1MΩ3s 4s
100GΩ8s 80s
2500V 3MΩ3s 4s
100GΩ8s 90s
5000V 5MΩ4s 16s
100GΩ8s 120s
Typical discharge time for a capacitive component to reach 25VDC.
Initial Voltage 500V 1000V 2500V 5000V
Discharge time (C in µF) C x 3s C x 4s C x 4s C x 7s

14
Megohmmeter Model 5070
Typical changes in test voltages as a function of the load:
0
100
200
300
400
500
600
Output voltage (V)
0.01 0.
11
Resistance (MΩ)
500V Range
0
200
400
600
800
1000
1200
Output voltage (V)
0.01
1
Resistance (MΩ)
1000V Range

Megohmmeter Model 5070
15
0
500
1000
1500
2000
2500
3000
Output voltage (V)
0.1
10
1
Resistance (M
Ω
)
2500V Range
0
1000
2000
3000
4000
5000
6000
Output voltage (V)
0.1
10
1
Resistance (MΩ)
5000V Range

16
Megohmmeter Model 5070
Capacity Measurement (afterdischargeoftestedcomponent):
Range Resolution Accuracy
0.005 to 9.999µF 1nF 10% of Reading ± 1ct
10.00 to 49.99µF 10nF
Leakage Current Measurement
Range Resolution Accuracy
0.000 to 0.250nA 1pA 15% of Reading ± 10cts
0.251 to 9.999nA 10% of Reading
10.00 to 99.99nA 10pA
5% of Reading
100.0 to 999.9nA 100pA
1.000 to 9.999µA 1nA
10.00 to 99.99µA 10nA
100.0 to 999.9µA 100nA
1000 to 3000µA 1µA 10% of Reading
Calculation of Terms DAR and PI
Range Resolution Accuracy
0.02 to 50.00 0.01 5% of Reading ± 1ct
Calculation of Term DD
Range Resolution Accuracy
0.02 to 50.00 0.01 10% of Reading ± 1ct
3.4 Power Supply
• RechargeablebatteryNiMh(8x1.2V/3.5Ah)
• Recharge:85to256V/50-60Hz
Minimum Battery Charge Life(perNFEN61557-2)
Test Voltage Nominal Charge Number of Measurements 5s on nominal charge
(with 25s pause between each measurement)
500V 500kΩ6500
1000V 1MΩ5500
2500V 2.5MΩ4000
5000V 5MΩ1500
Average Battery Life:Theoperatingtimewillbe15daysor3weeks,basedupona
10minutelongPImeasurement.
Recharge Time:
6hoursfor100%capacity(10hoursifthebatteryiscompletelydrained)
0.5hoursfor10%capacity(chargelife:2daysapproximately)

Megohmmeter Model 5070
17
NOTE: It is possible to recharge the batteries while performing insulation
measurements provided that the values measured are higher than 20MΩ.
In this case, the recharging time is higher than 6 hours and depends on
the frequency of the measurements.
3.5 Environmental Specifications
Operating Range:
14°to104°F(-10°to40°C)duringrechargingofbatteries
14°to131°F(-10°to55°C)duringmeasurement
10to80%RH
Storage:-40°to158°F(-40°to70°C);10to90%RH
Altitude:<2000m
3.6 Mechanical Specifications
Case Dimensions (LxWxH):
10.63x9.84x7.09"(270x250x180mm)
Weight:9.5lbs(4.3kg)approx
3.7 Safety Specifications
ElectricalsafetyaccordingtoEN61010-1(Ed.2for2001),
EN61557(ed.97)
Doubleinsulation:
1000V CATIII
2500V CATI
PollutionDegree2
Electromagnetic Compatibility:
NFEN61326-1(Ed.97)+A1,industrialenvironmentcategory
Mechanical Protection:
IP53perNFEN60529(Ed.92)
IK04perNFEN50102(Ed.95)

18
Megohmmeter Model 5070
3.8 Variations in Operating Range
Influential
Quantity
Range of
Influence
Quantity
Influenced*
Influence
Typical Max
Battery
Voltage 9V to 12V V
MΩ
<1ct
<1ct
2cts
3cts
Temperature -10° to +55°C V
MΩ
0.15% R/10°C
0.20% R
0.3% R ± 1ct
1% R ± 1ct
Humidity 10 to 80% RH
V
MΩ(10kΩto 40GΩ)
MΩ(40GΩto 10TΩ)
0.2% R
0.2% R
3% R
1% R ± 2cts
1% R ± 5cts
15% R ± 5cts
Frequency 15 to 500Hz V 0.3% R 0.5% R ± 1ct
AC voltage
superimposed on
test voltage
0% to 20% Vn MΩ0.1% R / % Vn 0.1% R / % Vn ± 5cts
*The terms DAR, PI, DD and the capacity and current leak measurements are included in the quantity “MΩ”.
Other manuals for 5070
1